Setting user codes 

The user codes are programmed from the main unit (CM-500SK). The key # cannot be used in a code. To validate a user 
code faster, it is recommended to enter the user code starting by the first user number of each group. 

1.

 

Enter the master code twice (for the first use the master code default value is 12345). 
        The orange LED and two beeps sound to confirm entry in programming mode. 

2.

 

Enter a user number (000 to 249) for door 1 and user number (250 to 499) for door 2. 
        The LED lights off for 1 second and one beep sounds. 

3.

 

If the LED is green, enter the 5-digit code the LED lights off for 1 second and one beep sounds.  
        The orange LED confirms that the code is accepted. 

Or, 

To skip the user number press #. The LED turns to orange and one beep sounds. 

4.

 

If the LED is red (the user number is taken), to delete the programmed code press * (star) twice, the LED turns green 
 or else enter another user number. 

5.

 

To exit from the programming mode, press #. 2 beeps sound to confirm that you left the programming mode. 

 

When the LED is green, press the # key to a) leave a user number empty and then enter another user number or, 
b) to continue programming. If the # key is not pressed while being in one of the user number and the LED is green, a data 
computing error signal sounds. Enter a new user number. 

 
 

Deleting or replacing programmed codes  

 

1.

 

Enter the master code twice (for the first use the master code default value is 12345).    
        The orange LED and 2 beeps sound to confirm entry in programming mode. 

2.

 

Enter the user number to delete (000 to 499). The LED turns off for 1 second and one beep sounds. 

3.

 

The LED turns red indicating that the current user number is not available. 

4.

 

Press 

. The LED turns green to confirm that the user number is now available. 

5.

 

Enter the new 5-digit user code. 

Or, 

6.  Press the # key to continue. 

7.

 

Enter a new user number to program another user code. 

Or,

 

8.

 

To exit from programming mode, press #. 2 beeps confirm that the device is back to normal mode 
(standby). 

 
 

Reset of the master code and of the user codes 

 

1.

 

Place the jumper ST1 in 2-+3 position. 

2.

 

The green LED flashes during 5 seconds. The master code 12345 is set back as the default code. 

3.

 

One beep sounds. The LED turns to red and flashes. 

4.

 

Remove the jumper from the 2 + 3 position to go back to standby mode. 

Or,

 

5.

 

Keep the jumper in place 2 + 3 position to reset all the user codes. 

6.

 

The red LED flashes during 5 seconds and then stops during the deletion of the user codes. 

7.

 

Once all the user codes are deleted, the LED turns off. 

8.

 

Remove the jumper from the 2 + 3 position to go back to standby mode. 

 

Содержание CM-500SK

Страница 1: ...ch must be connected to the strike terminal or electromagnet operated by the device If this product is connected to more than one strike each of them should have a varistor The varistor controls the o...

Страница 2: ...pad 1 beep long Validating data in programming mode master code user code or time outputs Or user access code valid 2 beeps short Entry in programming mode Or exit from programming mode 4 beeps short...

Страница 3: ...he master code twice for the first use the master code default value is 12345 The orange LED and two beeps sound to confirm entry in the programming mode Key in keypad time Enter 0 then the time in se...

Страница 4: ...eing in one of the user number and the LED is green a data computing error signal sounds Enter a new user number Deleting or replacing programmed codes 1 Enter the master code twice for the first use...

Страница 5: ...pply White User codes list make photocopy if needed 1 2 3 4 5 6 7 8 9 0 3 2 V 1 E M B O C T 5 12 RL1 RL2 1 ST1 ST2 1 2 3 Input Voltage 12V AC DC Grey Yellow Brown White Operating the auxiliary reader...

Страница 6: ...ammed values Key in keypad time 0 10 10 sec 99 99 sec Door release time relay 1 RL1 1 01 1 sec 99 99 sec Door release time relay 2 RL2 2 01 1 sec 99 99 sec Master Code 3 5 digit Programmed by Date Bui...

Страница 7: ...Page 7 of 7 CM 500SK Template 20 5 mm 105 mm 120 mm 135 mm 23 mm 43 mm 15 mm 38 mm 61 mm 75 5 mm Wiring access area 30 mm x 40 mm...

Отзывы: