background image

 

 

5502 Timberlea Blvd,   Mississauga,  ON   L4W 2T7        Tel: (905) 366-3377    Fax: (905) 366-3378 

CM-500 SK 

500 USER CODES 

KEYPAD

 

Request-to-exit PB1 

Request-to-exit PB2 

Common PB1 PB2 

N/O contact relay 1 

Common relays 

N/O contact relay 2 

V1 

Varistor 

ST1  Jumper for the reset 
ST2  Jumper for relay 1 

RL1  Door relay 1

 

RL2  Door relay 2

 

 

12  Input voltage 

Input voltage 

Data 

M  Common M

 

 

This device comes with a varistor, which must be connected to the strike 
terminal (or electromagnet) operated by the device.  
If this product is connected to more than one strike, each of them should 
have a varistor.  The varistor controls the overload produced by the strike 
coil  – back emf. 

If you are using a « Shear Lock » electromagnetic lock, it is recommended to use a separate power 
supply than the one connected to the CM-500SK

3

 

2

 

V

 

1

 

E

 

M

 

B

 

O

 

C

 

T

 

5

 

12

 

RL1

 

RL2

 

3

 

2

 

1

 

ST1

 

ST2

 

1

 

3

 

PB1 

V1

 

Input voltage

 

12V AC/DC

 

Strike

 

ST2

 

1

 

3

 

1

 

3

 

 

N/C contact RL1 (magnet)

 

PB2 

 

Auxiliary keypad (see wiring) 

Wiring diagram

 

PCB front view 

N/O contact RL1 (strike)

 

Содержание CM-500SK

Страница 1: ...ch must be connected to the strike terminal or electromagnet operated by the device If this product is connected to more than one strike each of them should have a varistor The varistor controls the o...

Страница 2: ...pad 1 beep long Validating data in programming mode master code user code or time outputs Or user access code valid 2 beeps short Entry in programming mode Or exit from programming mode 4 beeps short...

Страница 3: ...he master code twice for the first use the master code default value is 12345 The orange LED and two beeps sound to confirm entry in the programming mode Key in keypad time Enter 0 then the time in se...

Страница 4: ...eing in one of the user number and the LED is green a data computing error signal sounds Enter a new user number Deleting or replacing programmed codes 1 Enter the master code twice for the first use...

Страница 5: ...pply White User codes list make photocopy if needed 1 2 3 4 5 6 7 8 9 0 3 2 V 1 E M B O C T 5 12 RL1 RL2 1 ST1 ST2 1 2 3 Input Voltage 12V AC DC Grey Yellow Brown White Operating the auxiliary reader...

Страница 6: ...ammed values Key in keypad time 0 10 10 sec 99 99 sec Door release time relay 1 RL1 1 01 1 sec 99 99 sec Door release time relay 2 RL2 2 01 1 sec 99 99 sec Master Code 3 5 digit Programmed by Date Bui...

Страница 7: ...Page 7 of 7 CM 500SK Template 20 5 mm 105 mm 120 mm 135 mm 23 mm 43 mm 15 mm 38 mm 61 mm 75 5 mm Wiring access area 30 mm x 40 mm...

Отзывы: