background image

2

Conversion Procedure

1. If 

the 

fi replace is already installed, remove the 

window, ceramic logs and brick liners.

2.  Disconnect the gas inlet pipe from the inlet elbow 

fi tting on the valve.

3.  Detach the rear log support by removing 4 screws 

as shown.

4.  Detach the burner module by removing 4 screws.

5.  Disconnect the burner 

elbow injector from the 
pipe, using a 11/16” (17 
mm) wrench.

6.  Remove the 2 

screws securing the 
burner brackets to 
the burner tray.

7.  Detach the two burner support brackets from the 

burner by removing two nuts, using a 5/16” (8 mm) 
wrench.

8.  Accessing pilot assembly from underside of 

module, disconnect the pilot pipe, using a 7/16” 
(11 mm) wrench.

9.  Remove the pilot injector. Replace with natural gas 

injector.

10. Replace main burner with natural gas burner 

assembly supplied and reassemble module.

Note - The pilot 
injector should be 
slipped onto the 
end of the pipe 
from the side. The 
pilot pipe, with 
injector attached, 
should be inserted 
into the assembly.

Отзывы: