The
burner
settings
are:
•
We recommend that the fire is set at position 4 for the first 10 minutes after lighting
to warm up the chimney and so obtain full efficiency quickly.
•
If operating the appliance for long periods it is beneficial occasionally to change the
settings. This will also help to remove any carbon deposits that may form during
operation.
Note: If the fire goes out while setting the control, repeat the full lighting procedure. If
the fire repeatedly goes out, have the fire serviced.
To turn the fire off.
•
Partially depress the control knob and turn clockwise to OFF. Release the knob.
•
Wait at least 3 minutes after turning the fire off before relighting.
Page 38
©
GDC Group Ltd. 2012
OWNER GUIDE
Control Knob
Position
Burner appearance
1 / IGN
Centre section on low. Outer sections off.
2
Centre section fully on. Outer sections off.
3
Centre section fully on. Outer sections on low.
4
All sections fully on.