Valor Retrofire RF24IDN Скачать руководство пользователя страница 1

Patents Pending

© 2011 Miles Industries Ltd. All rights reserved.

Model RF24IDN/IDP

Direct Vent Fireplace Insert

Installation and Owner’s Manual

WARNING: If the information in these 
instructions is not followed exactly, a fi re 
or explosion may result causing property 
damage, personal injury or loss of life.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light the appliance.
• Do not touch any electrical switch; do not 

use any phone in your building.

• Immediately call your gas supplier from 

a neighbor’s phone. Follow the gas 
supplier’s instructions.

• If you cannot reach your gas supplier, call 

the fi re department.

This appliance is only for use with the type 
of gas indicated on the rating plate. This 
appliance is not convertible for use with 
other gases, unless a certifi ed kit is used.

This appliance is a domestic room-heating 
appliance. It must not be used for any other 
purposes such as drying clothes, etc.

This appliance is suitable for installation in a 
bedroom or bed sitting room.

Manufactured by

MILES INDUSTRIES LTD., 

British Columbia, Canada

www.valor

fi

 replaces.com

Do not store or use gasoline or other 
fl ammable vapors and liquids in the vicinity 
of this or any other appliance.

Installation and service must be performed 
by a qualifi ed installer, service agency or the 
gas supplier.

This appliance may be installed in an 
after-market permanently located, 
manufactured (mobile) home where not 
prohibited by local codes.

INSTALLER: Leave this manual 
with the appliance.
CONSUMER: Retain this manual 
for future reference.

Please read this manual BEFORE installing 
and operating this appliance.

Massachusetts: The piping and fi nal 
gas connection must be performed by a 
licensed plumber or gas fi tter in the State of 
Massachusetts.

HOT GLASS

 WILL 

CAUSE BURNS.

DO NOT TOUCH

 GLASS 

UNTIL COOLED.

NEVER

 ALLOW CHILDREN 

TO TOUCH GLASS.

4002315-06

Содержание Retrofire RF24IDN

Страница 1: ...eating appliance It must not be used for any other purposes such as drying clothes etc This appliance is suitable for installation in a bedroom or bed sitting room Manufactured by MILES INDUSTRIES LTD...

Страница 2: ...dealer immediately Do not try to repair the unit as you may cause an injury or damage the fireplace The information contained in this installation manual is believed to be correct at the time of prin...

Страница 3: ...stallation 13 Ceramic Fuel Bed Installation 16 Window Refitting and Checking 17 Remote Control Initial Set up 17 Operation Check and Aeration Adjustment 18 Optional Cast Iron Fret Installation 18 Opti...

Страница 4: ...peration Due to the high temperature the appliance should be LOCATED out of traffic areas and away from furniture and draperies Clothing or flammable material SHOULD NOT BE PLACED on or near the appli...

Страница 5: ...Ratings High Altitude Installations Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4 500 feet 1 370 m above sea level For elevations above 4 500 feet 1...

Страница 6: ...mbination of all the minimum dimensions shown although possible may prove to be difficult installations 24 1 2 8 25 1 2 27 10 11 RA24TB Fret Black 1225VFB Ventana Fret Black RA24CV Fret Vintage Iron R...

Страница 7: ...h inlet and exhaust liners must be run continuously from appliance to roof termination Where possible avoid joints in flex pipe If joints are required use only connectors approved by the manufacturer...

Страница 8: ...r drip edge to be formed on site Seal flashing to top of chimney using sealant not supplied Fasten terminal to flashing using sheet metal screws as shown Existing Round Factory Built Chimneys The 559C...

Страница 9: ...within 10 feet does not therefore apply Clearances for Vent Terminal Overhang should not extend beyond vent if within 48 of termination cap Horizontal overhang Vertical wall Min 24 unvented soffit Mi...

Страница 10: ...s allow for some vertical adjustment of the cast iron fret should the fret need to sit on top of the curb otherwise the fret will need to be eliminated or adequate room provided behind the curb Gas Li...

Страница 11: ...sting of that system at test pressures in excess of psig 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure te...

Страница 12: ...eplace cavity will affect the method of installation Smaller fireplaces particularly factory built zero clearance fireplaces will require the RF24 firebox to be disassembled then reassembled inside th...

Страница 13: ...ox on hearth Option 2 Connect liners in fireplace Support Legs Reinstallation if removed With the firebox recessed behind the smoke curtain of the existing fireplace raise the firebox and place the in...

Страница 14: ...k Remove Top Baffle 2 screws to provide space for a screwdriver Remove Top Baffle optional Leveling the firebox in the hearth The backside of each support leg has a leveling bolt If necessary adjust t...

Страница 15: ...top convection baffle with the threaded studs pointing downwards into the slots at the top of the firebox Slide the convection baffle as far forward as possible angled down if possible to force the a...

Страница 16: ...Front Log locating pins L H Log Locating Pins Place Middle Cross Log Across Gap in Front Log Place R H Cross Log Onto Locating Pins Place L H Cross Log Onto Locating Pins 5 4 3 1 2 Ceramic Log Set Ins...

Страница 17: ...indow Moves Freely After Reinstallation Spring Loaded Fastening Studs 2 1 4 Turn The receiver and the handset of the remote control system must be initially synchronized before the first use 1 Insert...

Страница 18: ...king the fuel effects glow less Too little aeration may result in black carbon forming and dropping into the firebox Air Shutter in Open Position Air Shutter in Closed Position Air Shutter Air Shutter...

Страница 19: ...nd causes dust lint etc to cling to the glass surface Initially paint while curing may deposit a slight film on the glass We therefore recommend that during the first few weeks of use the glass be cle...

Страница 20: ...e valve and it is retained to the firebox by a Velcro tab Grab the receiver and pull it out from its location 2 Slide and remove the receiver cover 3 Replace the 4 AA alkaline batteries 4 Replace the...

Страница 21: ...r turns automatically to maximum flame height 1 Make sure that the MAN knob on the valve is in ON position 2 Make sure that the switch on the valve is in the I position 3 Press and hold the OFF and la...

Страница 22: ...ressing either the or buttons Mode Sun Moon TEMP Daytime temperature setting Nighttime temperature setting TIMER Start time setting Stop time setting Flame Height The flame height can be adjusted in t...

Страница 23: ...ore you get up P1 start time and to turn off when you leave for the day P1 stop time Then you can set your fireplace to turn on again at the end of the day P2 start time and to turn off when you go to...

Страница 24: ...interrupted CAUTION DO NOT USE a screwdriver or other metallic object to remove the batteries from the battery box or the handset This could cause a short circuit Options Appliance RF24IDN Natural Gas...

Страница 25: ...QHDU WKH RRr If you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 3 AUTOMA7 1 7 21 J RFDWH WKH SLORW J LQVLGH RI UHER DW HIW DQG VLG...

Страница 26: ...26 Wiring Diagram Optional Wall Switch Kit 1265WSK Connector Red Yellow GV60 Wiring Diagram...

Страница 27: ...ex Connector 46DVA ADF Co axial to Co linear Adapter 46DVA GCL TM 4CAA 556CLA Co linear to Co axial Adapter 46DVA GK TM 4CTA Aluminum Flexible Liner 3 diameter 2280 Series 3 ACFL NOTE 2 ply liner appr...

Страница 28: ...n for air from other household equipment or appliances iii Damage due to chemicals dampness condensation or sulphur in the fuel supply lines which exceeds industry standards i This warranty does not c...

Страница 29: ...00 27 Tube Nut 523389 28 Valve Mount 4000141 29a 190 Series Pilot Assy NG 4000727 29b 190 Series Pilot Assy LPG 4000728 30 Electrode Nut 720A200 31 Pilot Gasket 4000715 32 Pilot Bracket 190 Series 400...

Страница 30: ...Parts 1 2 3 5 6 7 9 12a 12b 13 15 16 17 18 19 20 21 22 23 24 25 26 27 28 30 31 32 33 35 36 37 43 43a 46 47 52 53 54 55 29a 29b 34a 34b 14a 14b 50a 50b 51a 51b 8a 8b 4 10 11 48 49 40 38 56 41 42 39 44...

Страница 31: ...G natural gas LPG propane Serial No Fret code description e g RA24TB Traditional Black Fret Purchase date mm dd yyyy Home Owner Name Address City Province State Postal Code Zip Phone Email Address Sto...

Страница 32: ...Product Postage needed Were you given all documentation and manuals for your product YES NO Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC V7H 3B1 Canada Fold here Online Warranty...