![Valor HORIZON 534JN Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/valor/horizon-534jn/horizon-534jn_installation-and-owners-manual_3647126045.webp)
45
Check Operation
Turn the fi replace fl ame up and down using the
remote control to confi rm that the full range of inputs
is achieved—see the remote control operation
instructions starting on page 8.
Adjust Aeration (if needed)
Light the fi re and allow the unit to warm up for 10–15
minutes to evaluate the fl ame picture. Burners are
equipped with an adjustable shutter to control primary
aeration. See the fi gures below. The shutter is
factory-set to an aeration gap which will give optimum
performance for the vast majority of installations.
In some installations, depending of the fuel bed used,
the altitude and other considerations, the fl ame picture
may be improved by adjusting the aeration. The need
for adjustment should be determined only by operating
the appliance with the fuel bed and window installed
and evaluating the fl ame picture after a 15-minute
warm-up.
Increasing aeration
will cause the fl ames to appear
more transparent and blue showing more ceramic
eff ects glow.
Decreasing aeration
will cause the fl ames to appear
more yellow or orange showing less ceramic eff ects
glow.
Too little aeration may result in black carbon
forming and dropping into the
fi
rebox.
Air Shutter
Open
Open
Close
Close
Natural gas
Flashback shield
(propane only)
Air Shutter Slider
(propane gas)
Open
Close
Propane gas
Air Shutter
Slider & Cover
(natural gas)