2
Conversion Procedure
1. If
the
fi replace is already installed, remove the
window, ceramic logs and brick liners.
2. Disconnect the gas inlet pipe from the inlet elbow
fi tting on the valve.
3. Detach the rear log support by removing 4 screws
as shown.
4. Detach the burner module by removing 4 screws.
5. Disconnect the burner
elbow injector from the
pipe, using a 11/16” (17
mm) wrench.
6. Remove the 2
screws securing the
burner brackets to
the burner tray.
7. Detach the two burner support brackets from the
burner by removing two nuts, using a 5/16” (8 mm)
wrench.
8. Accessing pilot assembly from underside of
module, disconnect the pilot pipe, using a 7/16”
(11 mm) wrench.
9. Remove the pilot injector. Replace with natural gas
injector.
10. Replace main burner with natural gas burner
assembly supplied and reassemble module.
Note - The pilot
injector should be
slipped onto the
end of the pipe
from the side. The
pilot pipe, with
injector attached,
should be inserted
into the assembly.