Page 10
bolt and position the deflector as
in figure 3, securing it using the
nut and washer. It MUST be
sealed against the top of the stove
casting. It is important that it sits
on top and between the raised
cast areas on the rear of the stove
body (See figure 3). The flue
spigot is screwed to the cast collar
and clamps the flue restrictor plate
in place (See figure 2).
Thermal switch.
The thermal switch should be fitted to the inside of the diverter box as in figure 4.
Secure using the nut and bolt supplied. Never modify the fixing bracket and always
ensure that the switch is fitted correctly. NEVER USE THE STOVE IF THE THERMAL
SAFETY SWITCH HAS BEEN REMOVED OR IF IT IS DAMAGED IN ANY WAY.
Burner module.
Unpack the burner
module.
Secure the control
knob assembly to the
gas valve, the screw
tail should secure onto
the flat on the gas
valve spindle.
Secure the rear leg
at the back of the stove
base using two No.4 x
10mm screws supplied
(See figure 5).
Offer the burner module into
the stove and connect the
thermal switch leads to the tags
mid way along the
thermocouple.
©
Baxi Heating U.K. Limited 2010.
INSTALLER GUIDE
Figure 5.
Figure 4.
Figure 3.
Содержание Vega 200 Gas