MS-451PV Calibration Manual Ver. 1.01E
7
I N I T M A I N T E 1
K E Y C H E C K
I N I T M A I N T E 6
T E M P C A L I B R AT E
S E T T I M E
1 . 5 s
S E T 1 4 0 F
4
Adjust the heating temperature at the 14 adjustment points.
Measure the peak temperature of each seal as the machine
operates automatically, and input the “adjustment value”.
5
Enter to the initial maintenance mode by turning ON the power
while holding the ENTER key and 0 (zero).
6
The right display will be shown on the screen.
7
Show “INITIAL MAINTE 6 TEMP CALIBRATE” on the display by
using the UP key, and press ENTER key to select the menu.
8
Set the heating time during heat temperature calibration using
numeriO keys.
[ Setting range: 0.0 to ˤ.0 seconds ]ƻNjsǣǣ
ǼÌsrŗǻrNJĨsɴǼŸOŸŘ ÞNjŎǼÌsǣsǼǼÞضʳ
9
ǻÌsʩNjǣǼ_ĠȖǣǼŎsŘǼƼŸÞŘǼˠˣ˟°
F
will be shown on the screen.
Adjustment Points
1
2
3
4
5
6
7
8
9
10
11
12
13
14
[°
F]
140 160 180 200 220 240 260 280 300 320 340 360 380 400