manualshive.com logo in svg
background image

3) Start Body Analysis

Stand straight and keep both feet flat on the strain gauge sensor. Wait until weight is shown 
on display is stable and locked. The number will flast 3 times and then enter calculation state.
                   . When the Body fat analysis is flashing, you can then step off from the scale.

All measure Values will be shown twice alternately in 60 seconds (4 seconds intervals). The 
scale will then switch off automatically.

3) Alarm Prompt

Low battery:

 When battery is low, the display will show ‘LO’ symbol. Please install new 

battery for accurate measures. 

Over-load:

 When the weight value exceeds the measured values, the display will show ‘O-Ld’.

Error:

 When display show ‘ERR’, please take note of the following:

           1) Not bare feet for indentifying body fat measurement.
           2) Steping off the scale before body fat analysis procedure is complete.
           3) Feet are not place on strain gauge sensor for body fat measurement.
           4) The soles of your feet are not clean, 

eg. Feet perspiration etc.

           5) Exceed weight range.

mus

BONE

kg

SET

%

water

SET

KCAL

SET

%

SET

BMI

SET

kg

SET

SET

Содержание VF-005

Страница 1: ...using your Body Composition Monitor Note Pregnant women should not use this monitor and if you have a pacemaker or other internal electronic medical device Specifications Package Contents Full body composition scan BMI parameter Body weight Body fat analysis Body water analysis Body bone analysis Body muscle analysis Calories analysis 10 user memory LCD display screen size 78 x 38mm Weight Capacit...

Страница 2: ...ur body fat percentage and other physical data Press Set to turn on display for user selection P0 P9 Press Up or Down to change the user number press Set again to select gender Press Up or Down to change the gender press Set again to select age Press Up or Down to change age press Set again to select height Press Up or Down to change height press Set again to complete Display will indicate 0 0kg i...

Страница 3: ...y 3 Alarm Prompt Low battery When battery is low the display will show LO symbol Please install new battery for accurate measures Over load When the weight value exceeds the measured values the display will show O Ld Error When display show ERR please take note of the following 1 Not bare feet for indentifying body fat measurement 2 Steping off the scale before body fat analysis procedure is compl...

Страница 4: ...composition monitor and contact us immediately via email at v info valore sg or return this product to the store where you have purchased it from If the product produces an abnormal smell high temperature low temperature during normal use discolours or changes shape abnormally stop using the product and contact us immediately via email at v info valore sg DISCLAIMER TRADEMARKS All information trad...