![CAMDEN CM-500SK Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/camden/cm-500sk/cm-500sk_instructions-manual_3626333002.webp)
Page 2 of 7
Technical specifications
Input voltage
12 VAC/DC
Outputs
2 relay outputs, contact N/O & N/C 3 amp@125V
User codes
500 user codes
Master code
5-digit programmable master code
Inputs
2 request to exit inputs
Keypad
12-digit keypad with built-in buzzer
Distance between
CM-500SK and auxiliary keypad
Maximum 50 meter
(recommended cable 4 x 0.6 mm
2
)
Default values
Master code:
12345
Time outputs:
1 second
Key-in keypad time:
10 seconds
Audible signals
1 beep (short) Pressing any key on the keypad
1 beep (long) Validating data in programming mode: master code, user code
or time outputs.
Or user access code valid
2 beeps (short) Entry in programming mode
Or exit from programming mode
4 beeps (short) Incorrect user number keyed in
Or non valid user code or non valid time outputs
Visual signals
LED colour
Normal mode
Programming mode
LED off
Standby
Green
Door relay activated
User number available
Red
User number taken
Orange
In programming mode
Orange flashing
Standby
Data computing error
Request to exit
THE REQUEST-TO-EXIT BUTTON ACTIVATES RELAY
1 AND RELAY 2 (THE OUTPUT, MOMENTARY OR
LATCHED,
AND THE TIME OUTPUTS ARE PROGRAMMABLE).
THE GREEN LED LIGHTS ON WHEN THE DOOR
RELAY IS ACTIVATED.