HIGH ALTITUDE
INSTALLATION

Your Vanguard direct-vent fireplace has
been AGA tested and approved for eleva-
tions from 0-2000 feet and CGA certified
for elevations from 0-4500 feet.

When installing this fireplace at an elevation
above 2000 feet (in the USA), you may need
to decrease the input rating by changing the
existing burner orifice to a smaller size. Re-
duce input 4% for each 1000 feet above sea
level. Check with your  local gas company for
proper orifice size identification.

When installing this fireplace at an eleva-
tion above 4500 feet (in Canada), check
with local authorities.

Consult your local gas company to help de-
termine the proper orifice for your location.

For assistance with any high altitude instal-
lation contact DESA International’s Tech-
nical Service Department at 1-800-DESA-
LOG (1-800-337-2564).

PARTS LISTS FOR VENTING
KITS AND COMPONENTS

Vanguard Rigid Venting

Number Description

BGFVK Basic Ground Floor Rigid Vent Kit

Includes: 7" x 60

°

 Elbow, Extended

Adjustable Horizontal Termination,
Wall Thimble and 14 Screws

GFVK

Ground Floor Rigid Vent Kit

Includes: 7" x 60

°

 Elbow, 7" Adjust-

able Galvanized Coaxial Pipe (7-12"),
Wall Thimble, Horizontal Termina-
tion, RTV Silicone and 16 Screws

BVK

Basement Rigid Vent Kit

Includes: 7" x 30

°

 Elbow, 7" x 4'

Galvanized Pipe, 7" x 90

°

 Elbow, 7"

Adjustable Galvanized Pipe (7-12"),
Wall Thimble, Horizontal Termina-
tion, RTV Silicone and 20 Screws

CVK

Corner Vent Kit

Includes: 7" x 30

°

 Elbow, 7" x 90

°

Elbow, 7" Adjustable Galvanized
Pipe (7-12"), 6" Pipe, Wall Thimble,
Horizontal Termination, RTV Sili-
cone and 20 Screws

Number Description

SVK

Snorkel Rigid Vent Kit

Includes: 7" x 30

°

 Elbow, 7" x 4'

Galvanized Pipe, 7" x 90

°

 El-

bow, 7" Adjustable Galvanized
Pipe (7-12"), Wall Thimble, 36"
Snorkel Termination, RTV Sili-
cone and 28 Screws

RVF

Roof Rigid Vent Kit

Includes: Flue Restrictor, Storm
Collar, 7" x 30

°

 Elbow, 7" x 4'

Galvanized Pipe, 7" x 2' Galva-
nized Pipe, 7" Adjustable Gal-
vanized Pipe (7-12"), Firestop
Support, Roof Flashing, RTV
Silicone, Vertical Termination,
and 26 screws

D1000

7" x 12" Galvanized Coaxial
Pipe(6 pcs.)

D1010

7" x 24" Galvanized Coaxial
Pipe(6 pcs.)

D1020

7" x 48" Galvanized Coaxial
Pipe(6 pcs.)

D1030

7" Adjustable (7-12")
Galvanized Coaxial Pipe
(6 pcs.)

D1050

7" x 6" Galvanized Coaxial Pipe
(6 pcs.)

D2000

7" x 90

°

 Elbow (6 pcs.)

D2010

7" x 45

°

 Elbow (6 pcs.)

D2020

7" x 30

°

 Elbow (6 pcs.)

D2030

7" x 60

°

 Elbow (6 pcs.)

D3000

Wall Strap/Offset Support (6 pcs.)

D3010

Storm Collar (6 pcs.)

D3020

Wall Thimble (6 pcs.)

D3050

Vertical Restrictor (6 pcs.)

D3060

Ceiling Firestop/Support (6 pcs.)

D3070

Rectangular Horizontal Rigid
Vent Termination Cap

D3071

Adjustable Horizontal Rigid
Vent Termination Cap

D3090

Cathedral Ceiling Support Box

D4000

Roof Flashing 6/12-9/12

D4010

Roof Flashing 9/12-12/12

D4020

Flex Connector (6 pcs.)

D4030

Flex Wall Thimble (6 pcs.)

D4040

4" Hose Clamp (6 pcs.)

D4050

7" Hose Clamp (6 pcs.)

D5000

Wood/Vinyl Siding Standoff
(6 pcs.)

SIMPSON DURA-VENT GS
4" x 6 

5

/

"

Number Description

Available from DESA International:

SD2040

Simpson Dura-Vent GS
30

°

 Elbow (6 pcs.)

SD2050

Simpson Dura-Vent GS
60

°

 Elbow (6 pcs.)

Available from Simpson Dura-Vent
Only:

902

7" x 48" Pipe

903

7" x 36" Pipe

904

7" x 24" Pipe

906

7" x 12" Pipe

907

7" x 9" Pipe

908

7" x 6" Pipe

911

7" Adjustable (11"-14 

5

/

8

") Pipe

940

Wall Thimble

941

Cathedral Ceiling Support Box

943

Roof Flashing 0/12-6/12

943S Roof Flashing 7/12-12/12
945

7" x 45

°

 Elbow

950

Vinyl Siding Standoff

953

Storm Collar

963

Ceiling Firestop

981

36" Snorkel Termination

984

Horizontal Termination Vent Cap

988

Wall Strap

990

7" x 90

°

 Elbow

991

Vertical High Wind Termination

Vanguard Flexible Venting

Number Description

BFGFVK Basic Flex Ground Floor Vent Kit

Includes: Flex Adapter, 7" x 2'
Flexible Pipe, 4" x 2' Flexible
Pipe, Wall Thimble, Horizontal
Termination, (2) Spacer Springs,
(2) 4" Hose Clamps, (2) 7" Hose
Clamps, and 10 Screws

FGFVK

Flex Ground Floor Vent Kit

Includes: Flex Adapter, 7" x 4'
Flexible Pipe, 4" x 4' Flexible Pipe,
Wall Thimble, Horizontal Termi-
nation, (4) Spacer Springs, (2) 4"
Hose Clamps, (2) 7" Hose Clamps,
RTV Silicone, and 10 Screws

D1040

7" x 25' Coaxial Flex Pipe
with Spacer Springs

D3080

Rectangular Horizontal Flex
Termination Cap

Vanguard Rigid Venting 

(Cont.)

Содержание EBDV34N

Страница 1: ...anceoradditionalinformation consult a qualified installer ser vice agency or the gas supplier This appliance may be installed in an aftermarket manufactured mobile home where not prohibited by local c...

Страница 2: ...indicated on fire place nameplate 14 This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electri cal Code ANS...

Страница 3: ...c igni tion models require household electricity to operate Figure 1 Vanguard Direct Vent Fireplace EBDV Series Glass Door Assembly Blower Adjustment Optional Installation Valve Burner Pilot Assembly...

Страница 4: ...um 1 clearance to combustibles 34 3 4 37 1 2 41 1 2 34 1 4 34 3 4 36 3 4 20 Vertical Termination 19 Horizontal Termination Note Where three numbers are given the top number is exclusive to the 34 Fire...

Страница 5: ...Vent GS venting components or kits spe cifically approved for this fireplace Important Do not mix Vanguard and Simpson Dura Vent venting Minimum clearance between vent pipes and combustible materials...

Страница 6: ...above paved side walk or a paved driveway located on public property 84 inches 2133mm minimum M clearance under veranda porch deck 12 inches 305mm minimum N clearance above a roof shall extend a minim...

Страница 7: ...ermination Vertical Termination It is important to select the proper length of vent pipe for the type of termination you choose It is also important to note the wall thickness For Horizontal Terminati...

Страница 8: ...combination of pipe and el bows to the appliance adaptor with pipe seams oriented towards the wall or floor Twist lock Procedure The female ends of the pipes and fittings have four locking lugs inden...

Страница 9: ...fire hazard 4 Apply a bead of non hardening mastic around the outside edge of the vent cap Position the vent cap in the center of the 7 1 2 or 10 hole on the exterior wall with the arrow on the vent c...

Страница 10: ...h corner installation UP Flexible Vent Pipe Horizontal Venting See information in Figure 18 for Vertical V and Horizontal H maximums and minimums The same amounts apply for flexible venting Note Figur...

Страница 11: ...8 min 20 max 20 max 8 max 20 max Venting with Two 90 Elbows Vertical V Horizontal H1 Horizontal H2 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max 20 max 20 max Figure 19 Horizontal Termination Con...

Страница 12: ...g members Note Pay spe cial attention to these installation in structions for required clearances air space to combustibles when passing through ceilings walls roofs enclo sures attic rafters etc Do n...

Страница 13: ...ically and horizontally using a level Temporarily tack the support box in place through the inside walls and into the roof sheathing 4 Using tin snips cut the supportbox from the top corners down to t...

Страница 14: ...VENTING INSTALLATION Continued Venting with Two 90 Elbows Vertical V1 Horizontal H 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max Note Vertical V1 Vertical V2 20 max Figure 27 Vertical Rigid Vent...

Страница 15: ...al vanized Pipe 7 12 Firestop Support Roof Flashing RTV Silicone Vertical Termination and 26 screws D1000 7 x 12 Galvanized Coaxial Pipe 6 pcs D1010 7 x 24 Galvanized Coaxial Pipe 6 pcs D1020 7 x 48 G...

Страница 16: ...tem you may run system scirculatingblowerwhile using heater This will help circu late the heat throughout the house In the event of a power outage you can use this heater as your primary heat source W...

Страница 17: ...f exiting through the right side see Figure 33 Route power cord through both plastic bushing s and plug the power cord into a properly grounded 3 prong wall receptacle near the firebox b If your firep...

Страница 18: ...ac ceptable alternative to test gauge connec tion Purchase the CSA design certified equipment shutoff valve from your dealer WARNING A qualified ser vice person must connect fire place to gas supply...

Страница 19: ...of fireplace 3 Attach a 45 flare union gas connector to flexible gas line from gas supply see Figure 36 Connect flare union to flex ible gas line attached to gas regulator of fireplace see Figure 36...

Страница 20: ...hutoff valve see Figure 37 2 Open propane LP supply tank valve for propane LPfireplace or main gas valve located on or near gas meter for natu ral gas fireplace 3 Make sure control knob of fireplace i...

Страница 21: ...s to be connected to the incoming 120 volt regular household wiring that supplies electricity to the fireplace Refer to wiring diagram on page 30 NOTICE The GWMS2 includes 25 of wire for installation...

Страница 22: ...d the side of the firebox see Figure 44 4 Slide the left retainer bracket against the left side brick panel Loosely se cure the bracket screw This secures the left side brick panel 5 Install the right...

Страница 23: ...t modify logs Only use logs supplied with fireplace Removeglassdoor SeeRemoving Replacing GlassDoor page21 Installlogsaccordingto instructions for fireplace model numbers 1 Place log 1 back log on top...

Страница 24: ...five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety in formation in column one If you don t smell gas go to the next step 7 Tu...

Страница 25: ...ill shut off after the firebox temperature decreases The blower helps distribute heated air fromthefireplace Periodicallycheckthe louvers of the firebox and remove any dust dirt or other obstructions...

Страница 26: ...corrosion of caps pipes and fittings and can be caused by having excessive lateral runs too many elbows or exterior portions of the system be ing exposed to cold weather 4 Inspect joints to verify tha...

Страница 27: ...me may be too low causing safety pilot to drop out 2 Vent may be blocked or restricted REMEDY 1 Check to see if you have gas supply and that the equipment shutoff valve is opened 2 Repeat lighting pro...

Страница 28: ...burner until air is removed from line Have gas line checked by local natural gas company 2 Clean burner see Cleaning and Maintenance page 26 or replace burner orifice 1 Adjust the log set so that the...

Страница 29: ...ove 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner flame holes blocked OBSERVED PROBLEM Fireplace produces unwanted odors Fireplace shuts off in use Gas odor even when control k...

Страница 30: ...authorized dealers of this product If they can not supply original replacement part s call DESA International s Technical Service Department at 1 800 DESA LOG 1 800 337 2564 WhencallingDESAInternatio...

Страница 31: ...c Minimum Inlet Supply Pressure 4 5 w c 4 5 w c 4 5 w c Dimension Inches mm HxWxD Fireplace 32 3 16 x 34 3 8 x 18 1 2 33 x 37 x 18 1 2 35 x 41 x 18 1 2 817 x 873 x 470 mm 838 x 940 x 470 mm 838 x 1041...

Страница 32: ...ech com 34 3 1 2 3 23 21 20 22 4 6 19 7 7 8 9 10 11 Included in Hardware Pack 12 13 14 15 16 17 18 25 26 27 28 28 29 31 33 35 36 35 35 37 38 5 5 5 24 48 49 39 44 45 35 46 47 30 43 6 41 40 42 6 32 34 2...

Страница 33: ...7222 01 Transformer 24 VAC 1 21 23416 Mounting Board Electronic 1 22 107221 01 Ignition Module 1 23 14104 Plug 2 Prong 1 24 104514 01 Wall Switch 1 25 104504 01 Burner 1 26 104506 01 Orifice 34 37 1 1...

Страница 34: ...go at the top and bottom of the glass door Note Remove the plasticfilmcoveringonstripsbeforeinstall ing on fireplace BRICK LINER D8037A 34 37 D8041 41 Not Shown This brick liner adds a touch of style...

Страница 35: ...G3003B Series Black Onyx Marble Laminate SLIM HEARTH BASE Not Shown G3005J Series Jade Marble Laminate G3005S Series Sandstone Marble Laminate G3005B Series Black Onyx Marble Laminate The slim hearth...

Страница 36: ...e the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES A...

Отзывы: