52
Open
Close
Set air shutter with
a screwdriver
Check Operation
Turn the
fi
replace
fl
ame up and down using the
remote control to con
fi
rm that the full range of
inputs is achieved—see the remote control operation
instructions in Appendix.
Set Aeration
(if necessary)
Light the
fi
re and allow the unit to warm up for 10–15
minutes to evaluate the
fl
ame picture. The burner is
equipped with an adjustable shutter to control primary
aeration. The shutter is factory-set to an aeration gap
which will give optimum performance for the vast
majority of installations.
Depending of fuel bed used, altitude and other
considerations, the
fl
ame picture may be improved by
adjusting the aeration. The need for adjustment should
be determined only by operating the appliance with the
fuel bed, liners and window installed and evaluating the
fl
ame picture after a 15-minute warm-up.
Increasing aeration
will cause the
fl
ames to appear
more transparent and blue showing more ceramic
e
ff
ects glow.
Decreasing aeration
will cause the
fl
ames to appear
more yellow or orange showing less ceramic e
ff
ects
glow.
Too little aeration may result in black carbon forming
and dropping into the
fi
rebox.
Air Shutte
r
To access the air shutter, remove the barrier screen and
the base plate. The air shutter lever is located in front
of the
fi
rebox behind the appliance front panel. Adjust
the shutter by using a screwdriver as a lever to slide the
shutter left or right.
Check Operation