Valor Ultimate Скачать руководство пользователя страница 30

Page 30

8.

Recommend that the appliance should be serviced and the chimney inspected by a

competent person (In the UK a CORGI registered person) at least annually.
If the appliance is in premises in the United Kingdom occupied by a tenant, point out
that by law a landlord must have any gas appliance, flue and pipework which is situated
in a tenant’s premises checked for safety at least every 12 months.

9.

Advise the customer that the castings, front surround, firebox and ceramic pieces can

be cleaned as described in the user’s instructions and that the loose ceramic fuel effect
pieces must be replace as described in those instructions.

Stress that no extra coals must be added over and above those supplied with the
appliance and that any replacements must only be the authorised spares.  Warn that
ignoring this advice could cause incomplete clearance of the products of combustion
with consequent health hazards.
10.

Inform the customer that the Serial number for the appliance is located on the

metal plate, located behind the lower front casting and underneath the burner. 

11.

Hand the literature pack with this guide to the customer.

17. SERVICING & PARTS REPLACEMENT

Always turn off the gas supply before commencing any servicing (The appliance
inlet “T” connector incorporates an isolating valve).
It is recommended that, at least once a year, the appliance is disconnected and the
fireplace opening checked and cleared of any debris. 
This product uses fuel effect pieces and a burner compartment rear wall
containing Refractory Ceramic Fibres (RCF), which are man-made vitreous
silicate fibres. Excessive exposure to these materials may cause irritation to eyes,
skin and respiratory tract. Consequently, it is important to take care when
handling these articles to ensure that the release of dust is kept to a minimum. To
ensure that the release of fibres from these RCF articles is kept to a minimum,
during installation and servicing we recommend that you use a HEPA filtered
vacuum to remove any dust and soot accumulated in and around the fire before
and after working on the fire. When replacing these articles we recommend that
the replaced items are not broken up, but are sealed within a heavy duty polythene
bag, clearly labelled as RCF waste. This is not classified as “hazardous waste” and
may be disposed of at a tipping site licensed for the disposal of industrial waste.
Protective clothing is not required when handling these articles, but we recommend
you follow the normal hygiene rules of not smoking, eating or drinking in the work
area and always wash your hands before eating or drinking.

Check that the appliance is clean and that soot or debris is not blocking the gaps

INSTALLER GUIDE

Содержание Ultimate

Страница 1: ...National call rates apply in the United Kingdom In the Republic of Ireland call 0044 08706 061 065 INSTALLER Please leave this guide with the owner Valor Heating Ultimate Model 717 GC No 32 032 52 INS...

Страница 2: ...a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation Valor is a CORGI registered company All our gas fires must...

Страница 3: ...hecks 22 10 2 1 Lighting the burner 22 10 2 2 Operating the burner 22 10 3 Reference Pressure Check 23 11 FITTING THE FRONT SURROUND 23 12 CERAMIC COALS INSTALLATION 24 13 FIREFRONT CASTING8INSTALLATI...

Страница 4: ...ance When lifting always keep your back straight Bend your legs and not your back Avoid twisting at the waist It is better to reposition your feet Avoid upper body top heavy bending Do not lean forwar...

Страница 5: ...or the disposal of industrial waste Protective clothing is not required when handling these articles but we recommend you follow the normal hygiene rules of not smoking eating or drinking in the work...

Страница 6: ...the following British Standards BS 715 BS 1251 BS 1289 Part 1 BS EN 1806 BS 4543 Part 2 BS 5440 Part 1 BS 5440 Part 2 BS 5871 Part 1 BS 6461 Part 1 BS 6891 In England and Wales the current edition of...

Страница 7: ...nce from the base of the fireplace opening in the wall to the finished floor level is at least 72mm 3 2 2 To a fireplace incorporating a metal flue box conforming to BS715 with a minimum internal dept...

Страница 8: ...ng This may cause cracking of the surround back or marble 3 3 The following flues are suitable 225mm x 225mm conventional brick flue If a flue liner is used it must be a minimum of 125mm diameter The...

Страница 9: ...uel the flue must be swept clean prior to installation All flues should be inspected for soundness and freedom from blockages 3 8 If the fireplace opening is an underfloor draught type it must be seal...

Страница 10: ...a bath or shower or where steam is regularly present 3 14 An extractor fan may only be used in the same room as this appliance or in any area from which ventilation for the appliance is taken if it d...

Страница 11: ...t touch the surround See figure 4 We suggest that the actual surround is used as a template to mark the area for combustible cladding removal and that this area is increased by at least 2mm all round...

Страница 12: ...shut the appliance down if an unacceptable amount of harmful products of combustion accumulate Under no circumstances should the A S D be altered or bypassed in any way Only a genuine manufacturers re...

Страница 13: ...surround 1 Firefront casting 1 Front cover casting Remove all the items carefully to prevent damage Take special care when handling the ceramic components Some items may be contained in the packaging...

Страница 14: ...ogether with secondary fixing to the fireplace floor The methods are detailed in section 9 of this manual Before selecting the retention method consult with the customer Method 2 is provided for insta...

Страница 15: ...ng to install it is worth checking that the ignition system performs satisfactorily Set the control knob to the off position Depress the control knob and rotate it anticlockwise to the pilot ignition...

Страница 16: ...n by the Debris catchment area Note that the areas are different for fireplaces with conventional brick flues and precast flues 2 Place the template on the fireplace floor printed side upward with the...

Страница 17: ...n seals to the bottom edges of the convection box side flanges See figure 9 IMPORTANT Before continuing with the installation of this gas fire the aeration setting on the burner must be checked The ae...

Страница 18: ...pliance is supplied with a flue restrictor for use where the flue draught is excessive The restrictor must not be fitted where a precast flue or a 125mm flue liner is used For flue liners greater than...

Страница 19: ...rawlplug into each hole 6 Place the convector box back in position in the fireplace 7 Fit a woodscrew through each hole in the convector box flanges and tighten to seal the box to the fireplace surrou...

Страница 20: ...the holes See figure 15 Give the cables a pull so that they grip against the convection box flanges 6 Thread the cables through the upper eyebolts in the rear wall and then through the lower eyebolts...

Страница 21: ...e tension on the cables by slackening the screws and turning the hexagonal adjusters fully anticlockwise The convection box should then automatically realign itself Pull each cable taut again and push...

Страница 22: ...the pilot ignition position A click will be heard as the integral piezo operates A spark should be seen between the electrode and pilot tip 2 Turn the control knob clockwise to the Off position Repea...

Страница 23: ...checking turn off the appliance Remove the pressure gauge and replace the test point sealing screw 3 Relight the appliance Turn to the maximum output position and test around the sealing screw for gas...

Страница 24: ...e amount of movement will be negligible See figure 22 2 Place the front base coal in the firebox with its bottom front locating over the front rim of the firebox Pull the coal forward so that it locat...

Страница 25: ...n the front and rear base coals as shown in figure 25 The letter B should be upright 5 Place a type A coal between the front and rear base coals with the letter A upright The top of the coal should re...

Страница 26: ...sting so that it rests on the hearth See figure 29 Black chrome front casting Place the fire front casting in front of the appliance 2 Place the bottom front cover casting in position below the fire f...

Страница 27: ...htly to get past the pilot ignition position The main burner should now light Depress the control knob slightly to release from the HIGH position and turn back clockwise to LOW While turning the burne...

Страница 28: ...n repeat the test If the smoke is still not drawn into the appliance inspect the sealing to the fireplace surround If the sealing is satisfactory but the appliance is installed with the flue restricto...

Страница 29: ...e fire 3 Explain to the customer that the appliance has a flame failure and spillage monitoring system Point out the explanation of this system shown in the owner s guide Advise that if the fire goes...

Страница 30: ...let T connector incorporates an isolating valve It is recommended that at least once a year the appliance is disconnected and the fireplace opening checked and cleared of any debris This product uses...

Страница 31: ...st the aeration setting loosen the two aeration shutter screws slide the aeration shutter to the position shown in figure 31 and tighten the fixing screws 17 2 To Remove the Fire Front Surround 1 Remo...

Страница 32: ...he pilot unit 4 Detach the thermocouple from the gas valve 5 Detach the electrode lead from the underside of the electrode tab 6 Remove the two screws securing the pilot unit See figure 34 7 Refit in...

Страница 33: ...t 10 Remove the gas valve 11 Refit in the reverse order 17 6 To Replace the Burner See figure 36 1 Remove the burner unit See section 17 3 2 Support the elbow injector and unscrew the injector nut 3 R...

Страница 34: ...fire retention is as method 1 See section 9 1 of installation instructions remove the screws If the fire retention is as method 2 See section 9 2 of installation instructions slacken the hexagonal ad...

Страница 35: ...Gas tap spark generator 1 3002983 C Spark generator and circlip 1 5108923 D Control knob 1 0545979 E Pilot unit For Natural Gas Appliances Pilot injector RBM 180 02 For Propane Appliances 1 3002988 51...

Отзывы: