VALPRO VP29S-HC Скачать руководство пользователя страница 3

    

    

    

    

                                         

 

                                   

For warranty service, call 1-888-VALPRO-8 / 1-813-502-0300                                                                   

 

Service and Installation Manual

T

he appliance use flammable insulation blowing gas C5H10, disposal of the appliance shall in accordance 

 

with the regulations of local authorities. 

T

he key for appliance electric box should be safe kept by qualified persons in order to avoid a hazard   

 

WARNING

:  Keep  ventilation  openings,  in  the  appliance  enclosure  or  in  the  built-in  structure,  clear  of 

 

obstruction. 

WARNING

: Do not use mechanical devices or other means to accelerate the defrosting process, other than 

 

those recommended by the manufacturer. 

WARNING

: Do not damage the refrigerant circuit. 

WARNING

: Do not use electrical appliances inside the food storage compartments of the appliance, unless 

 

they are of the type recommended by the manufacturer. 

Exercise care handling, moving, and use of the refrigerator or freezer to avoid either damaging the 

refrigerant tubing, or 

 

increasing the risk of a leak. 

L

’opération, le mouvement et l’utilisation du réfrigérant ou le congélateur doivent éviter les dommages du 

 

tuyau réfrigérant ou le rique de la fuite. 

C

aution – Risk of Fire or Explosion due to Flammable Refrigerant Used. Follow Handling 

Instructions Carefully in Compliance with U.S. Government Regulations. 

C

omponent  parts  shall  be  replaced  with  like  components  and  that  servicing  shall  be  done  by  factory 

 

authorized  service  personnel,  so  as  to  minimize  the  risk  of  possible  ignition  due  to  incorrect  parts  or 

 

improper service. 

Les pièces de rechange doivent être remplacées par les components relatifs et les opérations doivent être 

 

faites par les professionnels afin de minimaliser le risque d’allumage à cause des parts incorrects ou des 

 

opérations impropres. 

C

AUTION – Risk Of Fire Or Explosion Due To Puncture Of Refrigerant Tubing; Follow Handling Instructions 

 

Carefully. Flammable Refrigerant Used 

D

ANGER: Risk of child entrapment. Before you throw away your old refrigerator or freezer: 

Take off the doors 

Leave the shelves in place so that children may not easily climb inside.

 

 

 

 

 

Содержание VP29S-HC

Страница 1: ...op Refrigerators and Freezers Service Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment Notify carrier of damage Inspect all compon...

Страница 2: ...y messages will alert you to potential hazards advise to reduce the chance of injury and let you know what can happen if the instructions are not followed If the supply cord is damaged it must be repl...

Страница 3: ...ing or increasing the risk of a leak L op ration le mouvement et l utilisation du r frig rant ou le cong lateur doivent viter les dommages du tuyau r frig rant ou le rique de la fuite Caution Risk of...

Страница 4: ...quipment is packaged to prevent damage in transit if goods have been shipped via 3rd party merchandise must be inspected before accepting shipment Valpro assumes no responsibility for damage while in...

Страница 5: ...AN 1 6 Size HP SHELF CAPACITY Sq ft BTU CHARGE OZ SHIP WEIGHT LBS NEMA PLUG VP29S HC 115 60 1 3 7 8 1 3 14 853 3 0 276 5 15P VP48S HC 115 60 1 4 3 12 12 1 2 26 1365 3 17 313 5 15P VP60S HC 115 60 1 4...

Страница 6: ...ions near stoves and ovens It is recommended that the unit be installed no closer than 2 from any wall Leveling A level cabinet looks better and will perform better because the doors will line up with...

Страница 7: ...ain optimum refrigeration temperature Top section is not intended for overnight storage Product should be removed from pans Pans can remain in cabinet if empty Defrosting Every 6 hours the unit will t...

Страница 8: ...r enabled Flashing Programming phase Indicators flashing Anti short cycle delay enabled UP ARROW Display last temperature alarm In programming mode browse parameter codes In programming mode increase...

Страница 9: ...HOW TO START A MANUAL DEFFROST Push the key for more than 2 seconds and a manual defrost will start 2 4 HOW TO LOCK THE KEYBOARD 1 Hold the and keys for more than 3s 2 The POF message will be displaye...

Страница 10: ...Failure to maintain a clean condenser coil can initially cause high temperatures and excessive run times Continuous operation with dirty or clogged condenser coils can result in compressor failures N...

Страница 11: ...can cause them to become brittle and prevent proper seals Do not use sharp tools or knives to scrape or clean the gasket which could possibly tear the gasket and rip the bellows Gaskets can easily be...

Страница 12: ...L VPUCR48 VPUCR60 PLUG THERMOSTAT DISPLAY ROOM EVAP SENSOR CONDENSEN FAN OVERLOAD PROTECTOR COMPRESSOR CURRENT RELAY STARTING CAPACITOR FAN POWER EVAP FAN DOOR SWITCH L N PLUG THERMOSTAT DISPLAY ROOM...

Страница 13: ...ERMOSTAT DISPLAY CONDENSER FAN MOTOR OVERLOAD PROTECTOR COMPRESSOR PTC STARTER CIRCUITALION FAN MOTOR t L N ROOM EVAP SENSOR DOOR FRAME HEATER M M L N THERMOSTAT DISPLAY PLUG CIRCUITALION FAN MOTOR OV...

Страница 14: ...ITALION FAN MOTOR ROOM EVAP SENSOR THERMOSTAT DISPLAY DOOR FRAME HEATER CONDENSER FAN MOTOR OVERLOAD PROTECTOR COMPRESSOR t PTC STARTER L N M M L N PLUG CIRCUITALION FAN MOTOR ROOM EVAP SENSOR DOOR FR...

Страница 15: ...2SM HC PLUG CIRCUITALION FAN MOTOR THERMOSTAT DISPLAY ROOM EVAP SENSOR DOOR FRAME HEATER MIDDLE FRAME HEATER MIDDLE FRAME HEATER CONDENSER FAN MOTOR OVERLOAD PROTECTOR COMPRESSOR PTC STARTER t L N PLU...

Страница 16: ...SOR CONDENSEN FAN THERMAL CUT OFF DEFROST HEATER OVERLOAD PROTECTOR COMPRESSOR CURRENT RELAY STARTING CAPACITOR MIDDLE FRAME HEATER FAN POWER EVAP FAN DOOR SWITCH N L PLUG THERMOSTAT DISPLAY ROOM EVAP...

Страница 17: ...Service and Installation Manual For warranty service call 1 888 VALPRO8 1 813 502 0300 17 WIRING DIAGRAM MODEL VPUCR27...

Страница 18: ...Service and Installation Manual 18 For warranty service call 1 888 VALPRO8 1 813 502 0300 WIRING DIAGRAM MODEL VPUCR48 VPUCR60...

Страница 19: ...Service and Installation Manual For warranty service call 1 888 VALPRO8 1 813 502 0300 19 WIRING DIAGRAM MODEL VP29S HC VP29SM HC...

Страница 20: ...Service and Installation Manual 20 For warranty service call 1 888 VALPRO8 1 813 502 0300 WIRING DIAGRAM MODEL VP48S HC VP48SM HC VP60S HC VP60SM HC...

Страница 21: ...Service and Installation Manual For warranty service call 1 888 VALPRO8 1 813 502 0300 21 WIRING DIAGRAM MODEL VP72S HC VP72SM HC...

Страница 22: ...Service and Installation Manual 22 For warranty service call 1 888 VALPRO8 1 813 502 0300 WIRING DIAGRAM MODEL VPP47...

Страница 23: ...Service and Installation Manual For warranty service call 1 888 VALPRO8 1 813 502 0300 23 WIRING DIAGRAM MODEL VPP71...

Страница 24: ...Service and Installation Manual 24 For warranty service call 1 888 VALPRO8 1 813 502 0300 WIRING DIAGRAM MODEL VPP94...

Страница 25: ...Service and Installation Manual For warranty service call 1 888 VALPRO8 1 813 502 0300 25 WIRING DIAGRAM MODEL VPUCF27...

Страница 26: ...Service and Installation Manual 26 For warranty service call 1 888 VALPRO8 1 813 502 0300 WIRING DIAGRAM MODEL VPUCF48 VPUCF60...

Страница 27: ......

Страница 28: ...Valpro Commercial Refrigeration 203 Kelsey Ln Building G Tampa Florida 33619 Email info valpromail com http www valprorefrigeration com...

Отзывы: