background image

Code

Description

Part 

Number

1

Exhaust Slide Assembly

4001133

2

Exhaust Slide Gasket

4001662

3

Fan Closure Plate

4001136

4

Port Cover

4001820

5

Rock Support (739IR)

4001768

5

Log Support (739JL)

4004353

6

Side Bricks Anchors (2)

4001283

7

Top Mounting Bracket

4000136AZ

8

Side Mounting Brackets (2)

4000135AZ

9

Window Assembly

4001378

10

Burner Assembly NG

4001375S

Burner Assembly LPG

4001376S

11

Burner Rail NG

4001665

Burner Rail LPG

4001666

12

Injector Elbow (Main Burner) NG

4000738

Injector Elbow (Main Burner) LPG

9730007

13

Air Shutter Cover NG

4002346

13a

Air Shutter Slider NG

4002345

14

Flashback Shield LPG

3000371

14a

Air Shutter Slider LPG

320B293

15

Burner Baf

fl

 e

4001784

16

Burner Mounts (2)

4001678

17

Pilot Shield

4000144

18

Pilot Assembly NG

4000062S

Pilot Assembly LPG

4000063S

19

Pilot Bracket

720A542

20

Pilot Injector NG—No 35

4002511

Pilot Injector LPG—No 27

720A195

21

Hooked Olive for Pilot Injector

720A196

22

Olive Nut for Pilot Pipe

420K385

23

Electrode

720A543

24

Electrode Retaining Nut

720A200

25

Thermocouple

4000061

26

Pilot Gasket A

4000139

27

Pilot Mount

4000138

28

Pilot Gasket B

4000140

29

Burner Tray

4001676

30

Pipe—Valve to Main Burner (incl. 
olive & nuts)

4000065

31

Burner Plate Access Panel

4001680

32

Module Gasket—Rear

4000175

33

Module Gasket—Right

4000174

Spare Parts

Code

Description

Part 

Number

34

Module Gasket—Front

4000173

35

Module Gasket—Left

4000181

36

Olive Nut for Pilot Pipe

220K913

37

Pipe—Valve to Pilot

4001838

38

Thermal Switch Retainer

4001519

39

Valve Mounting Bracket

4000141

40

Switch Bracket

4001070

42

Thermocurrent Interruptor

4001037

44

Hot Glass Warning Plate

4003093

45a

GV60 Valve Assembly NG

4003097

45b

GV60 Valve Assembly LPG

4003110

47

Switch with Cable

4001036

48

Cable Interruptor

4001035

49

Ignition Cable 500 mm

4001039

49a

Ignition Cable Sleeve

4002244

50

Receiver G6R-R3AM-ZV (CP)

4001911

51

Handset G6R H3T5-ZV (BJ)

4001910

52

Wiring Harness

4001187

53

Handset Wall Holder

9000008

54

Rock Set Complete (739IR)

4001791

55

Rock No. 1 (739IR)

4001821

56

Rock No. 2 (739IR)

4001822

57

Rock No. 3 (739IR)

4001823

58

Rock No. 4 (739IR)

4001824

59

Rock No. 5 (739IR)

4001825

60

Rock No. 6 (739IR)

4001826

61

Rock Base (739IR)

4001792

62

LH Twig (739IR)

4001827

63

RH Twig (739IR)

4001828

64

Liner Set Complete
Fluted Liner Set Complete (739IR)

4001831

Brick Set Complete (739JL)

4001515

65

Rear Panel
Rear Fluted Panel (739IR)

4001814

Rear Brick Panel (739JL)

4001811

66

Left Panel
Left Fluted Panel (739IR)

4001812

Left Brick Panel (739JL)

4001809

67

Right Panel

36

OWNER’S 
INFORMATION

Содержание LEGEND 739JLN Logs

Страница 1: ...an ais sur demande This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used This appl...

Страница 2: ...30 Check Operation 31 Adjust Aeration if necessary 31 Install Front Trim and Barrier Screen 31 Install Handset Wall Holder 32 Wiring Diagram 33 Approved Venting Components 34 Warranty 35 Spare Parts 3...

Страница 3: ...BE PLACED on or near the appliance This unit MUST be used with a vent system as described in this installation manual NO OTHER vent system or components MAY BE USED This gas fireplace and vent assemb...

Страница 4: ...ace A physical barrier is strongly recommended if there are young children or at risk individuals in the house Install an approved after market safety gate to keep toddlers young children and other at...

Страница 5: ...r fireplace is fully tested during the production process for your safety and comfort Your unit has been professionally installed by Dealer Name ________________________________ Phone Number _________...

Страница 6: ...ot clean the glass while it is hot Always securely replace the window and the barrier screen before lighting If broken the glass pane may only be replaced as a complete window unit as supplied by the...

Страница 7: ...he battery life Should the batteries loose power the control may be operated by manually turning the control knob at the valve or by turning off the valve at the switch To replace the batteries in the...

Страница 8: ...ncrease or decrease the flame height see 1265WSK Wall Switch Kit NOTE The remote control in the AUTO mode will override the wall switch How to Turn Your Fireplace OFF including pilot Familiarize yours...

Страница 9: ...flame height NOTE Before using the remote control system for the first time the receiver and the handset must be synchronized See the section Remote Control Initial Set up on page 30 of this manual Se...

Страница 10: ...hour Press small flame button to set the minute Press OFF or simply wait to return to MAN mode Double click large flame button Flame automatically goes to high fire HI will be displayed Manual Mode Ma...

Страница 11: ...gramming SETTING THE DAYTIME TEMPERATURE SETTING THE NIGHTTIME SETBACK TEMPERA TURE Default Settings sun 23 C 74 F Default Settings moon OFF Press large flame button to increase Nighttime Setback Temp...

Страница 12: ...ashes Press large flame button to set the hour Press large flame button to set the hour Press small flame button to set the minutes Press small flame button to set the minutes SETTING P1 ON TIME SETTI...

Страница 13: ...batteries need to be replaced Replace with four 1 5 V alkaline batteries The remote control handset and receiver are program med to function together In case of a replacement of the handset or the rec...

Страница 14: ...f you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 3 AUTOMA7 1 7 21 J RFDWH WKH SLORW J LQVLGH RI UHER DW HIW DQG VLGH 21 2 VZLWFK L...

Страница 15: ...PA 70 or the Canadian Electrical Code CSA C22 1 High Altitude Installations Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4 500 feet 1 370 m above sea...

Страница 16: ...with Barrier Screen required sold separately Fret optional sold separately 2 x 3 approved flex chimney liners running full length WARNING HOT HEARTH FLOOR The hearth or floor in front of the fireplace...

Страница 17: ...rical inlet Optional Outer Trim or Surround sold separately X Y Dimensions Cavity Check that masonry step does not interfere with install dimensions or vent pipe If mantel is combustible see section C...

Страница 18: ...essed paper plant fibers plastics or any material capable of igniting and burning whether flame proofed or not plastered or un plastered Non combustible materials Material such as steel iron brick til...

Страница 19: ...rmination Venting Table Maximum vertical height 40 ft measured to bottom of termination Minimum vertical height 10 ft measured to bottom of termination Maximum horizontal run 4 ft measured center to c...

Страница 20: ...Check that you have everything 4 Clean cavity chimney ash dump and clean out 5 Install venting pipes 6 Attach conversion plate to existing fireplace 7 Install and test blower if used 8 Fit appliance i...

Страница 21: ...le of 1 5 inch 38 mm or less through the lower sides or bottom of the firebox The access hole must be plugged with non combustible insulation after the gas supply line has been installed See Dimension...

Страница 22: ...de in a safe place to avoid damage Install Fan if used If the 755CFK Circulating Fan Kit blower is to be installed we suggest that you do it now The fan cavity is accessible from the back of the fireb...

Страница 23: ...the firebox 3 Apply RTV sealant to the collars on the vent slider and fit the two liners ensuring that the exhaust liner is connected to the identified EXHAUST vent collar Secure with 4 tapping screw...

Страница 24: ...t pressures in excess of 1 2 psig 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its equipment shut off valve during any pressure testing of the gas supply piping...

Страница 25: ...firebox on the ledge at bottom 3 Rotate the anchor up and out of the way and slide the left hand side panel against the firebox side The panel should be parallel to the edge of the burner plate Rotate...

Страница 26: ...of the sheet metal support Note The rear log will appear slightly angled backward on the left side compared to the burner The space between the log and the burner is purposefully wider on the left th...

Страница 27: ...to hide the sheet metal work Do NOT put any coal into the pilot area Notch in rear log Pin in front right log 4 Place the front right log on the burner and slide it to the left against the front left...

Страница 28: ...rotating down to insert the front first behind the Front Support Lay the back of the ceramic platform against the rear ceramic panel again being careful not to scrape the ceramic panels Warning This p...

Страница 29: ...e to come up between the twig and the rock 7 Place the right twig across the second and third rocks from the right rest its end on the glass about 1 cm from the edge of the platform as shown Make sure...

Страница 30: ...lass and the frame as indicated Synchronize Remote Control The receiver and the handset of the remote control sys tem must be initially synchronized before the first use 1 Insert alkaline batteries in...

Страница 31: ...ed by adjusting the aeration The need for adjustment should be determined only by operating the appliance with the ceramic logs and window installed Increasing aeration open will cause the flames to a...

Страница 32: ...ll find a convenient location and use the hardware provided with the kit See the diagram below for required hardware and configurations Note that the holder can be installed at the base of a light swi...

Страница 33: ...Optional Wall Switch Kit 1265WSK Connector Red Yellow GV60 Wiring Diagram Wiring Diagram QUALIFIED INSTALLER 33...

Страница 34: ...ial Adapter 46DVA GK TM 4CTA 4DCAT33 Aluminum Flexible Liner 3 or 4 diameter NOTE 2 ply liner approved to CAN ULC S635 suitable for venting gas appliances As manufactured by Z Flex Flexmaster and othe...

Страница 35: ...other household equipment or appliances iii Damage due to chemicals dampness condensation or sulphur in the fuel supply lines which exceeds industry standards i This warranty does not cover glass log...

Страница 36: ...ain Burner incl olive nuts 4000065 31 Burner Plate Access Panel 4001680 32 Module Gasket Rear 4000175 33 Module Gasket Right 4000174 Spare Parts Code Description Part Number 34 Module Gasket Front 400...

Страница 37: ...69 Front Support Platform 739IR 4001835AH 70 Ceramic Platform 739IR 4001832 71 Log Set Complete 739JL 4003794 72 Rear Log 739JL 4003787 73 LH Top Log 739JL 4003788 74 RH Top Log 739JL 4003789 75 RH Ce...

Страница 38: ...9 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 42 45a 45b 14a NG LPG 13a 47 48 49 50 51 52 53 49a 71 72 73 74 75 76 77 78 44 55 56 57 58 59 60 61 54 62 63 66...

Страница 39: ...provided will be used for customer records only Online Warranty registration at www valorfireplaces com Cut out page fill information and mail to Miles Industries Ltd Fireplace Information Model Numbe...

Страница 40: ...hut Thank you for choosing a Valor Product Postage needed Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC V7H 3B1 Canada Fold here Online Warranty registration at www valorfireplace...

Отзывы: