OPERATION

 

 
POWERING UP THE

 

SpinVessel® SYSTEM 

 

The  Power  Switch  (I/O)  is  located  on  the  back  of  the  Controller.  To  power  up  the  Controller, 
depress 

the “I” of the switch.  

 

 
OPERATING THE

 

SpinVessel® With COMPUTER CONTROL 

 

The SpinVessel

® Models with “

-

CC” in the part number are controlled using a computer.  The 

Controller for the computer controllable SpinVessel® is connected by a USB communication 
cable to a computer. The Controller accepts simple ASCII commands to set the speed of the 
rotations, the number of rotations (including fractions of a rotation), duration of pause before 
reversing direction and degree of ramping to speed set. 
 

Software details 

1.

 

The SpinVessel® Controller uses an internal CH340G USB to Serial Converter (set to 

9600,8,N,1) which will require driver software.  Windows may already have the needed 

USB driver software installed.  If not, download 

the “CH340 USB DRIVER” 

from the 

provided USB flash drive 

and run “CH341SER.exe” to install it (Windows typically auto

-

installs once downloaded).  If your company policy does not allow the use of the 

provided USB stick, this driver is also available for download from the internet (contact 

your IT department for assistance if necessary). 

2.

 

The basic command language for this computer-to-stirrer communication is ASCII. 

3.

 

Commands can be sent from the computer using a standard terminal program like 

HyperTerminal or Realterm.  Or, if needed, download the V&P Scientific Serial Terminal 

program from the provided USB flash drive.  If your company policy does not allow the 

use of the provided USB stick, we suggest asking your IT department for a 

recommendation. 

4.

 

Alternatively, the ASCII commands can be sent by an automated liquid handler’s software 

to control the SpinVessel®.  Since there are many different automated liquid handlers 

available, please contact a technical representative from the company that makes the 

liquid handler. 

Содержание SpinVessel 650ml

Страница 1: ...IONS FOR 650ml SpinVessel with VP 418SV2E 650 CC US and Foreign Patents Pending SpinVessel System with Computer Control feature for 650ml SpinVessel Tube VP 418SVE 650 CC includes Motor Unit Spin Base Controller and Power Supply Shown with SpinVessel VP 830SV 650FB sold separately ...

Страница 2: ...4 Connect Power Cable from Power Supply to Controller Warning Do not plug Controller in while power is on Ensure that the Power Switch is in the off position 0 is down Always have Controller plugged in before powering up 5 Connect Controller Cable from the Motor Unit to the Controller 6 Connect the USB Cable from the Controller to the computer Power Switch Power Cord Receptacle USB Cable Connector...

Страница 3: ...em Is Composed of Lid Support and Lid Support Plate Controller Cable USB Cable Motor Unit with Spin Base Lid and Lid Support System Controller Power Cord Power Cable Power Supply Controller Cable Spin Base Lid Support Lid Lid Support Plate Motor Unit ...

Страница 4: ...e motor unit is SLAS format 127 7mm x 85 5mm which will fit into any SLAS plate locator or carrier To align pipet tips to inside of SpinVessel tube use the registration disc Place disc on top of the drive base not the tube Lower the pipet tips until they just touch the disc Align robot tips to the holes This registers the pipet head to the SpinVessel and prevents the pipet tips from hitting the Sp...

Страница 5: ...er software installed If not download the CH340 USB DRIVER from the provided USB flash drive and run CH341SER exe to install it Windows typically auto installs once downloaded If your company policy does not allow the use of the provided USB stick this driver is also available for download from the internet contact your IT department for assistance if necessary 2 The basic command language for thi...

Страница 6: ...5 Create ASCII command strings as outlined in the diagram shown below to control the instrument with the following parameters a Speed of rotation in revolutions per minute RPM b Number of rotations before reversing direction c Fraction of a rotation input 0 9 for fractions of a rotation d Pause in milliseconds before reversing direction e Ramping 0 100 where 0 is no ramping rapid acceleration and ...

Страница 7: ...s phenomenon The following settings are ones to use when first testing the VP 418SV 650FB CC SpinVessel Speed 150 RPM Rotate 2 1 Pause 200 milliseconds Ramp 10 It is always a good idea to practice with water in the SpinVessel to determine safe RPM rotation pause and ramp numbers before using expensive reagents Note that if Ramp is set to 0 liquid will splash out of the 650 ML Spin Vessel The VP 41...

Страница 8: ...f hazard can be greatly reduced by proper design selection installation and use but all hazards cannot be completely eliminated The following safety precautions must be observed during all phases of installation operation service and repair of this motor control product Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design m...

Страница 9: ...replace the product Damage to the product caused by user negligence is not covered Please keep the special shipping carton in case the unit needs to be shipped back to V P Scientific Please contact V P Scientific at the address below for return authorization and shipping instructions This warranty is made in lieu of other warranties expressed or implied including the warranties of merchantability ...

Отзывы: