![Valor RetroFire RF24JDN Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/valor/retrofire-rf24jdn/retrofire-rf24jdn_installation-manual_851901010.webp)
10
Co-Linear with RA24CL
Overview
Rear view
Flashing
2 x 3”
liners
19-1/8”
3” min.
bend radius
2 x 3”
liners
40’
max
8’
min
RA24CL
co-linear
vent plate
RF24JD
insert
engine
Approved co-linear
termination or approved
co-linear adapter
and approved
co-axial
termination
Co-linear installation into existing F/P
RF24JD with RA24CL—Co-Linear Vent Plate
RF24JDN/P appliance
supplied without vent plate
RA24CL (3” x 3”)
Co-Linear Vent Plate with
AutoFire (supplied separately)
Co-Linear Vent Plate RA24CL
Sidewall co-linear installation into existing F/P using 720SWK—(see
installation instructions supplied with 720SWK)
Min. 3’-0”
*Max. 5’-0”
*Between 3’ and 5’ fully open restrictors.
Beyond 5’-0”, the sidewall terminal may be
used but leave restrictors opened at mid-point
as supplied.
720SWK
Terminal
3” Liners
3” min.
Bend
Radius
RF24JD with 720SWK—Sidewall Kit
10”
10”
3” Inlet & Exhaust
Collars
7-5/8” dia.
collar
720SWK—Sidewall terminal—with RA24CL ONLY
Front
Rear
12”
12”
8-1/2”
3”
intake
3”
exhaust
559CLT Roof te
559FSK Flashing