2

Wiring diagram
and label

Fan Unit

Fan Mounting Plate

ThermalSwitch

Power cable

Considerations

We highly recommend installing this fan (blower) kit to 
the appliance before completing the installation of the 
appliance otherwise the gas line must be disconnected 
and the burner module removed from the fi rebox to 
gain access to the blower area.

If installing this fan after the fi replace installation has 
been completed, remove the following components 
using the fi replace installation manual provided with the 
fi replace for guidelines:

• 

Trim side doors, trim plinth, window, fuel bed, 
vermiculate base platform, middle platform supports 
(front and back).

• 

Disconnect the gas line from the appliance at the 
appliance valve.

NOTE: Electrical wiring must be already installed 
inside the appliance case to complete the fan 
installation.

Test the fan

It may be desireable to test the fan operation before 
reassembling the burner module and completeing the 
fi replace installation. 

To test the fan operation the thermal switch can 
be temporarily bypassed by connecting the power 
cord lead directly to the fan motor (see diagram). 

Unplug the power cord from the receptacle before 
bypassing the thermal switch.

 Confi rm fan operation 

and speed control (if used) with the thermal switch 
bypassed then reconnect thermal switch. 

Note:

 If desireable, the thermal switch may be 

left permanently bypassed and the fan controlled 
exclusively by the wall switch or speed control.

Fan Kits Components

The complete 1595CFK kit contains the following:

• 

Fan unit (motor and housing)

• 

Fan mounting plate

• 

Thermal switch

• 

Power cable

• 

Wiring diagram label

• 

Sheet metal screws (2)

Sheet metal 
screws (2)

Remove wire from 
switch and connect 
directly to motor for 
testing

Содержание LINEAR SERIES

Страница 1: ...supplied by electrician These instructions cover the installation of the fan unit only For instruc tions regarding how and where to locate the power outlet within the fireplace casing refer to instru...

Страница 2: ...lled inside the appliance case to complete the fan installation Test the fan It may be desireable to test the fan operation before reassembling the burner module and completeing the fireplace installa...

Страница 3: ...he appliance bottom panel Then remove the 10 screws around the perimeter of the burner module plate 4 Rotate the rear edge of the burner module upwards and remove the module plate from the firebox To...

Страница 4: ...e heater Apply label to base next to fan Receptacle in lower right corner of liner box 2 Line up the slotted holes in the fan mounting plate with the holes in the base of the liner box and fasten usin...

Страница 5: ...ransportation of defective parts or 3 incidental or consequential damages THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING THE WARRANTY OF MERCHANTABILITY OF F...

Страница 6: ...llume Quand le foyer s teint le ventilateur continue de fonctionner temporaire ment jusqu ce que l interrupteur thermique refroidisse Note Lorsque le foyer fonctionne en bas r gime il est possible que...

Страница 7: ...plateforme du milieu avant et arri re D branchez l alimentation de gaz de l appareil la soupape NOTE Le c blage lectrique doit tre d j install dans la caisse du foyer pour compl ter l installation du...

Страница 8: ...10 vis retenant la plaque du module du br leur la bo te de foyer 4 Pivotez le bord arri re du module vers le haut et tirez le hors de la bo te de foyer Pour installer le ventilateur 1 Ins rez le vent...

Страница 9: ...T POUR CE VENTILATEUR ET NE DEVRAIT TRE REMPLAC QU AVEC DES PI CES ORIGINALES FOURNIES PAR LE FABRICANT MOD LE 1595CFK VENTILATEUR DE CIRCULATION D 120 V CA 60 Hz MOINS DE 1 A FABRIQU PAR MILES INDUST...

Страница 10: ...T LES GARANTIES DE QUALIT MARCHANDE OU D UTILISATION DE L APPAREIL DES FINS PARTICULI RES AINSI QUE TOUTES AUTRES OBLIGATIONS OU RESPONSABILIT S MILES INDUSTRIES LITD N ASSUME NI N AUTORISE AUCUNE PER...

Отзывы: