www.vanco1.com
800-626-6445
10
SAFETY AND NOTICE
The HDWIRKIT/HDWIR-RX has been tested for conformance to safety regulations and requirements, and has
been certified for international use. However, like all electronic equipment, the HDWIRKIT/HDWIR-RX should
be used with care. Please read and follow the safety instructions to protect yourself from possible injury and
to minimize the risk of damage to the unit.
• Follow all instructions and warnings marked on this unit.
• Do not attempt to service this unit yourself, except where explained in this manual.
• Provide proper ventilation and air circulation and do not use near water.
• Keep objects that might damage the device and assure that the placement of this unit is on a stable surface.
• Use only the power adapter and power cords and connection cables designed for this unit.
• Do not use liquid or aerosol cleaners to clean this unit.
• Always unplug the power to the device before cleaning.
TROUBLE-SHOOTING
1. If the display has “waiting for connection” on the bottom right hand corner:
Check to see if the power supply of the transmitter and receiver are well connected and that the power
indicator lights are ON
2.
If the display states, “Please check the TX input signal...”
First check to see if there input is properly connected and powered on. Next try to connect the signal source
directly to the display device to see if there is a signal output from the source device or change the signal
source.
3.
If the display is not stable:
•
Try moving the position of the transmitter and receiver and make sure the range of the device has not
been exceeded.
•
Hit the “RESET” button on the RX first, followed by the TX. Please allow time to sink before trying the TX
RESET button
•
Remove power and HDMI form both sides, reconnect the HDMI cables FIRST, then power after
•
Look to remove other wireless signal that may be disrupting the transmission