Appendix D—HeatShift System
Suggested Con
ȴ
gurations
Side wall outlets using LDK3
Not to scale
NOTE This duct kit may also be used for outdoor
installations where reduced wall surface
temperatures above the unit are desired.
The discharge grilles must be located under
the weatherproof enclosure described in the
GV60CKO Outdoor Fireplace Conversion Kit
instructions.
Rear wall outlets using LDK3
With LDK7
Corner installations
Note - When using LDK7, the discharge opening
must be located in the same room as the fireplace.
Ʉ
WARNING
The plenum duct kits are approved
for horizontal discharge ONLY. The
termination duct plates are approved
for vertical upward discharge ONLY. DO
NOT install plenum or termination plates
in
ȵ
oor or ceiling. DO NOT COVER OR
PLACE objects in front of or on top of air
outlet(s). AVOID locating outlet within
7 feet of the
ȵ
oor level as discharge air
temperatures are hot!
D O N O T D I S C H A R G E T H R O U G H
E X T E R I O R W A L L S !
Note: Vertical venting straight
o
1600K heater will NOT
clear 38” (LDK4) or 48” (LDK1)
plenums without o
setting
vent around plenum.
Note: Take-
o
collars
staggered,
2 per side
1600K L1 see-thru using LDK1, LDK4 or LDK9
CL
Axe central du foyer
et du plenum
Centerline of heater
and plenum
Front wall outlet using LDK1, LDK4 or LDK9
Rear wall outlet using LDK1, LDK4 or LKD9
Note: Fireplace vent may con
ȵ
ict with plenum.
O
set vent around plenum.