Valor Retrofire RF24IDN Скачать руководство пользователя страница 29

29

Parts

KEY

DESCRIPTION

PART 

NUMBER

1

Firebox Assembly

400634AH

2

Restrictor (2)

400767

3

Convection Baf

fl

 e

4000744

4

Fret Support LH

4002837BY

5

Wing Nut (2)

4000741

6

Leg LH

4000662

7

Leveling Bolt (2)

4000242

8a

Log Support NG

4000621

8b

Log Support LPG

4001456

9

Leg RH

4000663

10

Fret Support RH

4002836BY

11

Thumbscrew # 10-32x1/2” (4)

4000753

12a

Burner Tray Assy DV, NG

4000635

12b

Burner Tray Assy DV, LPG

4000653

13

Airshutter

4000657

14a

Injector Elbow NG 82-580

720A580

14b

Injector Elbow LP 92-260

9730007

15

Valve Tray, DV

4000714

16

Gasket Rear

4000642

17

Gasket LH Side

4000643

18

Gasket Front

4000641

19

Gasket RH Side

4000644

20

Burner Support

4000579

21

Burner

4000599

22

Shutter Slider

4000759

23

Front Log Bracket

4000739

24

Olive 8mm

519779

25

Olive Nut

523389

26

Pipe Valve to main Burner (incl. 
olive & nuts)

4000600

27

Tube Nut

523389

28

Valve Mount

4000141

29a

190 Series Pilot Assy NG

4000727

29b

190 Series Pilot Assy LPG

4000728

30

Electrode Nut

720A200

31

Pilot Gasket

4000715

32

Pilot Bracket 190 Series

4000729

Threaded Plug Pilot Bracket

4000726

33

Thermocouple

4000061

34a

NG Pilot Injector #51

4000735

34b

LPG Pilot Injector #30

4000736

KEY

DESCRIPTION

PART 

NUMBER

35

2-Flame Pilot Hood

4000730

36

Electrode

720A543

37

Pilot Tube

4000732

38

Thermocurrent Interruptor

4001037

39

GV60 Valve

4000873

40

Servo Motor

4001190

41

Switch with Cable

4001036

42

Cable Interrupter/Receiver

4001035

43

Ignition Cable

4001039

43a

Ignition Cable Insulation Sleeve

4002244

44

Receiver

4001911

45

Handset

4001910

46

Wiring Harness

4001187

47

Handset Wall Holder

9000008

48

Window Assy

4002860

49

Bottom Cover

4002835BY

50a

Log Set, Retro

fi

 re NG

4000603

50b

Log Set Retro

fi

 re LPG

4000603P

51a

Rear Log NG

4000688

51b

Rear Log LPG

4000688P

52

RH Log

4000691

53

Centre Log

4000692

54

Front Log

4000689

55

LH Log

4000690

56

Switch Bracket

4001070

Содержание Retrofire RF24IDN

Страница 1: ...eating appliance It must not be used for any other purposes such as drying clothes etc This appliance is suitable for installation in a bedroom or bed sitting room Manufactured by MILES INDUSTRIES LTD...

Страница 2: ...dealer immediately Do not try to repair the unit as you may cause an injury or damage the fireplace The information contained in this installation manual is believed to be correct at the time of prin...

Страница 3: ...stallation 13 Ceramic Fuel Bed Installation 16 Window Refitting and Checking 17 Remote Control Initial Set up 17 Operation Check and Aeration Adjustment 18 Optional Cast Iron Fret Installation 18 Opti...

Страница 4: ...peration Due to the high temperature the appliance should be LOCATED out of traffic areas and away from furniture and draperies Clothing or flammable material SHOULD NOT BE PLACED on or near the appli...

Страница 5: ...Ratings High Altitude Installations Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4 500 feet 1 370 m above sea level For elevations above 4 500 feet 1...

Страница 6: ...mbination of all the minimum dimensions shown although possible may prove to be difficult installations 24 1 2 8 25 1 2 27 10 11 RA24TB Fret Black 1225VFB Ventana Fret Black RA24CV Fret Vintage Iron R...

Страница 7: ...h inlet and exhaust liners must be run continuously from appliance to roof termination Where possible avoid joints in flex pipe If joints are required use only connectors approved by the manufacturer...

Страница 8: ...r drip edge to be formed on site Seal flashing to top of chimney using sealant not supplied Fasten terminal to flashing using sheet metal screws as shown Existing Round Factory Built Chimneys The 559C...

Страница 9: ...within 10 feet does not therefore apply Clearances for Vent Terminal Overhang should not extend beyond vent if within 48 of termination cap Horizontal overhang Vertical wall Min 24 unvented soffit Mi...

Страница 10: ...s allow for some vertical adjustment of the cast iron fret should the fret need to sit on top of the curb otherwise the fret will need to be eliminated or adequate room provided behind the curb Gas Li...

Страница 11: ...sting of that system at test pressures in excess of psig 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure te...

Страница 12: ...eplace cavity will affect the method of installation Smaller fireplaces particularly factory built zero clearance fireplaces will require the RF24 firebox to be disassembled then reassembled inside th...

Страница 13: ...ox on hearth Option 2 Connect liners in fireplace Support Legs Reinstallation if removed With the firebox recessed behind the smoke curtain of the existing fireplace raise the firebox and place the in...

Страница 14: ...k Remove Top Baffle 2 screws to provide space for a screwdriver Remove Top Baffle optional Leveling the firebox in the hearth The backside of each support leg has a leveling bolt If necessary adjust t...

Страница 15: ...top convection baffle with the threaded studs pointing downwards into the slots at the top of the firebox Slide the convection baffle as far forward as possible angled down if possible to force the a...

Страница 16: ...Front Log locating pins L H Log Locating Pins Place Middle Cross Log Across Gap in Front Log Place R H Cross Log Onto Locating Pins Place L H Cross Log Onto Locating Pins 5 4 3 1 2 Ceramic Log Set Ins...

Страница 17: ...indow Moves Freely After Reinstallation Spring Loaded Fastening Studs 2 1 4 Turn The receiver and the handset of the remote control system must be initially synchronized before the first use 1 Insert...

Страница 18: ...king the fuel effects glow less Too little aeration may result in black carbon forming and dropping into the firebox Air Shutter in Open Position Air Shutter in Closed Position Air Shutter Air Shutter...

Страница 19: ...nd causes dust lint etc to cling to the glass surface Initially paint while curing may deposit a slight film on the glass We therefore recommend that during the first few weeks of use the glass be cle...

Страница 20: ...e valve and it is retained to the firebox by a Velcro tab Grab the receiver and pull it out from its location 2 Slide and remove the receiver cover 3 Replace the 4 AA alkaline batteries 4 Replace the...

Страница 21: ...r turns automatically to maximum flame height 1 Make sure that the MAN knob on the valve is in ON position 2 Make sure that the switch on the valve is in the I position 3 Press and hold the OFF and la...

Страница 22: ...ressing either the or buttons Mode Sun Moon TEMP Daytime temperature setting Nighttime temperature setting TIMER Start time setting Stop time setting Flame Height The flame height can be adjusted in t...

Страница 23: ...ore you get up P1 start time and to turn off when you leave for the day P1 stop time Then you can set your fireplace to turn on again at the end of the day P2 start time and to turn off when you go to...

Страница 24: ...interrupted CAUTION DO NOT USE a screwdriver or other metallic object to remove the batteries from the battery box or the handset This could cause a short circuit Options Appliance RF24IDN Natural Gas...

Страница 25: ...QHDU WKH RRr If you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 3 AUTOMA7 1 7 21 J RFDWH WKH SLORW J LQVLGH RI UHER DW HIW DQG VLG...

Страница 26: ...26 Wiring Diagram Optional Wall Switch Kit 1265WSK Connector Red Yellow GV60 Wiring Diagram...

Страница 27: ...ex Connector 46DVA ADF Co axial to Co linear Adapter 46DVA GCL TM 4CAA 556CLA Co linear to Co axial Adapter 46DVA GK TM 4CTA Aluminum Flexible Liner 3 diameter 2280 Series 3 ACFL NOTE 2 ply liner appr...

Страница 28: ...n for air from other household equipment or appliances iii Damage due to chemicals dampness condensation or sulphur in the fuel supply lines which exceeds industry standards i This warranty does not c...

Страница 29: ...00 27 Tube Nut 523389 28 Valve Mount 4000141 29a 190 Series Pilot Assy NG 4000727 29b 190 Series Pilot Assy LPG 4000728 30 Electrode Nut 720A200 31 Pilot Gasket 4000715 32 Pilot Bracket 190 Series 400...

Страница 30: ...Parts 1 2 3 5 6 7 9 12a 12b 13 15 16 17 18 19 20 21 22 23 24 25 26 27 28 30 31 32 33 35 36 37 43 43a 46 47 52 53 54 55 29a 29b 34a 34b 14a 14b 50a 50b 51a 51b 8a 8b 4 10 11 48 49 40 38 56 41 42 39 44...

Страница 31: ...G natural gas LPG propane Serial No Fret code description e g RA24TB Traditional Black Fret Purchase date mm dd yyyy Home Owner Name Address City Province State Postal Code Zip Phone Email Address Sto...

Страница 32: ...Product Postage needed Were you given all documentation and manuals for your product YES NO Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC V7H 3B1 Canada Fold here Online Warranty...

Отзывы: