![Valor Retrofire RF24IDN Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/valor/retrofire-rf24idn/retrofire-rf24idn_installation-and-owners-manual_3827455019.webp)
19
Optional Bottom Cover Installation
Owner’s Information
Please read the
Safety and Warning
Information section at
the beginning of this
manual.
Operating Your Fire
For your safety, this appliance is
fi
tted with a
fl
ame
supervision device which will shut-off the gas supply
if, for any reason, the pilot
fl
ame goes out. This device
incorporates a
fi
xed probe, which senses the heat
from the pilot
fl
ame. If the probe is cool, the device will
prevent any gas
fl
ow unless the burner control knob is
kept pushed in at the PILOT position. See full lighting
instructions on page 25 of this manual.
Cleaning
It will be necessary to clean the glass periodically.
Check that Window
Moves Freely After
Reinstallation
Spring Loaded
Fastening Studs (2)
1/4 Turn
Warranty
Card at the
back of this
manual.
WARNING
DO NOT TOUCH THE GLASS WHILE IT IS HOT!
DO NOT TOUCH THE GLASS WHILE IT IS HOT!
Let the
fi
replace cool
fi
rst before cleaning it.
Let the
fi
replace cool
fi
rst before cleaning it.
CAUTION
Your
fi
replace becomes very hot when operating.
Your
fi
replace becomes very hot when operating.
Avoid placing decorating objects sensitive to heat
Avoid placing decorating objects sensitive to heat
within 36 inches (0.9 m) around it.
within 36 inches (0.9 m) around it.
Do not put
furniture or other objects
in this space in front of
the fireplace:
36” (0.9 m)
Fireplace
Hearth
Performance of LPG appliances may be affected by
the quality of commercial gas supplied in your area.
During startup, condensation, which is normal, forms
on the inside of the glass and causes dust, lint etc. to
cling to the glass surface. Initially paint, while curing,
may deposit a slight
fi
lm on the glass. We therefore
recommend that, during the
fi
rst few weeks of use,
the glass be cleaned two or three times with non-
abrasive common household cleaners and warm
water. Ammonia based cleaners should not be used.
Subsequently, the glass should be cleaned two or three
times a season depending on the circumstances.
Do not clean the glass while it is hot.
Always securely replace the window before lighting.
If broken, the glass pane may only be replaced
as a complete window unit as supplied by the
manufacturer.
It is necessary to remove the cast iron fret and
brackets or the bottom cover before removing the
window—see previous installation sections.
The window
can be removed
for cleaning by
rotating the two
fastening studs at
the bottom corners
90 degrees to
release, and
swinging the
bottom of the
window unit
outwards to
unhook the top edge.
After re
fi
tting the window, apply light hand pressure against
the window frame sides to bed-in the window seal.
Hook the upper
fl
ange of the bottom
cover onto the window bolts.
Important:
When the bottom cover is used instead of a fret,
a space is required in front of the window to allow the window
to move and relieve during a hard start.
It is therefore very
important to ensure that an area of 3/4 inch (19 mm) in front
of the window is kept clear at all times.
Hook the top
flange of the
bottom cover
to the window
retaining pins
Top
Front
Rear
Top flange
Bottom flange
(bends here)
Bottom
(end plates longer
than front plate
at bottom)
Rear View
Side View
Top
Bottom
DO NOT use
this hole
An area of 3/4 inch (19 mm) in front of the
window MUST be kept clear at all times!