Vanguard EBDV34N Скачать руководство пользователя страница 2

2

106417

DIRECT-VENT FIREPLACE

®

For more information, visit www.desatech.com

SAFETY
INFORMATION

1.

This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases unless a certified kit
is used.

2.

For propane/LP fireplace, do not place
propane/LP supply tank(s) inside any
structure. Locate propane/LP supply
tank(s) outdoors. To prevent perfor-
mance problems, do not use propane/LP
fuel tank of less than 100 lbs. capacity.

3.

If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do

not use any phone in your building

• immediately call your gas supplier

from a neighbor’s phone. Follow the
gas supplier’s instructions

• if you cannot reach you gas supplier,

call the fire department.

4.

Never install the fireplace
• in a recreational vehicle
• where curtains, furniture, clothing, or

other flammable objects are less than
42" from the front, top, or sides of
the fireplace

• in high traffic areas
• in windy or drafty areas

5.

This fireplace reaches high tempera-
tures. Keep children and adults away
from hot surfaces to avoid burns or cloth-
ing ignition. Fireplace will remain hot
for a time after shutdown. Allow surfaces
to cool before touching.

6.

Carefully supervise young children
when they are in the room with fireplace.

7.

Do not modify this fireplace under any
circumstances. Any parts removed for
servicing must be replaced prior to op-
erating fireplace.

8.

Turn fireplace off and let cool before
servicing, installing, or repairing. Only
a qualified service person should in-
stall, service, or repair this fireplace.
Have fireplace inspected annually by a
qualified service person.

9.

You must keep control compartments,
burners, and circulating air passages
clean. More frequent cleaning may be
needed due to excessive lint and dust
from carpeting, bedding material, pet
hair, etc. Turn off the gas valve and pi-
lot light before cleaning fireplace.

10. Have venting system inspected annu-

ally by a qualified service person. If
needed, have venting system cleaned
or repaired. See Cleaning and Mainte-
nance
, page 26.

11. Keep the area around your fireplace

clear of combustible materials, gaso-
line, and other flammable vapor and
liquids. Do not run fireplace where
these are used or stored. Do not place
items such as clothing or decorations
on or around fireplace.

12. Do not use this fireplace to cook food

or burn paper or other objects.

13. Do not use any solid fuels (wood, coal,

paper, cardboard, etc.) in this fireplace.
Use only the gas type indicated on fire-
place nameplate.

14. This appliance, when installed, must be

electrically grounded in accordance
with local codes or, in the absence of
local codes, with the National Electri-
cal Code, ANS/NFPA 70
, or the Cana-
dian Electrical Code, CSA C22.1
.

15. Do not obstruct the flow of combus-

tion and ventilation air in any way. Pro-
vide adequate clearances around air
openings into the combustion chamber
along with adequate accessibility clear-
ance for servicing and proper operation.

16. Do not install fireplace directly on car-

peting, vinyl tile, or any combustible
material other than wood. The fireplace
must set on a metal or wood panel ex-
tending the full width and depth of the
fireplace.

17. Do not use fireplace if any part has been

exposed to or under water. Immediately
call a qualified service person to ar-
range for replacement of the unit.

18. Do not operate fireplace if any log is

broken.

19. Do not use a blower insert, heat ex-

changer insert, or other accessory not
approved for use with this fireplace.

20. Do not operate fireplace with glass door

removed, cracked, or broken.

IMPORTANT: Read this owner’s
manual carefully and completely
before trying to assemble, oper-
ate, or service this fireplace. Im-
proper use of this fireplace can
cause serious injury or death from
burns, fire, explosions, electrical
shock, and carbon monoxide
poisoning.

 WARNING: Any change to

this fireplace or its controls can
be dangerous.

 WARNINGS

 DANGER: Carbon monoxide

poisoning may lead to death!

This fireplace is a vented product. This
fireplace will not produce any gas leakage
into your home if properly installed. This
fireplace must be properly installed by a
qualified service person. The glass door
must be properly seated and sealed. If this
unit is not properly installed by a qualified
service person with glass door properly
seated and sealed, gas leakage can occur.

Carbon Monoxide Poisoning:

 Early signs

of carbon monoxide poisoning resemble the
flu, with headaches, dizziness, or nausea. If
you have these signs, the fireplace may not
have been installed properly. Get fresh air
at once!
 Have fireplace inspected and ser-
viced by a qualified service person. Some
people are more affected by carbon monox-
ide than others. These include pregnant
women, people with heart or lung disease or
anemia, those under the influence of alcohol,
and those at high altitudes.

Propane/LP gas and natural gas are both
odorless. An odor-making agent is added to
each of these gases. The odor helps you
detect a gas leak. However, the odor added
to these gases can fade. Gas may be present
even though no odor exists.

Make certain you read and understand all
warnings. Keep this manual for reference. It
is your guide to safe and proper operation of
this fireplace.

Содержание EBDV34N

Страница 1: ...anceoradditionalinformation consult a qualified installer ser vice agency or the gas supplier This appliance may be installed in an aftermarket manufactured mobile home where not prohibited by local c...

Страница 2: ...indicated on fire place nameplate 14 This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electri cal Code ANS...

Страница 3: ...c igni tion models require household electricity to operate Figure 1 Vanguard Direct Vent Fireplace EBDV Series Glass Door Assembly Blower Adjustment Optional Installation Valve Burner Pilot Assembly...

Страница 4: ...um 1 clearance to combustibles 34 3 4 37 1 2 41 1 2 34 1 4 34 3 4 36 3 4 20 Vertical Termination 19 Horizontal Termination Note Where three numbers are given the top number is exclusive to the 34 Fire...

Страница 5: ...Vent GS venting components or kits spe cifically approved for this fireplace Important Do not mix Vanguard and Simpson Dura Vent venting Minimum clearance between vent pipes and combustible materials...

Страница 6: ...above paved side walk or a paved driveway located on public property 84 inches 2133mm minimum M clearance under veranda porch deck 12 inches 305mm minimum N clearance above a roof shall extend a minim...

Страница 7: ...ermination Vertical Termination It is important to select the proper length of vent pipe for the type of termination you choose It is also important to note the wall thickness For Horizontal Terminati...

Страница 8: ...combination of pipe and el bows to the appliance adaptor with pipe seams oriented towards the wall or floor Twist lock Procedure The female ends of the pipes and fittings have four locking lugs inden...

Страница 9: ...fire hazard 4 Apply a bead of non hardening mastic around the outside edge of the vent cap Position the vent cap in the center of the 7 1 2 or 10 hole on the exterior wall with the arrow on the vent c...

Страница 10: ...h corner installation UP Flexible Vent Pipe Horizontal Venting See information in Figure 18 for Vertical V and Horizontal H maximums and minimums The same amounts apply for flexible venting Note Figur...

Страница 11: ...8 min 20 max 20 max 8 max 20 max Venting with Two 90 Elbows Vertical V Horizontal H1 Horizontal H2 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max 20 max 20 max Figure 19 Horizontal Termination Con...

Страница 12: ...g members Note Pay spe cial attention to these installation in structions for required clearances air space to combustibles when passing through ceilings walls roofs enclo sures attic rafters etc Do n...

Страница 13: ...ically and horizontally using a level Temporarily tack the support box in place through the inside walls and into the roof sheathing 4 Using tin snips cut the supportbox from the top corners down to t...

Страница 14: ...VENTING INSTALLATION Continued Venting with Two 90 Elbows Vertical V1 Horizontal H 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max Note Vertical V1 Vertical V2 20 max Figure 27 Vertical Rigid Vent...

Страница 15: ...al vanized Pipe 7 12 Firestop Support Roof Flashing RTV Silicone Vertical Termination and 26 screws D1000 7 x 12 Galvanized Coaxial Pipe 6 pcs D1010 7 x 24 Galvanized Coaxial Pipe 6 pcs D1020 7 x 48 G...

Страница 16: ...tem you may run system scirculatingblowerwhile using heater This will help circu late the heat throughout the house In the event of a power outage you can use this heater as your primary heat source W...

Страница 17: ...f exiting through the right side see Figure 33 Route power cord through both plastic bushing s and plug the power cord into a properly grounded 3 prong wall receptacle near the firebox b If your firep...

Страница 18: ...ac ceptable alternative to test gauge connec tion Purchase the CSA design certified equipment shutoff valve from your dealer WARNING A qualified ser vice person must connect fire place to gas supply...

Страница 19: ...of fireplace 3 Attach a 45 flare union gas connector to flexible gas line from gas supply see Figure 36 Connect flare union to flex ible gas line attached to gas regulator of fireplace see Figure 36...

Страница 20: ...hutoff valve see Figure 37 2 Open propane LP supply tank valve for propane LPfireplace or main gas valve located on or near gas meter for natu ral gas fireplace 3 Make sure control knob of fireplace i...

Страница 21: ...s to be connected to the incoming 120 volt regular household wiring that supplies electricity to the fireplace Refer to wiring diagram on page 30 NOTICE The GWMS2 includes 25 of wire for installation...

Страница 22: ...d the side of the firebox see Figure 44 4 Slide the left retainer bracket against the left side brick panel Loosely se cure the bracket screw This secures the left side brick panel 5 Install the right...

Страница 23: ...t modify logs Only use logs supplied with fireplace Removeglassdoor SeeRemoving Replacing GlassDoor page21 Installlogsaccordingto instructions for fireplace model numbers 1 Place log 1 back log on top...

Страница 24: ...five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety in formation in column one If you don t smell gas go to the next step 7 Tu...

Страница 25: ...ill shut off after the firebox temperature decreases The blower helps distribute heated air fromthefireplace Periodicallycheckthe louvers of the firebox and remove any dust dirt or other obstructions...

Страница 26: ...corrosion of caps pipes and fittings and can be caused by having excessive lateral runs too many elbows or exterior portions of the system be ing exposed to cold weather 4 Inspect joints to verify tha...

Страница 27: ...me may be too low causing safety pilot to drop out 2 Vent may be blocked or restricted REMEDY 1 Check to see if you have gas supply and that the equipment shutoff valve is opened 2 Repeat lighting pro...

Страница 28: ...burner until air is removed from line Have gas line checked by local natural gas company 2 Clean burner see Cleaning and Maintenance page 26 or replace burner orifice 1 Adjust the log set so that the...

Страница 29: ...ove 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner flame holes blocked OBSERVED PROBLEM Fireplace produces unwanted odors Fireplace shuts off in use Gas odor even when control k...

Страница 30: ...authorized dealers of this product If they can not supply original replacement part s call DESA International s Technical Service Department at 1 800 DESA LOG 1 800 337 2564 WhencallingDESAInternatio...

Страница 31: ...c Minimum Inlet Supply Pressure 4 5 w c 4 5 w c 4 5 w c Dimension Inches mm HxWxD Fireplace 32 3 16 x 34 3 8 x 18 1 2 33 x 37 x 18 1 2 35 x 41 x 18 1 2 817 x 873 x 470 mm 838 x 940 x 470 mm 838 x 1041...

Страница 32: ...ech com 34 3 1 2 3 23 21 20 22 4 6 19 7 7 8 9 10 11 Included in Hardware Pack 12 13 14 15 16 17 18 25 26 27 28 28 29 31 33 35 36 35 35 37 38 5 5 5 24 48 49 39 44 45 35 46 47 30 43 6 41 40 42 6 32 34 2...

Страница 33: ...7222 01 Transformer 24 VAC 1 21 23416 Mounting Board Electronic 1 22 107221 01 Ignition Module 1 23 14104 Plug 2 Prong 1 24 104514 01 Wall Switch 1 25 104504 01 Burner 1 26 104506 01 Orifice 34 37 1 1...

Страница 34: ...go at the top and bottom of the glass door Note Remove the plasticfilmcoveringonstripsbeforeinstall ing on fireplace BRICK LINER D8037A 34 37 D8041 41 Not Shown This brick liner adds a touch of style...

Страница 35: ...G3003B Series Black Onyx Marble Laminate SLIM HEARTH BASE Not Shown G3005J Series Jade Marble Laminate G3005S Series Sandstone Marble Laminate G3005B Series Black Onyx Marble Laminate The slim hearth...

Страница 36: ...e the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES A...