Install Electrical Wiring (if required)
This section provides information to install the elec-
tric pre-wiring required for use with the optional
1595CFKV2 Circulating Fan Kit and/or the GV60WIFI Kit.
All wiring must be done by a quali
fi
ed electrician in
accordance with local codes or, in the absence of local
codes, with the
National Electrical Code, ANSI/NFPA 70
or
the
Canadian Electrical Code, CSA C22.1
.
Electrical Requirements
1595CFKV2—120 V, 60 Hz, less than 1 amp
GV60WIFI kits—120 V, 60 Hz, less than 1 amp
General Requirements
Optional 1595CFKV2 and WiFi module are powered by a
V-module (sold separately) which plugs into a grounded
receptacle installed within the
fi
replace enclosure by a
quali
fi
ed electrician.
Notes
• Fan speed control provided through remote handset.
• Receptacle and box must be located as per these
instructions. Wiring within this box must have a mini-
mum 90°C temperature rating.
Installation
1. Thread the cable through the cable clamp and
through the hole in the lower right hand corner of
the
fi
replace casing. Do not tighten the clamp yet..
Stud
Stud
Fireplace
Fireplace
casing
casing
Pull just enough cable
out front for now to make
termination easier
2. Provide a steel surface mount electrical utility
box (Iberville BC 1110 or equivalent), thread cable
through knock-out in the back of box and through
the cable clamp locking ring (if used).
3. Strip wire and terminate grounded receptacle.
4. Mount the electrical box to the side of the
fi
replace
casing using self-tapping sheet metal screws. Pull
the excess cable back through the cable clamp and
tighten the locking ring to the cable clamp. Alternate
clamp without locking ring may be used - ensure the
proper clamp is used for the type of cable used.
Installation
Electrical Wiring