5.2  Operating on 0-10V external setting signal 

When the cable between 10V and E1 has not been connected, the fan needs to be controlled through 
an external setting signal (0-10V). 
 

 

 
Figure 9 depicts the characteristic curve of the fan’s motor torque to the specifications of the external 
setting signal. 

 

Figure 9 FG035 motor characteristic curve (0 - 10 V setting signal) 

 

5.3  Prerequisites for commissioning  

Before first-time start-up of the Verti-Fan, check the following: 

 

Has any leftover installation material and other foreign material been removed from the fan 
area? 

 

Are the plastic hose, mounting ring and hose clamp correctly mounted to the fan, safety 
devices according to (EN ISO 13857)? 

 

Check the rotat. direction (see the rotat. direction arrow on the fan blade, impeller base plate 
or intake-side support plate). 

 

Check for quiet, low vibration operation. Strong vibrations due to erratic operation 
(unbalanced), e.g. caused by transportation damage or improper use, can lead to failure. 

 
For more information concerning the fan consult the FG035 user manual 
 

 

Содержание Verti-Fan EC

Страница 1: ...Page 1of 28 Vertical air circulation Version 2023 05 Verti Fan EC MANUAL...

Страница 2: ...d maintain these fans The manual and operating instructions are compiled together in a single document Each chapter has a number and where necessary chapters that are divided into sections The table o...

Страница 3: ...rackets 10 4 2 1 Contents of lowered installation package 10 4 2 2 Mounting of brackets to fan 10 4 2 3 Mounting bracket to truss 10 4 3 Method with the aid of a steel cable 12 4 3 1 Content of cable...

Страница 4: ...steel ring or oval can be optionally attached to the end of this hose The Verti Fan is optionally fitted with a power cord and plug The Verti Fan has no operating controls 1 1 2 Specifications Genera...

Страница 5: ...nents Figure 1 Diagram of the Verti Fan showing the main components and their names Nr Part name 1 Mounting brackets optionally replacable with cable mounting 2 Fan 3 Mounting ring 4 Mounting brackets...

Страница 6: ...be at least 300 mm clearance on the suction side of the fan If a shade screen is used this means that the fan has to be installed lower than the lowest truss and the mounting brackets adapted It must...

Страница 7: ...the Verti Fan is simple a horizontally placed fan draws air in at the top of the greenhouse and blows it down through a plastic hose The plastic hose is kept open at the bottom by a stainless steel ri...

Страница 8: ...there is a danger that parts may vibrate loose and fall off Mind the fact that it takes a couple of seconds for the fan to start working when it has been turned on In compliance with EN ISO 13857 a p...

Страница 9: ...he description are referring to Figure 1 on page 5 Table 2 Contents of the installation package Figure 2 Mounting ring Verti Fan with lowered installation left and cable installation right Quantity De...

Страница 10: ...in good condition o Check for an electrical connection which is sufficiently close Before the fan can be attached to the trellis the lowered and mounting brackets and spacer must be fixed to the fan...

Страница 11: ...ing ring C 4x stainless steel mounting bracket with spacer B 4x Stainless steel hex bolt m6x20 I 4x stainless steel washer m6 J 4x stainless steel washer m6 J 2 4x stainless steel self locking nut m6...

Страница 12: ...exagonal nut M6 Q see figure 5 right side o Fixate two of the mounting brackets and spacers B by means of 2x bolt M6x20 O 4x bodywork washer M6 P and 2x hexagonal nut M6 Q see figure 5 left side Use p...

Страница 13: ...nting brackets spacers to the fan by means of bolts left and eye bolts right 2x eye bolt M6 x 80 N 8x Fender washer M6 P 4x wire clamp S 4x hexagonal nut M6 Q cable R 1x hose clamp D 1x mounting ring...

Страница 14: ...Page 14 of 28 Figure 6 Schematic drawing of a Verti Fan suspended with the aid of a steel cable...

Страница 15: ...retainer G facing towards the inside of the hose Slide the other end of the hose over the underside of the mounting ring I Place the hose clamp D around the mounting ring C and hose E and tighten The...

Страница 16: ...be turned off on when it receives a supply voltage This cable needs to be connected before installation by the installer Connect the line voltage to PE L1 and N Here it must be strictly observed that...

Страница 17: ...ime start up of the Verti Fan check the following Has any leftover installation material and other foreign material been removed from the fan area Are the plastic hose mounting ring and hose clamp cor...

Страница 18: ...e is dirty clean it with a dry brush and then wipe down with a damp cloth If the fan blades or fan housing are dirty wipe down with a damp cloth Replace the capacitor after 10 000 operating hours This...

Страница 19: ...remove foreign objects dirt in the fan Active temperature management is activated motor or electronics overheated Check whether the airways are free if necessary remove foreign objects See Impeller i...

Страница 20: ...g is disconnected to prevents unintended and unwanted starting of the fan Make sure the workplace is safe then remove the self locking nuts of the U clamps or if using cables unhook the Verti Fan from...

Страница 21: ...this declaration relates is in conformity with the following directives It is also where appropriate in conformity with the following standards or other normative documents n a Van der Ende Pompen Aa...

Страница 22: ...and their admendments It is also where appropriate in conformity with the following standards or other normative documents n a Van der Ende Pompen Aartsdijkweg 23 2676 LE Maasdijk The Netherlands Ver...

Страница 23: ...Page 23 of 28 ATTACHMENTS A CE declaration concerning fan B UKCA declaration concerning fan C Wiring scheme FG035 Fan...

Страница 24: ...Page 24 of 28 CE declaration concerning fan...

Страница 25: ...Page 25 of 28 UKCA declaration concerning fan...

Страница 26: ...Page 26 of 28 Wiring scheme FG035 Fan...

Страница 27: ...Page 27 of 28...

Страница 28: ...Page 28 of 28 Aartsdijkweg 23 2676 LE Maasdijk The Netherlands 31 174 51 50 50 info vanderendegroup com www vanderendegroup com...

Отзывы: