Optional Accessories:

Digital Camera Systems:

 

Part Number: 

Description:

 

1400-CDPC-10:  USB Digital Camera System, 10 Megapixels - for 1210- and 1220-series

 

1200-CDPC-10:  USB DIgital Camera System, 10 Megapixels - for 1230-series

 

1400-CDPC-5:  USB Digital Camera System, 5 Megapixels - for 1210- and 1220-series

 

1200-CDPC-5:  USB DIgital Camera System, 5 Megapixels - for 1230-series 

 

 

1400-CDPC-3:  USB Digital Camera System, 3 Megapixels - for 1210- and 1220-series

 

1200-CDPC-3:  USB DIgital Camera System, 3 Megapixels - for 1230-series

Other Accessories:

 

Part Number: 

 

Description:

 

Call for Part Numbers 

Eyepieces: 

10X, 16X, 20X

 

Call for Part Numbers 

Objectives:  Achromatic:   

 

4X, 10X, 20X, 40X, 100X(oil)

 

   

 

 

 

 

Plan Achromatic: 

 

4X, 10X, 20X, 40X, 100X(oil)

 

   

 

 

 

 

Achromatic Phase:   

10X, 20X, 40X, 100X(oil)

 

   

 

 

 

 

Plan Achromatic Phase: 

10X, 20X, 40X, 100X(oil)

 

1200-IOG   

 

Immersion Oil, Low Viscosity (1/4 oz. Bottle)

 

1200-PAK-38 

 

Polarizer & Analyzer

Parts & Accessories

For information about parts, accessories, or service -- contact your dealer directly or contact VanGuard 

Microscopes at 1-800-423-8842.

4

Содержание 1200CM Series

Страница 1: ...Covering Models 1210CM 1211CM 1220CM 1221CM 1222CM 1223CM 1230CM 1231CM 1232CM 1233CM Operation Manual 1200CM Series...

Страница 2: ...25 N A Abbe condenser Phase contrast models come with a 1 25 N A Zernike condenser with phase annulus rings for 10X 25X 40X and 100X also has a 0 setting for brightfield work All condensers are mount...

Страница 3: ...0X Plan Phase Objective 1 ea 20X Plan Phase Objective 1 ea 40X Plan Phase Objective 1 ea 100X Plan Phase Objective 1 ea Dispersion Filter 1 ea Blue Filter 1 ea Green Filter 1 ea Model 1230CM Trinocula...

Страница 4: ...xels for 1210 and 1220 series 1200 CDPC 3 USB DIgital Camera System 3 Megapixels for 1230 series Other Accessories Part Number Description Call for Part Numbers Eyepieces 10X 16X 20X Call for Part Num...

Страница 5: ...tering Knobs Brightfield only Aperature Iris Diaphragm Adjustment Lever Fine Focus Control Substage Collector Base Stand Mechanical Stage Slide Holder Slide Holder Knobs Focusing Tension Control Knob...

Страница 6: ...Fuse Holder Parts Accessories Phase Annuli Centering Knobs Phase Contrast Condenser Iris Diaphragm Adjustment Light Bulb Centering Mechanism Substage Collector Set Screw 6 Light Bulb Access Door Lock...

Страница 7: ...eyetubes see figure 2 After removing the objectives from their storage containers individually install each one into the nosepiece by threading them clockwise into the threaded holes of the nosepiece...

Страница 8: ...er will reduce the field so that a small white hexagon is visible within a black field see Figure 6A Focusing of the hexagon is performed by turning the coarse fine focus controls This white hexagon i...

Страница 9: ...nser assembly until the two rings of light are centered upon one another see Figure 8 Once the phase rings are centered remove the phase contrast centering telescope and replace with the eyepiece The...

Страница 10: ...to induce contrast into a specimen not to adjust light intensity The mechanical stage X Y controls located underneath the right hand side of the stage see figure 9 provide easy and accurate positionin...

Страница 11: ...icroscope Interpupillary and Diopter Adjustment 1 2 3 Interpupillary adjustment the distance between eyepieces is made through a folding action The Seidentopf design allows for a folding adjustment wh...

Страница 12: ...a adapter assembly until it is firmly secured with the camera port set screw Tighten the camera port set screw Pull the prism slider completely out to divert the image to the camera port The prism sli...

Страница 13: ...Models The 100X objective which comes with this microscope must be used with immersion oil in order to maintain image quality After use the objective tip needs to be wiped clean so that no oil residu...

Страница 14: ...lose the light bulb access door and screw the knob back in to lock Return the microscope to normal operating position If necessary recenter the illuminator following the instructions on page 9 1 2 7 6...

Страница 15: ...r ordering information The same care instructions apply to all optical parts on this VanGuard Microscope including the substage collector and the condenser lenses All other parts can be cleaned with a...

Страница 16: ...can t get enough light Step Possible Cause How to Check Result Solution For More Info 1 Variable lighting control VLC is turned down too far Visually inspect VLC turned up Go to next step VLC turned...

Страница 17: ...blockage Contact dealer or VanGuard Microscopes Page 17 I can t focus on the specimen Step Possible Cause How to Check Result Solution For More Info 1 Up stop set too low Visually inspect Set too low...

Страница 18: ...25 NA 8 0mm WD 1 8mm FOV Achromatic or Plan Achromatic 20X 0 40 NA 0 50mm WD 0 9mm FOV 40X 0 65 NA 0 40mm WD 0 45mm FOV 100X oil 1 25 NA 0 25mm WD 0 18mm FOV Stage Dimensions 125mm x 135mm Stage Motio...

Страница 19: ...19 Notes...

Страница 20: ...Printed in the USA No VGMNL070319 1200CM...

Отзывы: