background image

CT-7500 S2 USER’S MANUAL

REV 2

 

 

 

1

 

Calibrating the Resistor Transducer Adapter 

The Vanguard Resistor Transducer Adapter must be calibrated each time a different resistor 
transducer is connected to the adapter. Follow the steps below to calibrate the adapter: 

a.

 

Connect the resistor transducer to the adapter. 

b.

 

Turn on the circuit breaker timer. The following “RUNNING” screen will be displayed on 
the resistor transducer adapter’s LCD screen: 

 

Press either the 

[

]

 or 

[

]

 key to access the Main Menu. 

c.

 

The Main Menu will be displayed: 

 

Press the 

[

key to select the 

CALIBRATE ENCODER

 option: 

 

Press the 

[ENTER]

 key. 

d.

 

The following screen will be displayed: 

 

Move the resistor transducer to one end of its travel and then press the 

[ENTER]

 key. 

e.

 

The following screen will be displayed: 

 

Move the resistor transducer to the opposite end of its travel and then press the 

[ENTER]

 key. 

    SET ENCODER TO

    POSITION 2 

 

“ENTER” WHEN DONE 

    SET ENCODER TO

    POSITION 1 

 

“ENTER” WHEN DONE 

<CALIBRATE ENCODER>

ADJUST CONTRAST 

DIAGNOSTIC 

 

CALIBRATE ENCODER

ADJUST CONTRAST 

<DIAGNOSTIC> 

 

RUNNING 

 

 

Res Enc Rev: 1.00 

Содержание CT-7500 S2

Страница 1: ...RESISTOR TRANSDUCER ADAPTER USER S GUIDE Vanguard Instruments Company Inc 1520 S Hellman Ave Ontario California 91761 USA TEL 909 923 9390 FAX 909 923 9391 March 2011 Revision 1 ...

Страница 2: ...s LCD screen Press either the or key to access the Main Menu c The Main Menu will be displayed Press the key to select the CALIBRATE ENCODER option Press the ENTER key d The following screen will be displayed Move the resistor transducer to one end of its travel and then press the ENTER key e The following screen will be displayed Move the resistor transducer to the opposite end of its travel and ...

Страница 3: ... value to the known traveled distance distance between the endpoints of the transducer and then press the ENTER key The following screen will be displayed momentarily The following screen will then be displayed RUNNING Res Enc Rev 1 00 CALIBRATION SAVED TO SET DISTANCE 5 00 IN 12 70 CM ENTER WHEN DONE ...

Страница 4: ...ing screen will be displayed Press the key to select the ADJUST CONTRAST option Press the ENTER key b The following screen will be displayed Press the or key to adjust the screen contrast to the desired level and then press the ENTER key The RUNNING screen will be displayed again ADJUST CONTRAST TO ADJUST ENTER WHEN DONE CALIBRATE ENCODER ADJUST CONTRAST DIAGNOSTIC CALIBRATE ENCODER ADJUST CONTRAS...

Страница 5: ... highlighted Press the ENTER key c The following screen will be displayed Move the resistor transducer and observe the distance values on the screen Move the resistor transducer to the other end of its travel and observe the screen The value should be the distance between the two endpoints of the transducer If this value is not correct you should calibrate the adapter ENCODER TRAVEL 5 00 IN 12 7 C...

Страница 6: ...CT 7500 S2 USER S MANUAL REV 2 5 Connection Illustrations Figure 1 Typical Connection to ABB AHMB Transducer Figure 2 Typical Connection to a Resistor Transducer ...

Страница 7: ...ve Ontario CA 91761 USA Phone 909 923 9390 Fax 909 923 9391 www vanguard instruments com Copyright 2011 by Vanguard Instruments Company Inc Resistor Transducer Adapter Calibration Procedure Revision 1 0 March 1 2011 TA ...

Отзывы: