 Pressure test the supply line for leaks.

The appliance and its individual shut-o

  valve must be 

disconnected from the gas supply piping system during 

any pressure testing of that system at test pressures in 

excess of 1/2 psig (3.5 kPa).
The appliance must be isolated from the gas supply 

piping system by closing its individual manual shut-o

  

valve during any pressure testing of the gas supply 

piping system at test pressures equal to or less than 

1/2 psig (3.5 kPa).
Failure to either disconnect or isolate the appliance 

during pressure testing may result in regulator or valve 

damages and void the warranty. Consult your dealer in 

case of damages.

Pressure Test Points

The minimum supply pressure is given in the section 

“Speci

fi

 cations” on page 6

.

All piping and connections must be tested for leaks 

after installation or servicing. All leaks must be 

corrected immediately.
When testing for leaks:

• Make sure that the appliance is turned o

 .

• Open the manual shut-o

  valve.

• Test for leaks by applying a liquid detergent or soap 

solution to all joints. Bubbles forming indicate a gas leak.

WARNING

Never use an open flame to check 

for leaks. Correct any leak detedted 

immediately.

Manifold 

Test 

Pressure

Valve Inlet 

Pressure

Manifold pressure 

adjustment screw 

located behind plastic 

mushroom cap.

Pressure Testing

Place the appliance in 

fi

 nal position

1.  Taking great care not to cut your hands on the sheet 

metal edges, place the appliance in its 

fi

 nal position  

in the framing. 

Make sure that the unit is at the right 

height with consideration to the height of the hearth or 

combustible 

fl

 ooring. 

2.  Remove carrying handles on both side.

Complete Installation of HeatShift Kit 

(required)

See 

“Appendix D - HeatShift System” on page 72

.

Installation

The pressure test tapping locations are shown in the 

fi

 gure below. An internal regulator within the valve 

controls the burner manifold pressure. 
The correct pressure range is shown in the table in 

section 

“Speci

fi

 cations” on page 6

The pressure check should be made with the burner 

alight and at its highest setting. See “Appendix A - 

Lighting Instructions Plate”

Gas Supply

Содержание LX2 CORNER

Страница 1: ...s If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Hot glass will cause burns Do no...

Страница 2: ...h Vancouver BC Canada V7H 3B1 T 604 984 3496 F 604 984 0246 valorfireplaces com This appliance may be installed in an after market permanently located manufactured mobile home where not prohibited by...

Страница 3: ...22 Restrictors 23 Wall Termination 24 Roof Termination 25 Preparation 26 Window Sill Window 26 Stando s Adapter 27 Installation 28 Electrical Wiring 28 Gas Supply 29 Remote Battery Wall Switch Kit 31...

Страница 4: ...ss of 200 F 93 C depending on elevation of hearth Be careful of touching these Tem perature of projection surfaces will be reduced when barrier screens are installed Some materials or items although s...

Страница 5: ...prohibited Fireplace Safety Intended use This appliance is designed and approved as a supple mental heater and provides the potential for most energy conservation when used while attended The use of...

Страница 6: ...36 000 Input Minimum Btu h 19 000 21 000 Manifold Pressure in w c 3 7 9 0 Minimum Supply Pressure in w c 5 11 Maximum Supply Pressure in w c 10 14 Main Burner Injector Marking DMS 32 DMS 49 Pilot Inj...

Страница 7: ...lective Glass Liners Reflective Glass End Panel 2200LML 2200LMP Limestone Liners Limestone End Panel HeatShift LDK1 Quad Plenum 48 LDK3 Double Plenum 14 2 with Grille LDK4 Quad Plenum 38 LDK7 Duct Ter...

Страница 8: ...Center of vent 17 17 mm 432 2 5 1 4 133 mm 11 1 4 1 mm 285 5 11 11 mm 279 9 20 508 mm 18 457 mm 11 1 2 292 mm 8 1 2 216 mm 2 51 mm 20 508 mm 18 457 mm 11 1 2 292 mm 6 1 2 165 mm 11 279 mm 7 178 mm 44...

Страница 9: ...nt sheet Also check that you have fuel bed packed separately liners packed separately Remote Battery Wall Switch Kit RBSWK HeatShift Kit mandatory Gas conversion kit if necessary Venting accessories E...

Страница 10: ...allowed below opening Combustible projections must otherwise be kept min 4 below opening HeatShift front outlet HeatShift sides outlet Remote Control Handset Wall Holder Wall Finish above openin ng Co...

Страница 11: ...s Fireplace opening 1 2 13 mm clearance to appliance Wood stud allowed at corners only Combustible wall finish allowed if framing out to flanged opening Combustible finishing materials up to 1 1 4 32...

Страница 12: ...ely 6 1 2 165 mm if using 8 vent 7 3 16 183 mm if using 6 5 8 vent from back surface of wall finish to front surface of appliance case w no vent offset 11 1 2 292 mm 17 432 mm 11 279 mm Min 16 1 2 419...

Страница 13: ...this dimension Alternatively substituting a 24 inch pipe length for the min 12 inch section will add 12 inches to this dimension as there is no additional pipe joint 5 1 4 133 mm Max 12 305 mm length...

Страница 14: ...ipe joint For example an additional 12 inch pipe section will add approximately 10 1 2 inches overall to this dimension 5 1 4 133 mm Max 24 610 mm length at this height 5 x 8 elbow directly on applian...

Страница 15: ...max Non combustible wall finish zone Max 1 1 4 32 mm thickness combustible wall finish allowed 20 508 mm min Combustible framing material Zero clearance standoffs 44 1 2 1130 mm min 11 1 4 285 mm 5 1...

Страница 16: ...l allowed on front wall Combustible material allowed on front wall Non combustible material on front wall Horizontal surfaces hearth overhang within this zone MUST be constructed of non combustible ma...

Страница 17: ...or not or plastered or unplastered shall be considered combustible materials Non combustible cement board The LX2 fireplace requires a 1 2 13 mm thick non combustible cement board to be used as a wall...

Страница 18: ...8 length when drying from a saturated condition Running the fireplace before final finishing will help drive out moisture Always pre drill screw holes through cement board and use screws with self mil...

Страница 19: ...Framing Vent in Combustible Walls Ceilings 6 5 8 and 8 pipes When penetrating through combustible walls and ceilings frame a minimum of 10 in x 10 in opening and ensure that the insulation is kept cle...

Страница 20: ...8 VENT ADAPTER SUPPLIED 5 x 8 VENT OUTLET PIPE LENGTH PIPE LENGTH CEILING FIRESTOP ATTIC FIRESTOP ATTIC INSULATION SHIELD FLASHING STORM COLLAR VERTICAL TERMINATION 90 ELBOW 90 ELBOW 90 ELBOW 90 ELBO...

Страница 21: ...Any combination of rise and run can be used as long as they are within the allowable limits shown on the chart below 5 A maximum of 4 x 90 degrees elbows or equiva lent 2 x 45 degrees 90 degrees can b...

Страница 22: ...ith roof termination is 6 feet 4 Any combination of rise and run can be used as long as they are within the allowable limits shown on the chart below 5 A maximum of 4 x 90 degrees elbows or equiva len...

Страница 23: ...ebox hidden above the top panel To access the restrictors remove the top panel 1 Remove 4 screws along the front or back of the panel 2 Release 4 screws along the other side of the panel It is not nec...

Страница 24: ...egulator assembly located within 15 feet 4 6bm below the terminal 36 90 I Clearance to service regulator vent outlet 36 90 J Clearance to non mechanical air supply inlet to the building or the combust...

Страница 25: ...8 12 1 5 Over 8 12 to 9 12 2 Over 9 12 to 10 12 2 5 Over 10 12 to 11 12 3 25 Over 11 12 to 12 12 4 Over 12 12 to 14 12 5 Overhang should not extend beyond vent if within 48 of termination cap Horizont...

Страница 26: ...mponents Remove Window Sill and Window Remove window sill Lift the sill up to free the magnets underneath then pull it straight out Remove the window 1 Hook the window handle to one of the spring load...

Страница 27: ...supporting that is it NOT supported by the engine Fit 6 5 8 x 4 Vent Adapter if required This unit is supplied with a 5 x 8 vent outlet which can be field converted to a 4 x 6 5 8 vent outlet by insta...

Страница 28: ...window It is hidden under the valve shield The v module is powered by a three prong plug plugged into a receptacle inside the appliance case at the rear on the left hand side RBWSK power connector RB...

Страница 29: ...nce The unit is supplied with a stainless steel flex line to allow the appliance to be disconnected for service An individual shut o valve supplied is required on the supply line ahead of the flex con...

Страница 30: ...nual shut o valve Test for leaks by applying a liquid detergent or soap solution to all joints Bubbles forming indicate a gas leak WARNING Never use an open flame to check for leaks Correct any leak d...

Страница 31: ...t of the appliance 2 Pull out the receiver from its location to connect the wiring harness power connector to receiver s jack 3 Connect the harness white connector to the auxil lary 5 pin junction on...

Страница 32: ...to the box us ing 4 screws provided 11 Feed the cable tie through the 2 side slots of the battery cover assembly 12 Position the battery holder to the rear face and secure together with a cable tie No...

Страница 33: ...ner s network See the literature that accompanies the WiFi module kit for instructions to install and set up See also 107 on page 92 Note The homeowner will either need to be present for installation...

Страница 34: ...panels however they don t fit into each other They sit beside each other Installation 1 Unpack the liner panels carefully 2 Remove the rear media tray 3 screws Ceramic liner panel sections top view 3...

Страница 35: ...the 3 panel supports against the top of each section and tighten the screw 11 Two brick retainers and three glass retainers are supplied with the panels They are used to hold the bottom of the rear pa...

Страница 36: ...ers Carefully unpack the kit as the logs are fragile Installation Fuel Beds Installation 1 Place log L2 with pin inserted as shown 2 Place log L1 from the left end of L2 and across the burner to rest...

Страница 37: ...ray as shown 6 Place log L6 from the top of L5 onto the front of the media tray as shown L5 L2 L12 L4 L2 L12 L5 L5 L4 L6 7 Remove and discard the pin from log L8 8 Place log L8 across the burner at th...

Страница 38: ...o the media tray and burner Do not pour embers as dust could block burner ports Place splinters among embers when complete WARNING CHOKING HAZARD Ensure that the fireplace area is clear of ember and s...

Страница 39: ...o not pour from the bag and do not pour too much to avoid blocking the burner ports NOTE Ensure the area within the pilot shield is clear of vermiculite Some vermiculite can be deposited into the pilo...

Страница 40: ...ner and behind as indicated This ver miculite will help keep the right rear log in position 5 Place the right rear log as indicated The small end of the log rests on the burner 1 3 4 inch from the fro...

Страница 41: ...installed 8 Vermiculite may be added outside the burner on the platform if desired around the logs 9 Place the rocks on the platform as shown below WARNING CHOKING HAZARD Ensure that the fireplace are...

Страница 42: ...layer to the level of the top edge of the flange around the burner Do not pour directly from the bag and do not pour too much to avoid blocking the burner ports NOTE Ensure the areas within the pilot...

Страница 43: ...the rear media tray and one for the front media tray Use the fourth bag to fill up gaps or edges of the burner NOTE Ensure the areas within the pilot shield and pilot safe zone are clear of fireglass...

Страница 44: ...es in the media tray Some logs straddle the burner make sure they rest over the smaller burner ports rather than the larger ones Large ports Do not place logs on Large ports Square hole use the square...

Страница 45: ...urner ports Log 6 straddles the burner do not cover the large burner ports Log 5 rests on rear notch of log 6 4 5 5 7 6 6 Log 7 rests on front notch of log 6 Log 9 straddles the burner do not cover th...

Страница 46: ...tail 11 10 Log 10 rests on the rear and the right edge of the media tray wrapping around the corner of the burner Note the right side of the log does NOT touch the window Log 11 rests on notch of log...

Страница 47: ...47 1 2 3 4 5 6 7 1 2 3 4 5 6 7 8 9 10 11 5 6 7 8 9 10 11 Logs installed full layout Fuel Beds Installation...

Страница 48: ...the embers NOTE Ensure the areas within the pilot shield and pilot safe zone are clear of embers or splinters Pilot shield Pilot safe zone IMPORTANT Approved for use only with the ce ramic embers and...

Страница 49: ...d and in pilot safe zone are clear of shale Do not put rocks on the pilot shield 2 Place rocks around the shale bed as indicated These rocks will be used to support the twigs The rocks used is not imp...

Страница 50: ...ded with your Valor fire place The use of any other products may void your fireplace warranty WARNING CHOKING HAZARD Ensure that the fireplace area is clear of shale pieces as these could be ingested...

Страница 51: ...See Window Sill Window on page 26 for details on removing the windows from the fireplace Change Bulbs Wear gloves when changing these bulbs Most manufacturers recommend never touching them as oil from...

Страница 52: ...the window pane 3 Insert the window behind the appliance s front panel and lower it into its bottom rail 4 Push the top of the window pane against the fire box Ensure it is centered on the firebox so...

Страница 53: ...cing or serious bodily injury and or damage to the fireplace may result To ensure safe operation Double check that the bottom of each window frame is correctly installed in the bottom support railing...

Страница 54: ...eld to the right and locate the receiver Detach it from the Velcro and pull it out 3 Locate the Reset button on the top side of the re ceiver 4 With a thin object press and hold the receiver s RESET b...

Страница 55: ...re provided with the kit Cover the screws with the included caps to finish the mounting Once mounted the holder is magnetic simply place the remote gently into the holder IMPORTANT The location of the...

Страница 56: ...picture may be improved by adjusting the aeration The need for adjustment should be determined only by operating the appliance with the fuel bed liners and window installed and evaluating the flame p...

Страница 57: ...Screen 1 Place the side screen on the window sill of the appli ance opening magnets inboard against plate flange Push top against top plate flange 2 Place the front screen magnets inboard against the...

Страница 58: ...ional LIGHT POWER V Module 120V Low voltage AC Power Lights MAN Knob Combination Control Valve Main Valve Knob PANEL red yellow Receiver Antenna RESET Button RBWSK Connector Battery Holder Battery Pow...

Страница 59: ...3 LJK LQG R D LDO 9 9 9 9 70 697 69 9 WHQGHG R D LDO 9 9 9 9 6QRUNHO 5LVH 7 67 70 67 6 6QRUNHO 5LVH 7 67 70 67 6 GMXVWDEOH 3LSH HQJWK DQG 3LSH WHQVLRQV DOYDQL HG RU ODFN 9 9 WR 7 RU WR WR 7 DOYDQL HG...

Страница 60: ...ROODU 9 6 9 6 7 6 70 6 69 6 HFRUDWLYH 3ODWH 9 9 7 6 70 75 70 73 69 3 3 DWKHGUDO HLOLQJ 6XSSRUW 9 6 9 6 7 6 70 66 56 7 HLOLQJ LUHVWRS ORRU 6XSSRUW 9 6 9 6 7 6 70 7 6 70 6 69 63 69 6 WWLF 5DGLDWLRQ 6KL...

Страница 61: ...xt adjacent floor level b In the event that the requirements of this subdivision can not be met at the time of completion of installation the owner shall have a period of thirty 30 days to comply with...

Страница 62: ...side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases but identifies special venting systems the following requirements shall be satisfied by the man...

Страница 63: ...IRU JDV LQFOXGLQJ QHDU WKH RRU I RX VPHOO JDV 6723 ROORZ LQ WKH VDIHW LQIRUPDWLRQ DERYH RQ WKLV ODEHO I RX GRQ W VPHOO JDV JR WR WKH QH W VWHS 8720 7 1 7 21 0 1 NQRE LQ 21 SRVLWLRQ QVXUH ODPH GMXVWPHQ...

Страница 64: ...y Status Eco Mode F or C To Turn On Fire One Button lighting default Two Button lighting simultaneously Press and hold for 4 seconds until 8 short beeps and a blinking series of lines con rms the star...

Страница 65: ...untdown Timer AM AM To deactivate functions 1 Install batteries All icons are displayed and ashing 2 While the icons are ashing press the relevant func tion button and hold for 10 seconds 3 The functi...

Страница 66: ...ntdown Timer only works in Manual Thermostatic and Eco modes Maximum countdown time is 9 hours and 50 minutes Light Dimmer Operation On Press is displayed Light is on at preset level Off Press disappe...

Страница 67: ...WiFi the handset will display APP Manual Mode The on o status of the replace as well as ame height are manually controlled by the user PM ON OFF PM PM Thermostatic Mode On Press is displayed Preset t...

Страница 68: ...To con rm press ON ON Off Time Setting PROGRAM 1 1 1 OFF are displayed ALL is displayed brie y Hour ashes 2 To select hour press or 3 To con rm press 1 OFF are displayed ALL displayed brie y Minutes...

Страница 69: ...a short circuit Low Battery Receiver With low battery power in the battery holder the system shuts o the re completely This will not happen if the power is completely interrupted Seven Day Shut Off Th...

Страница 70: ...no pilot ame No gas supply Air in pilot supply line No spark Reversed polarity in thermocouple wiring Incorrect pilot ori ce if valve has been converted from LPG to NG or vice versa F07 Low battery s...

Страница 71: ...ss and hold large flame button to gradually increase flame height Press and hold small flame button to gradually decrease flame height The Wall Switch can be used to control your fireplace You can tur...

Страница 72: ...Flexible aluminum duct is acceptable provided it meets the UL 181 Class 1 requirements Note These instructions are to be used in conjunction with instructions regarding replace installation in this m...

Страница 73: ...rately 38 frame white 2 14 x 6 grilles included white 4 take off collars included 4 take off collars included 4 take off collars included LDK2 supplied separately 48 frame white Kits Contents 39 5 8 1...

Страница 74: ...eplace With LDK7 WARNING The plenum duct kits are approved for horizontal discharge ONLY The termination duct plates are approved for vertical upward discharge ONLY DO NOT install plenum or terminatio...

Страница 75: ...le or rigid 5 diameter UL 181 Class 1 Air Duct 4 use LDK6 kit or equivalent Min 2 1 2 clearance to ceiling Min 30 Max 12 0 6HH WDEOH IRU R VHWV LX2 33 1 4 LX2 5 1 4 LX2 17 LX2 11 Ceiling Min 1 clearan...

Страница 76: ...t or equivalent Min 2 1 2 opening required at ceiling Min 30 Max 12 0 6HH WDEOH IRU R VHWV Min 14 LX2 33 1 4 LX2 5 1 4 LX2 17 LX2 11 Ceiling Min 1 clearance to combustibles around pipe Note Discharge...

Страница 77: ...wable Horizontal Offset X offset for take off that s furthest away Ceiling LDK 1 LDK 3 or LDK 4 Min bend radius Top of fireplace Min 1 clearance to combustibles around pipes Support horizontal section...

Страница 78: ...mounting bracket and 1 2 standoff 3 1 2 standoff 3 5 8 7 7 8 11 1 2 Top View Front View Right Side View LDK 4 38 LDK 4 5 dia collars 4 C L 8 14 8 4 4 3 3 5 8 7 7 8 11 1 2 1 2 standoff Front View Top...

Страница 79: ...doff 8 11 1 2 1 2 wallboard 1 2 standoffs Front View Right Side View 1 2 standoff LDK 9 30 LDK 9 5 dia collars 4 C L 7 1 16 7 1 16 7 1 16 4 3 8 4 3 8 3 9 1 2 Front View Top View 2 6 9 1 2 6 4 1 2 wall...

Страница 80: ...7 4 1 2 9 3 4 9 3 4 4 1 2 19 1 2 2 1 2 13 1 2 16 19 1 2 9 3 4 9 3 4 Stand offs fold down for shipping Warning Label Stand offs Front View Top View Right Side View Perimeter of plates may be trimmed to...

Страница 81: ...4 LDK 3 LDK 3 15 4 5 LDK 1 13 LDK 4 11 UDPLQJ RQ HGJH Top of plenum VXSSRUW UDPLQJ RQ HGJH Min 1 below QLVKHG FHLOLQJ 8VH VWHHO VWXG IRU DSSOLDQFHV 8 C L LDK9 Minimum 31 4 LDK 9 Min 1 below QLVKHG FH...

Страница 82: ...dictated by LDK plenum when installing across corners LX2 models using 8 venting PD UHTXLUH D YHQW R VHW WR clear the plenum Min 1 2 clearance to combustibles at ends Use steel stud for LX2 appliances...

Страница 83: ...pipes Framing on edge 1 1 2 min clearance to combustibles top Ceiling Min 2 1 2 clearance to ceiling 1 2 1 2 min clearance to combustibles rear sides 1 min clearance to combustibles all around pipes 4...

Страница 84: ...s as necessary maintain 1 clearance to pipes Wall finish required to form plenum above duct termination plates LDK 7 Duct Termination Plates 2 for horizontal installation ONLY Continuous ceiling requi...

Страница 85: ...d off Non combustible zone above plates Perimeter of plates may be trimmed to suit installation Combustible framing allowed below plates 5 dia pipes maintain 1 clearance to combustible materials Front...

Страница 86: ...he collars and secure it with gear clamps provided DO NOT SPLICE DUCTS 6 Attach the top of the pipe sections to the plenum securing them with the gear clamps provided An upward slope must be maintaine...

Страница 87: ...s posi tions Support horizontal sections every 24 inches 7 Continue with the replace installation Description Part no LDK1 48 Quad Hot Air Plenum Kit 48 x 2 quad plenum 4005476 5 take off collars 4 40...

Страница 88: ...32 Gas orifice DMS 32 natural gas 4007000 32 Gas orifice DMS 49 propane gas 4007000 49 33 Pilot gaskets 2 4000715 34 Pilot stand extrusion 4006649 35 Air shutter 4006594 36 Air shutter arm 4006582 Des...

Страница 89: ...1714RSS 87 LH twig 4001827 88 LH twig short 2 4001827S 89 RH twig 2 4001828 90 Grey Rock S4 A 7 4002338 91 Dark Grey Rock S4 A 5 4002339 92 Grey Rock S4 B 5 4002340 93 Dark Grey Rock S4 B 8 4002341 94...

Страница 90: ...35 38 38 36 39 39 40 41 42 43 44 45 46 47 34 33 33 23 29 30 31 50 51 55a 55b 55c 55d 55e 55f 55g 55h 55i 55 48 49 108 1 2 3 4 2 5 3 20 3 7 6 8 9 10 11 12 13a 13b 14 16 15 2 17 2 18 19 21 14a 14b Appen...

Страница 91: ...63 64 60 70 68 69 67 8 71 4 62 66 62 62 84 85 83 82 81 80 79 100 90 87 88 89 91 92 93 86 94 95 96 99 98 97 7 8 5 2 2 5 2 2 1714RSS 1705DWK 2 2200DGM 2200FBP 2200RGP 2200LMP 2200DGS 57 58 58 61 3 59 2...

Страница 92: ...92 1700BLK 102 103 104 101 1700SWK 3 2 1 5 6 7 8 9 10 11 4 105 106 107 Appendix E Spare Parts...

Отзывы: