12.9 To remove the complete burner module, pipes and pilot.
1.
Remove the fascia as section 12.2.
2.
Remove the ceramic fuel effect as
section 12.4.
3.
Support the inlet ‘T’ connector to avoid
straining the pipework and disconnect
the appliance.
4.
Detach the gas tap bracket from the
right side of the appliance by removing
three screws (See figure 18).
5.
Detach the left side of the burner from
the firebox by removing one screw (See
figure 18).
6.
Free the burner & pilot module from
the rear pilot air pipe and the firebox by
carefully sliding the module to the right
while pulling it slightly (See figures 18
and 19).
7.
Remove the pipes, or pilot unit if
required.
8.
Replace in the reverse order.
Note: 1. The pilot unit is an atmosphere
sensing device. It must be
replaced as a whole
assembly. Its individual
components are not
separately replaceable.
2. If the pilot is removed,
when refitting, make sure that
the pilot heat shield is in place
between the pilot unit and the
rear of the burner and is the
correct way round (See figure
19).
3. Check that there is no
blockage of the air intake tube
at the back of the pilot unit.
Make sure that the air intake
tube locates fully into the pilot air pipe attached to the back panel (See figure
19).
Page 30
©
GDC Group Ltd. 2012
INSTALLER GUIDE
Figure 19. Pilot air pipe location
Figure 18. Burner module removal