13
*
This is the minimum vent height when using 6-5/8 inch venting. If calculating the vent height using
additional
vent lengths, subtract approximately 1-1/2 inch for each pipe joint. For example, an
additional
12-inch pipe
section will add approximately 10-1/2 inches overall to this dimension. Alternatively,
substituting
a 24-inch pipe
length for the min. 12-inch section will add 12 inches to this dimension as there is no additional pipe joint.
5-1/4”
(133 mm)
Max. 12“ (305 mm)
length at this height
Min. 12” (305 mm)
pipe section
5” x 8” to 6-5/8” x 4” adapter
(supplied)
6-5/8” x 4” pipes
Required min.
clearance to
combustibles
8-1/2”
(216 mm)
2”
(51 mm)
* M
in. 56-3/8”
(1432 mm) when using 12”
pipe sec
tion
11-1/2”
(292 mm)
17”
(432 mm)
11”
(279 mm)
Planning
Minimum Vertical Vent—6-5/8” Vent