background image

Model

 

780NG

780LPG

Gas

Natural Propane

Altitude (Ft.)*

0-4,500 feet*

Input Maximum (Btu/h)

30,000

28,000

Input Minimum (Btu/h)

6,500

14,500

Manifold Pressure (in w.c.)

4.0

10.5

Minimum Supply Pressure 

(in w.c.)

5.0

11.0

Maximum Supply Pressure 

(in w.c.)

10.0

14.0

Main Burner Injector Marking

850

300

Pilot Injector Marking

51

30

Min. Rate By-Pass Screw

125

125

Burner identi

fi

 cation

L

EGEND

 G4

4002613-03

©2012, Miles Industries Ltd.

Gas Conversion Kit

780NGK/NPK

Installation Instructions

This appliance is certi

fi

 ed for use from 0–4500 feet. For 

altitudes above 4500 feet, see local codes.

Kit Contents

1 Pilot injector
1 Burner
1 Main burner elbow injector
1 Set of conversion labels
1 Set of air shutter
1 Air baf

fl

 e for rear log support (LPG only)

4 Screws (for LPG air baf

fl

 e)

Tools Required

•  Wrenches, to disconnect gas line
•  Phillips (+) screwdriver, to remove burner module
•  Small (jewelers size) 

fl

 at blade screwdriver, to set 

pressure

• Small 

fl

 at blade screwdriver, to release pressure tap 

on valve

•  Nut driver 8 mm or 5/16”, to remove burner nuts
•  Needle nose pliers, to remove by-pass screw
•  Hex (Allen) wrench, 4 mm or 5/32”, to remove pilot 

injector

•  Manometer, to set pressure when regulator is integral 

with valve

Speci

fi

 cations

Use with with 

Valor Models 780 Heaters ONLY

WARNING

This conversion kit shall be installed by a 
quali

fi

 ed service agency in accordance with 

the manufacturer’s instructions and all appli-
cable codes and requirements of the authority 
having jurisdiction. If the information in these 
instructions is not followed exactly, a 

fi

 re, ex-

plosion or production of carbon monoxide may 
result causing property damage, personal in-
jury or loss of life. The quali

fi

 ed service agency 

is responsible for the proper installation of this 
kit. The installation is not proper and complete 
until the operation of the converted appliance 
is checked as speci

fi

 ed in the manufacturer’s 

instructions supplied with the kit.

Use this manual in conjunction with the instal-
lation manual supplied with the appliance.

Содержание Legend G4 Series

Страница 1: ...ver to set pressure Small flat blade screwdriver to release pressure tap on valve Nut driver 8 mm or 5 16 to remove burner nuts Needle nose pliers to remove by pass screw Hex Allen wrench 4 mm or 5 32...

Страница 2: ...brackets from the burner by removing 2 nuts using a 5 16 8 mm wrench 4 Transfer the burner support brackets to the new conversion burner securing them with the 2 nuts removed in step 3 Note do not ove...

Страница 3: ...ck tighten afterwards Pressure Test Tappings Front Face of Control Valve Pry off plastic cap Front Face of Control Valve Pressure adjustment screw behind plastic cap Increases pressure Decreases press...

Страница 4: ...plied with the appliance 1 Refit the ceramic panels first then the front brick support and the rear log support 3 screws 2 Reinstall the grate with logs only the fuel bed the window the front trim and...

Страница 5: ...la pression sur la soupape Nut driver 8 mm or 5 16 to remove burner nuts Pince bec effil pour enlever la vis d incice Cl hexagonale Allen de 4 mm ou 5 32 pour enlever l injecteur de la veilleuse Mano...

Страница 6: ...enlevant deux crous l aide d une cl de 5 16 8 mm 4 Installez les supports de br leur sur le br leur de conversion en r utilisant les deux crous enlev s l tape 3 Note Ne serrez pas trop les crous pour...

Страница 7: ...evez le manom tre et serrez la vis de v rification de pression V rifiez tous les raccords pour voir s il y a des fuites 7 Fixez l tiquette Cette commande a t convertie pr s de la soupape 8 R installez...

Страница 8: ...neaux de c ramique le support de briques avant et ensuite le support de b che arri re 3 vis 2 R installez le porte b ches avec b ches seulement les b ches ou pierres la fen tre la bordure et la porte...

Отзывы: