Hot glass 

will cause burns.
Do not touch glass 

until cooled.
Never allow children 

to touch glass.

A barrier designed to reduce 

the risk of burns from the hot 

viewing glass is provided with this 

appliance and must be installed for 

the protection of children and 

other at-risk individuals.

DANGER

WARNING: 

FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings 

exactly could result in serious 

injury, death, or property damage.

Do not store or use gasoline or other 

fl

 ammable vapors and liquids in the 

vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do 

not use any phone in your building.

Leave the building immediately.

Immediately call your gas supplier from 

a neighbor’s phone. Follow the gas 

supplier’s instructions.

If you cannot reach your gas supplier, 

call the 

fi

 re department.

Installation and service must be 

performed by a quali

fi

 ed installer, service 

agency or the gas supplier.

Installer: Leave this manual with the appliance.

Consumer: Retain this manual for future reference.

Direct Vent Zero Clearance

Gas Fireplace

natural gas    1700KN

propane gas   1700KP

Installation Manual

L2

Содержание L2 1700KN

Страница 1: ...mmable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your b...

Страница 2: ...s reserved Designed and manufactured for Miles Industries Ltd Valor Fireplaces 190 2255 Dollarton Highway North Vancouver BC Canada V7H 3B1 T 604 984 3496 F 604 984 0246 valorfireplaces com This appli...

Страница 3: ...e cavity 26 Installation into existing adjacent chimney 27 Example of co linear conversion accessories 28 Installation 29 Appliance Preparation 29 Unpack Appliance 29 Fit Standoffs 29 Remove Heat Shie...

Страница 4: ...C depending on elevation of hearth Be careful of touching these Tem perature of projection surfaces will be reduced when barrier screens are installed Some materials or items although safe may discol...

Страница 5: ...ng a separate solid fuel burning ap pliance Each gas appliance must use a separate vent system Common vent systems are prohibited WARNING Do not operate this appliance with the glass front removed cra...

Страница 6: ...e left hand side of the firebox A shut o valve not supplied is required on the supply line to isolate the unit during service See Gas Supply Installation section for details Conversion Kits The 1700K...

Страница 7: ...t 1740SSL Stacked Stone Liners Trims choose one Barrier Screen 1730CIK Clean Install Kit Fine Mesh REQUIRES HeatShift 4007675 1750v2 Linear 3 1 2 Surrounds 4004221 1775LFB Linear 1 Finishing Trim Blac...

Страница 8: ...16 mm 383 18 1 2 470 mm 3 3 4 95 mm 4 102 mm 19 7 8 505 mm 32 3 8 822 mm 33 1 8 841 mm 14 1 2 2 369 m mm 9 3 8 238 m mm 52 1321 mm 49 11 16 1262 mm 1270RBK Remote Blower Kit outlet remove plate HeatSh...

Страница 9: ...Con tent sheet Also check that you have Fuel bed packed separately Liner panels packed separately Remote Battery and Wall Switch Kit HeatShift System components if used Gas conversion kit if necessary...

Страница 10: ...ent board must be non combustible Com mbustible mantel are ok provided they conform to chart on pag p g p ge p p p page g g g 11 Combustible Framing Allowed Beneath Fireplace When the appliance is ins...

Страница 11: ...Fireplace Opening Ceiling 24 Min to Ceiling 44 42 40 38 23 7 8 9 3 8 4 minimum to combustible or non combustible hearth Combustible Mantel Left Side View Installation Planning Mantel Clearances NOTE...

Страница 12: ...12 49 11 16 Fireplace Opening Wall Min 4 to wall or combustible mantel leg Face of Finished Wall FIREPLACE Combustible Sidewall Mantel Leg Top View Installation Planning Mantel Clearances...

Страница 13: ...ible framing allowed EHQHDWK UHSODFH KHQ WKH appliance is installed directly on carpeting tile or other combustible material other WKDQ ZRRG RRULQJ WKH appliance shall be installed on a metal or wood...

Страница 14: ...ipe Approx 10 3 4 274 mm from back surface of ZDOO QLVK WR front surface of appliance case w no YHQW R VHW 15 1 16 383 mm 14 1 2 369 mm 9 3 8 238 mm 19 1 4 489 mm Fireplace Opening PARTIAL SHELF top o...

Страница 15: ...erations Dimensions of venting are based on us ing Dura Vent elbows Elbow curve radius dimensions will vary when using other brands In general other brands have slightly bigger radius Minimum 24 inche...

Страница 16: ...Vertical Tube Furnace at 750 C shall be considered non combustible materials Combustible Materials made of or surfaced with wood compressed paper plant fibers plastics or other material that can igni...

Страница 17: ...stall BEFORE cement board Non Combustible Finishing Over Cement Board Additional non combustible material such as tile etc may be applied over top of the cement board or you may choose to leave it fin...

Страница 18: ...HeatShift System MUST be installed on this appliance when using 1730CIK Clean Installation Kit Always pre drill screw holes through cement board and use screws specific for material used Always use me...

Страница 19: ...stible wall assembly up to 8 inches in thickness A non combustible wall can be of any thickness up to the maximum horizontal run of vent pipe allowed for the particular installation Framing Vent in Co...

Страница 20: ...E WALL THIMBLE PIPE LENGTH PIPE LENGTH PIPE LENGTH PIPE LENGTH 90 ELBOW CEILING FIRESTOP ATTIC FIRESTOP ATTIC INSULATION SHIELD FLASHING STORM COLLAR VERTICAL TERMINATION PIPE LENGTH 90 ELBOW 90 ELBOW...

Страница 21: ...be used as long as they are within the allowable limits shown on the chart below 5 A maximum of 4 x 90 degrees elbows or equivalent 2 x 45 degrees 90 degrees can be used Excludes the 45 degrees take...

Страница 22: ...rear venting with no vertical rise The level of restriction required depends on the vertical rise in the venting system and to a lesser degree the horizontal run and number of elbows The amount of res...

Страница 23: ...ly located within 15 feet 4 6bm below the terminal 36 90 I Clearance to service regulator vent outlet 36 90 J Clearance to non mechanical air supply inlet to the building or the combustion air inlet t...

Страница 24: ...Vertical wall Min 24 unvented soffit Min 36 vented soffit Termination cap Min 18 Storm collar Roof flashing H Vertical Vent Termination Roof Pitch Minimum H feet Flat to 7 12 1 Over 7 12 to 8 12 1 5 O...

Страница 25: ...liner for intake and one 4 diameter liner for exhaust a 3 x 4 co linear termination kit and flashing Firebox zero clearance stando s supplied with the heater may be removed to suit this application R...

Страница 26: ...f vent system may only be installed within a solid fuel burning fireplace and chimney Installation partially into fireplace cavity The appliance can be adapted to co linear applications using an exist...

Страница 27: ...ssary If the installation does not allow for future inspection or replacement of the flexible aluminum venting then stainless steel vent liners should be used Note Co linear portion of vent system may...

Страница 28: ...Co linear Terminal Configurations Examples of Co axial to Co linear Appliance Adapters 10 10 3 Inlet Exhaust Collars 7 5 8 dia collar Flashing Kit Co Linear Terminal typical A 3 4 adapter may be used...

Страница 29: ...with barrier screen venting components and accessories optional HeatShift system if used electrical components if installing optional decorative light wall switch or blower Fit Stando s The stando s...

Страница 30: ...on of the heat shield on top of the heater case as indicated 1 Remove the top outlet collar 6 screws 2 Swivel the collar and install as a rear outlet 6 screws 3 Reinstall the heat shield to the top of...

Страница 31: ...nce out of its packing base and place it in the framing Make sure that the unit is at the right height with consideration to the height of the hearth or combustible flooring 3 Fold out four mounting t...

Страница 32: ...e the window locate the levers on each side of the window towards the top Using your fin ger pull the lever towards you and unhook it from the window frame bracket 2 Gently pull the top of the window...

Страница 33: ...ve the firebox inside the appliance case be removed to allow the hot air flow to convect upwards into ducts installed on the fireplace Remove the convection ba e from the appliance It is held in place...

Страница 34: ...ceptacle and box must be located as per these instructions Wiring within this box must have a mini mum 90 C temperature rating Installation 1 Thread the cable through the cable clamp and through the h...

Страница 35: ...e clamp on outside of fireplace casing and secure and excess wire to framing 6 Mount receptacle into electrical box 7 Mount steel cover to electrical box and plug in the accessory cable Installation E...

Страница 36: ...e resistant to the action of all gas constituents including LP gas Sealant should be applied lightly to male threads to ensure excess sealant does not enter gas lines Left side view Installation Gas S...

Страница 37: ...ual shut o valve Test for leaks by applying a liquid detergent or soap solution to all joints Bubbles forming indicate a gas leak The pressure test tapping locations are shown in the figure at right A...

Страница 38: ...identical Their step edges go towards the middle to fit into the middle section Rear panel sections top view Place the panel s right section on the ledge above the ports of the rear of the firebox The...

Страница 39: ...l of the firebox 8 Tighten the side panel anchors on each side of the firebox 9 Place the remaining rear panel s section behind the left side panel and fit its stepped edge to the stepped edge of the...

Страница 40: ...the steel platform around the burner as indicated The openings in the platform should be underneath 2 Carefully spread the vermiculite by hand on the surface of burner forming a single layer to the ap...

Страница 41: ...og Natural gas Place the log s left peg in the front hole Propane gas Place the log s left peg in the rear hole 2 Place the rear left log as indicated 3 Place the front left log as indicated Propane g...

Страница 42: ...esired 8 Place the rocks as shown below do not place di rectly on the burner WARNING Choking Hazard Ensure that the fireplace area is clear of vermiculite particles as these could be ingested by small...

Страница 43: ...bag and do not pour too much to avoid blocking the burner ports 4 Some fireglass may be added on the platform to cover the edge of the burner and in the space in front and behind the pilot shield NOT...

Страница 44: ...the kit as the logs are fragile 1 2 3 x 34 Installation 1 Install the steel platform around the burner as indicated no screws The openings in the platform should be underneath 2 Distribute the mixed s...

Страница 45: ...light 6 Place the first twig 1 as shown Use the bigger rocks to keep the twig o the shale as much as possible 2 2 1 7 Place twig 3 as shown over the center of the burner Use the bigger rocks to keep t...

Страница 46: ...lor fireplace The use of any other types of rocks twigs or shale may void your fireplace warranty WARNING Choking Hazard Ensure that the fireplace area is clear of shale pieces as these could be inges...

Страница 47: ...me logs straddle the burner Split Wood Kit 1700SWK Material required Black steel platform supplied with appliance Split Wood Kit which contains 1 bag of splinters 1 bag of small embers 11 logs Install...

Страница 48: ...r notch of log 6 Log 7 rests on front notch of log 6 Log 9 straddles the burner Log 8 rests on the notch of log 9 Log 10 rests on the rear right corner of the burner Log 11 rests on notch of log 10 In...

Страница 49: ...bers to avoid blocking the burner ports 3 Some embers may be added on the platform to cover the edge of the burner and the round holes 4 Spread some splinters to the embers Pilot shield NOTE Ensure th...

Страница 50: ...bers 8 cup bag 1 bag of splinters Carefully unpack the kit as the logs are fragile Installation 1 Install the steel platform around the burner as indicated no screws The openings in the platform shoul...

Страница 51: ...the pin in the hole as shown 6 Place log L4 on top of L5 and across the burner to the front platform L2 L1 L12 L2 L12 L5 L12 L5 L4 7 Place log L6 on top of L4 and onto the front plat form 8 Place log...

Страница 52: ...e The use of any other products may void your fireplace warranty WARNING Choking Hazard Ensure that the fireplace area is clear of embers splinters as these could be ingested by small children Vacuum...

Страница 53: ...m the front lower corner of the window re install it by sliding it between the glass and the frame as indicated WARNING The window unit must be correctly installed fastened and sealed after servicing...

Страница 54: ...3 Connect switch to auxillary 5 pin junction and power connection to jack 4 Run harness assembly to mounted position of junc tion box securing harness to framing using insu lated staples not included...

Страница 55: ...the snap connection load 4 AA alkaline bat teries into holder included with fireplace then feed back into junction box assembly Note Do not put batteries in the receiver only in the battery holder by...

Страница 56: ...t during the pairing se quence You will hear two short beeps confirming the pairing is done If you hear one long beep the pairing sequence has failed or the wiring is incorrect This is a one time pair...

Страница 57: ...re provided with the kit Cover the screws with the included caps to finish the mounting Once mounted the holder is magnetic simply place the remote gently into the holder IMPORTANT The location of the...

Страница 58: ...bed used altitude and other considerations the flame picture may be improved by adjusting the aeration The need for adjustment should be determined only by operating the appliance with the fuel bed p...

Страница 59: ...e instructions behind for the customer s further reference Installation Trim Barrier Screen WARNING HeatShift System MUST be installed on this appliance when using 1730CIK Clean Installation Kit 1730C...

Страница 60: ...ptional POWER V Module optional 120V Low voltage AC Power Fan optional FAN MAN Knob Combination Control Valve Main Valve Knob PANEL red yellow Receiver Antenna RESET Button RBWSK Connector Battery Hol...

Страница 61: ...iameter NOTE 2 ply liner approved to CAN ULC S635 suitable for venting gas appliances As manufactured by Z Flex Flexmasters or others 2280 Series AF3 35L AF4 35L TM ALK33 TM ALK43 TM ALT33 TM ALT34 95...

Страница 62: ...12 4DT AF12 TF 4FB SV4B 4DF12 6 12 12 12 949606712 Flat Roof Flashing 46DVA FF TF 4F SV4F 949606001 Masonry Flashing TF 4MF 559FSK New Siding Flashing 658NSFK Various Venting System Parts Wall Thimble...

Страница 63: ...t at the time of completion of installation the owner shall have a period of thirty 30 days to comply with the above requirements provided however that during said thirty 30 day period a battery opera...

Страница 64: ...flue gases but identifies special venting systems the following requirements shall be satisfied by the manufacturer 1 The referenced special venting system instructions shall be included with the appl...

Страница 65: ...FOHDU RXW DQ JDV WKHQ VPHOO IRU JDV LQFOXGLQJ QHDU WKH RRU If you VPHOO JDV 6723 ROORZ LQ WKH VDIHW LQIRUPDWLRQ DERYH RQ WKLV ODEHO I RX GRQ W VPHOO gas go to the next step 3 AUTOMATIC IGNITION 0 1 N...

Страница 66: ...CAUTION Always check the re and pilot visu ally to ensure they are o AM ON OFF PM AM Mode Thermostatic Mode Signal Indicator Child Proof Light Fan if included Program Mode Temperature Time Auxiliary...

Страница 67: ...untdown Timer AM AM To deactivate functions 1 Install batteries All icons are displayed and ashing 2 While the icons are ashing press the relevant func tion button and hold for 10 seconds 3 The functi...

Страница 68: ...only works in Manual Thermostatic and Eco modes Maximum countdown time is 9 hours and 50 minutes Light Dimmer Operation On Press is displayed Light is on at preset level Off Press disappears Light tur...

Страница 69: ...WiFi the handset will display APP Manual Mode The on o status of the replace as well as ame height are manually controlled by the user PM ON OFF PM PM Thermostatic Mode On Press is displayed Preset t...

Страница 70: ...To con rm press ON ON Off Time Setting PROGRAM 1 1 1 OFF are displayed ALL is displayed brie y Hour ashes 2 To select hour press or 3 To con rm press 1 OFF are displayed ALL displayed brie y Minutes...

Страница 71: ...imum countdown time is 9 hours and 50 minutes CAUTION Do not use a screwdriver or other metallic object to remove the batteries from the battery holder or the handset This could cause a short circuit...

Страница 72: ...no pilot ame No gas supply Air in pilot supply line No spark Reversed polarity in thermocouple wiring Incorrect pilot ori ce if valve has been converted from LPG to NG or vice versa F07 Low battery s...

Страница 73: ...gradually increase flame height Press and hold small flame button to gradually decrease flame height The Wall Switch can be used to control your fireplace You can turn the pilot on or o and you can i...

Страница 74: ...inear with HeatShift Instructions for use with the following Valor Heater Models 1500 1600 1700 and 1800 J or K Incompatible with earlier models 1500I 1600I and 1700I WARNING DO NOT cover or place obj...

Страница 75: ...n Plates 2 for wall valance discharge ONLY 7 3 4 197 mm LDK1 48 x 2 LDK4 38 x 2 LDK3 2 14 x 6 2 14 x 6 grilles included white 4 take off collars included 4 take off collars included 4 take off collars...

Страница 76: ...with LDK4 LDK6 5 dia Aluminum 2 ply Flex Kit 2 x 10 0 lengths may be cut to required length 3 5 8 92 mm 3 5 8 92 mm LDK6 2 10 x 5 aluminum ex LDK5 supplied separately 38 frame white LDK2 supplied sep...

Страница 77: ...ace Conversion Kit instructions Rear wall outlets using LDK3 With LDK7 Corner installations Note When using LDK7 the discharge opening must be located in the same room as the fireplace WARNING The ple...

Страница 78: ...Class 1 Air Duct 4 use LDK6 kit or equivalent Min 2 1 2 clearance to ceiling Min 30 Max 12 0 See table for offsets Linear 32 3 8 LX2 33 1 4 Linear 8 1 2 LX2 5 1 4 Linear 14 1 2 LX2 17 Linear 9 3 8 LX2...

Страница 79: ...kit or equivalent Min 2 1 2 opening required at ceiling Min 30 Max 12 0 6HH WDEOH IRU R VHWV Min 14 32 3 8 8 1 2 14 1 2 9 3 8 Ceiling Min 1 clearance to combustibles around pipe NOTE Discharge openin...

Страница 80: ...ntal Offset X offset for take off that s furthest away Ceiling LDK 1 LDK 3 or LDK 4 Min bend radius Top of fireplace Min 1 clearance to combustibles around pipes Support horizontal sections of pipe us...

Страница 81: ...mounting bracket and 1 2 standoff 3 1 2 standoff 3 5 8 7 7 8 11 1 2 Top View Front View Right Side View LDK 4 38 LDK 4 5 dia collars 4 C L 8 14 8 4 4 3 3 5 8 7 7 8 11 1 2 1 2 standoff Front View Top...

Страница 82: ...1 2 9 3 4 9 3 4 Stand offs fold down for shipping Warning Label Stand offs Front View Top View Right Side View LDK 3 14 C L 7 6 5 dia collars 2 3 mounting bracket and 1 1 2 standoff mounting bracket...

Страница 83: ...gh Frame Opening Rough Frame Opening See appliance s installation for minimum combustible cavity dimensions Note Min cavity dimensions may be dictated by LDK plenum when installing across corners Min...

Страница 84: ...arance to ceiling 1 2 5 1 2 min clearance to combustibles rear sides 1 min clearance to combustibles all around pipes Plenum support wood Maintain 1 clearance to pipes Framing on edge 1 1 2 min cleara...

Страница 85: ...e to support plates as necessary maintain 1 clearance to pipes DOO QLVK UHTXLUHG to form plenum above duct termination plates LDK 7 Duct Termination Plates 2 for horizontal installation ONLY Continuou...

Страница 86: ...d off Non combustible zone above plates Perimeter of plates may be trimmed to suit installation Combustible framing allowed below plates 5 dia pipes maintain 1 clearance to combustible materials Front...

Страница 87: ...XFW LWV 8QLYHUVDO WDNH R VXSSOLHG ZLWK 5 NLW DQ PRXQW WR HLWKHU HQG RI SOHQXP 0D LPXP 5 NLW SHU SOHQXP 1RWH 2 127 211 7 5 GLUHFWO WR UHSODFH ZKHQ XVLQJ XFW LW FRQQHFW WR SOHQXP 21 DV WKLV ZLOO HQVXUH...

Страница 88: ...23 3 4 29 3 4 33 3 4 45 NOTE These Mantel Clearances apply ONLY when LDK Duct system is installed Mantel Height from Bottom of Unit COMBUSTIBLE Mantel Clearances Linear appliances when using HeatShif...

Страница 89: ...ase be removed to allow the hot air ow to convect upwards into ducts installed on the replace Remove the convection ba e from the appliance It is held in place by screws located right behind the upper...

Страница 90: ...O U R 4 t a k e o f f s M U S T B E C O N N E C T E D T O P L E N U M S Install HeatShift collars 1 Remove the four cover plates on top of the appli ance case 6 screws each 1500 1700 1800 J or K 1500...

Страница 91: ...Class 1 approved air duct to each of the collars and secure it with gear clamps provided DO NOT SPLICE DUCTS 5 Attach the top of the pipe sections to the plenum securing them with the gear clamps pro...

Страница 92: ...upward slope must be maintained in horizontal sections of pipes for proper convection Use straps as necessary to maintain the pipes posi tions Support horizontal sections every 24 inches 6 Continue w...

Страница 93: ...93 Appendix D HeatShift System LDK4 LDK3 LDK5 LDK6 LDK2 LDK7 LDK1...

Страница 94: ...r stopper 4008005 37 Injector Burner mount 4007702 Description Part No 38 Gas orifice DMS 32 natural gas 4007000 32 Gas orifice DMS 49 propane gas 4007000 49 39 Air shutter 4007748 40 Burner module pl...

Страница 95: ...5 4007375 Birch Log L6 4007376 Birch Log L8 4007378 Birch Log L9 4007379 Birch Log L12 4007382 107 GV60 Valve Repair Kit 4004544 Description Part No 63a Rear panel Fluted Black sides 2 4003727 Glass L...

Страница 96: ...2 3 6 6 4 4 5 7 12 10 16 15 14 18 17 9 13 11 60a 60b 60c 60d 60e 60f 60g 60h 60i 60 8 8 19 20 21 52 53 22 29 30 32 34 35 59 107 66 64 63 65 62 63a 63a 66 23 24 28 31 33 36 37 38 39 40 41 43 44 45 46...

Страница 97: ...1 72 73 83 82 81 80 79 78 77 74 75 76 68c 68d 68b 68a 68f 68e 68f 68e 98 88 85 86 87 89 90 91 67 84 102 100 101 99 69 92 93 94 97 96 95 7 8 5 2 2 5 2 2 1714RSS 1705DWK 1700SWK 1700DGM 2 1 2 3 4 5 6 7...