![Valor HORIZON 534JN Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/valor/horizon-534jn/horizon-534jn_installation-and-owners-manual_3647126017.webp)
17
Thermocouple
probe must be
in flame
Correct fl ame appearance
534LSK—Traditional Logs
534RSK—Rocks
534DWK—Driftwood
Servicing & Maintenance
Checking Pilot and Burner Flames
A periodic check of the pilot and burner fl ames should
be made. Check after the fi re has been on for at least
30 minutes. The pilot fl ame must cover the tip of the
thermocouple probe. The main burner fl ame pattern will
vary from appliance to appliance depending on the type
of installation and climatic conditions.
The appliance area must always be kept clear and
free from combustible materials, gasoline and other
fl ammable vapors and liquids. Inspect the vent terminal
outdoors regularly to make sure that dirt, snow, insects,
leaves, shrubs, trees do not obstruct it. Examine the
whole vent system regularly. We recommend annually.
Rock fuel bed
A black discoloration may form over time at the front
bottom of the 6-rock original fuel bed; this deposit
can be burned off by running the fi replace on a low
to medium setting fi re for 30 to 45 minutes. This
discoloration is unavoidable and will re-form again.
Pilot Flame can be seen on
the left side of the fuel bed
OWNER’S
INFORMATION