VG-PB200W-C  200W  Bicolor  LED  Fresnel  Spot  light  User  Manual                                                VG-PB200W-C  200W  Bicolor  LED  Fresnel  Spot  light  User  Manual 

intelligent temperature control system, improve the quality of our products stable 

performance, apply to indoor installation. 

Using brand LED chips, integrated encapsulation, improve reliability and long lifespan. 

Using the advanced optical reflective material, make the light on the projection distance 

and brightness is higher than traditional film soft light. 

 

 OVERVIEW AND DIMENSIONS                                                                                                                   

 

   

 

All dimensions are in millimeters 

 

 SAFETY INFORMATION                                                                                                                 

Important 

Every person involved with the installation, operation and maintenance of this device has to 

be qualified and follow the instructions of this manual. Manufacturer will not with 

responsibility for those operations which are not according to this Instruction.   

Verify that the voltage matches the rated voltage. 

When the voltage is 110V, Do not connect more than 10 lightings in total to AC mains 

power in one interconnected daisy chain   

When the voltage is 220V, Do not connect more than 20 lightings in total to AC mains 

power in one interconnected daisy chain   

Before using the fixture, check that all power distribution equipment and cables are in 

perfect condition and rated for the current requirements of all connected devices. 

Always ground (earth) the fixture electrically. 

Avoiding hit the Light when you are move or install the light. 

The minimum distance between light-output and the illuminated surface must be more 

than 0.5 meters. Keep all combustible materials (for example fabric, wood, paper) at least 

0.2 meters away from the fixture. 

Do not expose the fixture to rain or moisture. 

Avoid looking directly into the light source (especially those who suffer from epileptic fits) 

Maximum ambient temperature (Ta) is 40°C. Do not operate fixture at temperatures higher 

than this.   

The Maximum surface temperature is 50°C 

When suspending the fixture above ground level, verify that the structure can hold at least 

10 times the weight of all installed devices. 

Verify that all external covers and rigging hardware are securely fastened and use an 

approved means of secondary attachment such as a safety cable.   

 

 POWER CONNECTION                                                                                                               

03 

02 

Содержание VG-PB200W-C

Страница 1: ...ht User Manual VG PB200W C 200W Bicolor LED Fresnel Spot light User Manual 200W Bicolor LED Fresnel Spot Light VG PB200W C CE RoHS User Manual Please read this user manual before using this product Keep it for further reference http www vangaa com ...

Страница 2: ...ss COB LED chips beads matrix arrangement of large area through the whole aluminum shell to realize heat dissipation naturally we have designed this light This light has high brightness good head dissipation ultra quiet and other features It can satisfy the requirement of indoor movie filming for the lighting layout It is a good substitute of the traditional Fresnel spot light which is very suitab...

Страница 3: ...chain When the voltage is 220V Do not connect more than 20 lightings in total to AC mains power in one interconnected daisy chain Before using the fixture check that all power distribution equipment and cables are in perfect condition and rated for the current requirements of all connected devices Always ground earth the fixture electrically Avoiding hit the Light when you are move or install the ...

Страница 4: ...ed electrician RELAYING POWER TO OTHER DEVICES The lightings can be linked in a chain by power cables which installed a blue and a light gray connectors on the two ends The light gray connector connects to the power out socket of the first lighting and the blue connector connects to the power in socket of the subsequent lighting and so on The power cable must is a three conductor 2 5mm2 cable When...

Страница 5: ...ape the current menu and save the selected item or parameter MAIN MENU The way into the menu as below 1 Press ENTER when the display show the title information 2 Press UP or DOWN button to choose the right menu which you need 3 Press ENTER into the menu 4 Press UP and DOWN button to set the parameter or setting 5 Press ENTER to save the setting 6 Press MENU SET button to back MENU MAP LCD SHOW Fun...

Страница 6: ...mation 2 Press UP DOWN to choose the Mode menu then press ENTER into 3 Press UP DOWN to choose Alone scene menu then press to save 4 Press UP DOWN to choose Set auto mode Color Temperature menu then press ENTER into the option of color temperature 5 Press UP DOWN to choose Set auto mode Dimmer menu then press ENTER into the adjust function of the LED 6 Press UP DOWN to adjust the brightness 000 li...

Страница 7: ...nly for indoor use when you install it by hanging please use the safety cable to ensure the safety If you have any questions please contact with our sales manager Ⅷ TECHNICAL SPECIFICATION Input power AC100 240V 50 60Hz Power consumption 250W Light sources 200W brand bicolor COB LED Lamps LED lifespan 50 000hours Dimmer 0 100 0 15 smoothly dimmer Beam angle 15 60degree Color rendering index 92Ra C...

Страница 8: ...t light User Manual Unqualified person involved with installation operation and maintenance of this device is prohibited If any above mentioned problem happened or unknown problem happened please contact manufacturer or distributor for assistance Innovation Quality Performance Achieving Users Value 12 ...

Отзывы: