VBT-75P S2 USER’S MANUAL REV 1.0
14
3.6
Performing a Test
Follow the steps below to perform a test:
a.
Start from the “START-UP” menu:
Press the
[1]
key (
RUN TEST
).
b.
The following screen will be displayed:
Select the test time by pressing the corresponding number on the keypad. For this
example, we will use the 5 second test time by pressing the
[1]
key.
c.
The following screen will be displayed:
Type the desired test voltage using the numeric keypad and then press the
[ENTER]
key.
d.
The following screen will be displayed:
Select the leakage current limit by pressing the corresponding number on the keypad.
For this example, we will select 300
μ
A by pressing the
[1]
key.
e.
The following screen will be displayed summarizing the test parameters:
Press the
[ENTER]
key to confirm the test parameters.
TEST PARAMETERS:
75KV 5Sec 300
μ
A
"CLEAR TO CHANGE OR
"ENTER" TO CONTINUE
1. 300
μ
A
2. 200
μ
A
3. 100
μ
A
ENTER TEST VOLTAGE:
(10 to 75)
0 KV
1. 5 Sec 2. 10 Sec
3. 30 Sec 4. 60 Sec
5. 2 Min
1.RUN TEST 07/10/17
2.SETUP 13:37:29
3.RECORDS
CABLE VTG: 0V