17
Engineer programming via the browser
Configuration
256
Vanderbilt
Installation & Configuration Manual
A6V10276959
01.05.2016
area outputs are “External Bell”, “Alarm”, etc.
Wireless FOB – this condition can be configured for a particular user or for any
user. With this configuration, if the configured user (or any user) presses the ‘*’
key on the FOB, it will cause an instantaneous pulse OFF/ON/OFF. This only
applies for FOBs that have been registered with the system.
Wireless FOB Panic - – this condition can be configured for a particular user or
for any user. With this configuration, if the configured user (or any user)
presses the ‘*’ key on the FOB Panic, it will cause an instantaneous pulse
OFF/ON/OFF. This only applies for FOB Panics that have been registered with
the system.
WPA – the trigger is activated if a button or combination of buttons is pressed.
It is possible to assign a trigger condition to all WPAs or just to one specific
WPA. When a trigger with a WPA trigger condition is defined, it can be
assigned to a mapping gate for many purposes including arming a system,
turning on lights or opening a door.
Keypad valid PIN – this condition can be configured for a particular user or for
any user. With this configuration, if the configured user (or any user) enters a
valid PIN, or presents a configured PACE, it will cause an instantaneous pulse
OFF/ON/OFF.
Keyswitch – the trigger can be configured for a specific key position on the
keyswitch.
Time Trigger –the trigger is on at the specific time entered in the box provided,
in the format hh:mm.
WARNING
Your system will not comply with EN standards if you enable a trigger to set the
system without a valid PIN being required.
17.9.8.2
Mapping Gates
Triggers are used with Mapping Gates, which are virtual outputs defined by the
user that can be mapped to a physical output. There can be a maximum of 512
Mapping Gates.
For continuous output, when the trigger is a valid user code, both states must be
the same, either both negative or both positive.
1. Select Configuration > Advanced > Mapping Gates.
The following window will be displayed.
2. Enter a Description for the gate. This is important as no mapping gate number,
only the description, is displayed on the Outputs user page for turning on and
off gates.
Содержание SPCK620
Страница 1: ...A6V10276959 Vanderbilt 01 05 2016 SPC42xx 43xx 52xx 53xx 63xx Installation Configuration Manual 3 6 ...
Страница 364: ...23 Appendix ATP Category Timings 364 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 365: ...Appendix 23 ATP Category Timings 365 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 366: ...23 Appendix ATP Category Timings 366 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 367: ...Appendix 23 ATP Category Timings 367 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...