29

15.2

To Remove The Front Surround

15.2.1

Remove the bottom front cover casting

.

15.2.2

Lift the fire front casting up and forward to release the locating

screw heads at the back of the casting from the keyholes in the surround
sides. Lift the casting clear.

15.2.3

Remove the two screws securing the bottom of the front surround

to the sides of the convection box.
Raise the front surround to allow the retaining lugs at the top to clear the
slots in the convection box hood and then lift clear (see figure 45).

15.2.4

Replace in the reverse order.

15.3

To Remove The Pilot Unit

15.3.1

Remove the 5 loose coals, ceramic side walls, front base coal, rear

base coal and ceramic back wall.

15.3.2

Remove the front surround unit - See section 15.2

.

15.3.3

Support the inlet isolating elbow to avoid straining the pipework

and disconnect the appliance from the elbow

.

15.3.4

Detach the burner unit from the convection box by removing  2

screws (see figure 46). Carefully lift the burner unit forward
making sure that the unit does not snag on any leads. Rest the
burner on its front face to allow access to the pilot and gas tap.

15.3.5

Disconnect the electrode lead from tab underneath the

electrode.

15.3.6

Undo the thermocouple nut at the gas tap .

15.3.7

Disconnect the pilot pipe from the pilot unit elbow.

15.3.8

Remove the first screw

 s

ecuring the dust cage to the

 

pilot

unit/burner (see figure. 47). Carefully remove the dust cage and
place aside.

15.3.9

Remove the second screw securing the

 

pilot unit to the burner. Remove

the pilot unit and place it aside.

15.3.10

Refit in the reverse order. Make sure that no leads are trapped.

Note 1 The pilot unit must be replaced as a whole assembly. Its individual components

are not separately replaceable.

 

2. Once removed, ensure that the dust cage is cleaned before refitting. Make sure that it

locates squarely onto the pilot unit without any gaps between the cage edges and the pilot

unit.

15.4

To Completely Remove The Burner Unit

15.4.1

Remove the ceramics and front surround, disconnect the

appliance and detach the burner unit from the convection box as
sections 15.3.1 to 15.3.4.

15.4.2

Detach the burner wiring loom connection at the right side of

the burner (see figure 48).

15.4 .3

Refit in the reverse order. Make sure no leads are trapped.

 

Figure 48 Burner loom connector

      

 

Figure 47 Pilot unit fixings

(Dust cage not
shown for clarity)

 Figure 46 Burner fixing points

 

Figure 45 Front surround

removal

Содержание Ultimate Turbochim BR517S

Страница 1: ...y GB Patent 2 202 622B 600B313 02 M ODEL BR517S G C 3 2 0 3 2 1 2 ULTIM ATE TURBOCHIM S i d e F a n F l u e d I n s e t G a s F i r e I N S T A L L E R G U I D E Please keep in a safe place for future...

Страница 2: ...lephone 0345 626341 Local call rates apply P l e a s e l e a v e t h i s I n s t a l l e r G u i d e w i t h t h e u s e r As supplied this appliance is for use with natural gas G20 When converted usi...

Страница 3: ...25 Full operating checks 26 27 Control settings check 26 Spillage check 26 27 Flame supervision monitoring system check 27 Final review 28 Servicing parts replacement 29 32 Burner plaques replacement...

Страница 4: ...Btu h 6 1kW 20 800Btu h Input Min Gross 2 2kW 7 500Btu h 3 6kW 12 280Btu h Output Max 3 12kW 10 600Btu h 3 6kW 12 280Btu h Output Min 1 1kW 3 750Btu h 1 8kW 6 140Btu h Burner Test Pressure Cold 18 2 0...

Страница 5: ...ent and the Welsh Office or the Building Standards Scotland Regulations issued by the Scottish Development Department c All relevant codes of practice d The relevant parts of the current editions of t...

Страница 6: ...6 Fig 1 General installation dimensions Surround Cut out Dimensions...

Страница 7: ...ht before installing in a timber frame building since the alterations required may nullify any NHBC cover relating to the property If in doubt guidance should be requested from your local authority pl...

Страница 8: ...ling 2 11 The appliance must not be installed in any room which contains a bath or shower or where steam is regularly present 2 12 An extractor fan may only be used in the same room as this appliance...

Страница 9: ...brick windows etc 300mm B Below gutters soil pipes or drain pipes 75mm C Below eaves 200mm D Below balconies or car port roof 200mm E From a vertical drain pipe or soil pipe 75mm F From an internal or...

Страница 10: ...nction box with cable clip earth lead sleeve fixings 1 Fire front casting 1 Strip gasket sealing tape For surround insulation 1 Bottom front cover casting 6 Wood screws plugs 2 Stainless steel screws...

Страница 11: ...le tip If there is no spark or incorrect tracking check the spark gap between the electrode wire and thermocouple tip see figure 5 If the spark gap is correct check the ignition wiring 4 3 Remove the...

Страница 12: ...he unit slightly forward 3 Detach the control unit cover by removing one screw See figure 10 4 Remove the cable by releasing the cable clamp and detaching the leads from the terminal block and earth c...

Страница 13: ...ked positions using a no 10 drill and plug 6 6 For duct connection from the right side 6 6 1 Remove the flue aperture cover and gasket and fit them to the left side see figure 11 Be careful not to dam...

Страница 14: ...quired to keep the gap clear of the wall on which the appliance is mounted see section 2 5 1 Drill a 5in 127mm dia hole The interior surface of the wall where the hole is exposed must be finished with...

Страница 15: ...in the wall and if applicable the fan box in the recess Push the box in so that the fixing brackets are against the wall and mark the screw fixing positions on the wall 7 5 Remove the fan box Drill t...

Страница 16: ...butted together even when covered by the elbow front covers Small children could touch the hot ducting if there are any gaps between the top horizontal flanges or bottom angled flanges of the backing...

Страница 17: ...catch in the cable clip slots in the brackets 8 7 Fix the backing plates to the wall The plastic spacing washers must be fitted between the backing plates and the wall Fit using the wood screws provi...

Страница 18: ...urround where it passes through the aperture in surround side Wrap the insulating gasket round the duct and secure with the sealing tape supplied as shown in figure 28 8 14 For horizontal duct install...

Страница 19: ...19 8 18 Do not block the gap between the top horizontal flange of the duct backing plates and the top rear edge of the front covers see figure 30 Figure 30...

Страница 20: ...ld be heard to increase to boost speed within approximately two seconds iii Remove the hand The fan should revert to normal speed after approximately three seconds 9 6 The unit includes a blocked flue...

Страница 21: ...holes in the shield with those at the sides of the end plate Secure with the two screws previously removed see figure 33 10 3 Fit the terminal guard see figure 34 Secure the guard at the bottom and a...

Страница 22: ...n the on switch Within two seconds the Fan motor should start and the indicator light should go out 11 5 4 Release the on switch The fan should continue to run 11 5 5 Depress the control knob and turn...

Страница 23: ...ting a pressure gauge at the test point The test point is on the pipe situated below the bottom right corner of the burner unit See figure 35 Check the pressure with the fan on the appliance alight an...

Страница 24: ...Left side R Right side Place the side walls against the sides of the fire box and in the recesses at the sides of the base coals The markings L R should be at the back bottom corners and facing to th...

Страница 25: ...control knob depressed for approximately ten seconds to allow the thermocouple probe to warm up and then release it If the pilot does not remain alight ensure that the pilot orifice is clear 13 1 6Wh...

Страница 26: ...indows that open to the outside of the building closed Recheck for spillage as above If the smoke is drawn into the appliance continue with the installation If the test is not satisfactory Disconnect...

Страница 27: ...the users guide Mention that in windy weather or when the mains voltage is low a slight click may be heard due to the fan control system switching between its normal and boost speeds Advise that if t...

Страница 28: ...ve the plaque clamping strips by detaching 6 screws 15 1 3 Remove the plaques and the combination gasket between and under the plaques If necessary remove the gauze and the gasket beneath it 15 1 4 If...

Страница 29: ...15 3 5 Disconnect the electrode lead from tab underneath the electrode 15 3 6 Undo the thermocouple nut at the gas tap 15 3 7 Disconnect the pilot pipe from the pilot unit elbow 15 3 8 Remove the firs...

Страница 30: ...e the gas tap solenoid unit as sections 15 5 1 to 15 5 12 15 6 2 Make sure that the tap is in the off position 15 6 3 Remove the circlip holding the piezo unit to the tap Remove the piezo unit 15 6 4...

Страница 31: ...witch see figure 53 15 10 5 Disconnect the three leads Yellow orange white from the air pressure switch 15 10 6 Disconnect the two leads Brown blue from the mains cable connection block 15 10 7 Replac...

Страница 32: ...e weather shield and flue box end plate by removing two screws see figure 55 15 12 3Disconnect the wiring loom connector inside the top right of the flue box see figure 56 15 12 4Slide the fan out of...

Страница 33: ...Control knob 1 545979 G Pilot unit For Natural Gas Appliances 1 540979 Pilot unit For Propane Appliances 544929 H Solenoid valve 1 559719 J Burner plaque gasket set 1 569439 K On switch 1 559729 L Off...

Страница 34: ...ds Valor is a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation Valor is a Corgi registered company All our ga...

Отзывы: