12
We recommend having your
fi
replace serviced before initial use, and at least once per year by a quali
fi
ed service
technician. Contact your dealer quoting the model serial number, if possible. It will be helpful if the
fi
replace’s
serial number can also be quoted. These numbers are on the information card (see page 7).
A list of replacement parts is included in your
fi
replace Installation Manual. When requesting spare parts please
quote the part number and description to ensure the correct part is ordered.
Annual Inspection
To ensure the optimal performance and safety of your
fi
replace, contact your dealer to have a quali
fi
ed
technician review and verify the list below at least once every year.
Safe Operation List:
to be performed by a quali
fi
ed technician only.
Inspect and operate the pressure relief mecha-
nism to verify relief mechanisms are free from
obstruction to operate. See
Cleaning your
fi
replace
on page 13
.
Clean glass window with a suitable
fi
replace
glass cleaner. Abrasive cleaners must not be
used. Be careful not to scratch the glass when
cleaning. See
Cleaning your
fi
replace
on page
13
.
Inspect the operation of the
fl
ame safety sys-
tem Pilot or Flame recti
fi
cation device.
Inspect and ensure the lighting of the main
burner occurs within 4 seconds of the main
gas valve opening. Visual inspection should
match that outlined in the appliance instruc-
tion manual. Inspect primary air openings for
blockage. See
Checking pilot and burner
fl
ames
on page 17
.
Inspect condition of vent and vent terminal for
sooting or obstruction and correct if present.
Vacuum and clean any excess debris in the
fi
rebox that is not supposed to be there.
Test and measure the
fl
ame failure response
time of the
fl
ame safety system. It must de-
energize the safety shut-o
ff
in less than
30 seconds.
Check all accessible gas-carrying tubes, con-
nections, pipes and other components for
leaks. See
Set up Gas Supply
section of the
fi
replace Installation Manual.
Annual service and maintenance
Caution
Label all wires prior to disconnection when
servicing controls. Wiring errors can cause
improper and dangerous operation.
Verify proper operation after servicing.
Содержание RetroFire RF24DJN
Страница 26: ...26 Notes...