SECTION 5

TROUBLESHOOTING

1. DECREASED PERFORMANCE - High desiccant usage.

High inlet air temperatures.

 Check the aftercooler performance.  Make sure that the

aftercooler was properly sized and installed.  Check the aftercooler

operation manual for further details.

 If an aftercooler was not installed, one may be required.

 Check the compressor capacity or air usage vs. the dryer rating.

 Was a different compressor installed?

High ambient temperatures.

Check the location of the dryer for changes in ambient tempera-

tures.

Was the dryer moved to a different location?

Was a piece of equipment or piping installed near the dryer that

caused an increase in ambient temperatures?  Relocate the dryer

or equipment if possible.  If relocation is not possible, correct the

ambient temperature.

Dryer overloaded.

Check the flow through the dryer.  Check the flow at peak usage

periods.  Have the flow requirements of the system increased?

Was the dryer properly sized for the actual operating conditions?

Check the capacity of the dryer for the system conditions.   If the

system requirements exceed the dryer's capability, a larger dryer

must be installed.

Desiccant bed below required level.

Check the desiccant bed level.  The level should be checked at

least once a month.  The usage of desiccant will vary with the

operating conditions and the type of desicccant being used.  The

dryer will require more desiccant during the warmer months of the

year.

Desiccant quantities and filling procedures are outlined in Section

4.4 of this manual.

2. LIQUID DOWNSTREAM OF THE DRYER.

Improper draining.  The dryer may be flooded.

The dryer must be drained at least once for every 8 hours of

operation.

Check the drain valve(s) and piping for clogs.  Repair or replace

faulty valves.  If the piping is clogged, it must be cleared.

If the dryer is installed outdoors where ambient temperatures fall

below freezing, the drain line and valve(s) may freeze.  If ambient

temperatures fall below freezing, the drain line can be wrapped

with heat tracing and/or insulation to prevent freezing.

If maintaining the required draining schedule is a problem, an

automatic ball type drain valve should be installed.  Reference

Section 2.2-F in this manual for installation instructions.

IMPORTANT: Never install a float type or solenoid type drain valve

on this dryer.

Bypass valve open or faulty.

Check the dryer bypass valve.  It might be faulty or open allowing

untreated air to enter the air system.

Low or no desiccant in the dryer.

Check the dryer deissiccant bed level.  Reference Section 4.4 for

filling quantities and procedures.

3. DECREASED PERFORMANCE - low desiccant usage.

The desiccant bed may be contaminated.

The dryer will tolerate normal amounts of compressor lubricant.  If

the compressor manufacturer's recommended lubrication rate is

exceeded, the desiccant bed can become contaminated with

compressor lubricants.

Periodically check the desiccant bed.  If the tablets are discolored

(deep yellow or brown), the bed may be contaminated.

If the bed has become contaminated, it can be flushed with an

adequate supply of water.  Depending upon the severity of

contamination, it might be necessary to completely flush the entire

bed from the dryer and replace it with new desiccant.

Check the compressor for proper operation.  The compressor

might be worn or over lubricated.  Check the compressor

operator's manual and correct.

Check the atmospheric air near the compressor air intake.  Heavy

concentrations of acid fumes or smoke and dust will cause

contamination if they are drawn into the air system.  Check or

install a filter on the compressor intake.

If it is not possible to reduce the amount of lubricants in the air

system, a separator and/or coalescing filter should be installed

before the dryer.

If the above check list does not remedy the problem, consult your local VAN AIR distributor or call

 the VAN AIR factory  in Lake City, Pennsylvania   PHONE  (814) 774-2631 or FAX (814) 774-3482.

Содержание D-42

Страница 1: ...AIR AUTHORIZED PARTS ONLY DO NOT REMOVE REPAIR OR REPLACE ANY ITEM ON THE DRYER WHILE IT IS UNDER PRESSURE DEPRESSURIZE THE DRYERCOMPLETELYBEFORESTARTINGINSTALLATIONAND OR MAINTENANCE PROCEDURES SERI...

Страница 2: ...rges through the dryer If the ambient temperature around the receiver is higher than the outlet air temperature from the aftercooler locate the dryer between the aftercooler and the receiver 2 1 F SPE...

Страница 3: ...49 2000 3398 2500 4248 3000 5097 3500 5947 4000 6796 4500 7646 125 PSIG 8 6 Bar 1522 2587 1827 3104 2436 4139 3045 5173 3654 6208 4263 7243 4872 8277 5481 9312 150 PSIG 10 3 Bar 1795 3050 2154 3659 28...

Страница 4: ...PES OF DRAINS TO FAIL THUS RESULTING IN FLOODING OF THE DRYER The drain of the dryer can be remotely piped away from the dryer DO NOT connect the drain line to a pressurized line Make sure that the li...

Страница 5: ...9mm 18 7 16 468 3mm 20 11 16 525 5mm 20 11 16 525 5mm E 27 13 16 706 4mm 31 7 8 809 6mm 34 3 8 873 1mm 35 5 16 896 9mm 36 3 8 923 9mm 36 15 16 938 2mm 41 1 2 1054 1mm 41 1 2 1054 1mm F 1 NPT 1 NPT 1 N...

Страница 6: ...he air supply lines 3 2 OPERATING THE DRYER The simple design of the single tower dryer allows for easy operation The dryer requires two procedures to ensure peak performance On a new installation con...

Страница 7: ...he hatch cover to be installed Check the condition of the hatch covet If is damaged it must be replaced The gasket should be replaced every time Check the sealing surface of the opening If it is conta...

Страница 8: ...2391 1085 2789 1265 Lbs In of bed 52 7 23 9 68 3 31 0 86 5 39 2 106 6 48 4 128 7 58 4 153 4 69 6 179 4 81 4 209 3 94 9 MIN Level 949 430 1229 557 1557 706 1919 870 2317 1051 2761 1252 3229 1465 3767 1...

Страница 9: ...freezing the drain line and valve s may freeze If ambient temperatures fall below freezing the drain line can be wrapped with heat tracing and or insulation to prevent freezing If maintaining the req...

Страница 10: ...TOP RING SECTION D 54 TOP RING SECTION D 60 TOP RING SECTION D 66 TOP RING SECTION D 72 TOP RING SECTION D 78 TOP RING SECTION D 84 TOP RING SECTION D 42 GRID TUBES D 48 GRID TUBES D 54 GRID TUBES D...

Страница 11: ...PAGE 11 SECTION 6 REPLACEMENT PARTS...

Страница 12: ...ake City PA 16423 2095 Phone 814 774 2631 Fax 814 774 3482 YOUR VAN AIR REPRESENTATIVE IS NAME COMPANY ADDRESS CITY STATE ZIP PHONE FAX ATTACH BUSINESS CARD HERE Air Vacuum Process Inc 14090 FM 2920 S...

Отзывы: