DO NOT USE thermostatic handset supplied with 

appliance when installing outdoors!

USE 1265WSK or RBWSK (appliance installed under 

overhang)

FIREPLACE

BATTERY

ACCESS

UP

ON-OFF

DOWN

ACCÈS

PILES

DU FOYER

X X

Use with Valor Zero Clearance heater models 530, 534, 650, 1000, 1100, 1150, 1400, 

1500, 1600, 1700, 1800 and Insert heater models 700, 738K, 739, 780, 785, RF24KB, 

RF24JD installed into existing approved solid-fuel burning fireplaces having weather 

protection as specified in this manual.

GV60 Outdoor Fireplace Conversion Kit

INSTALLATION MANUAL

GV60CKO

© Copyright Miles Industries Ltd., 2021.

WARNING

This conversion kit shall be installed by 

a qualified service agency in accordance 

with the manufacturer’s instructions and 

all applicable codes and requirements 

of the authority having jurisdiction. If 

the information in these instructions is 

not followed exactly, a fire, explosion 

or production of carbon monoxide may 

result causing property damage, personal 

injury or loss of life. The qualified service 

agency is responsible for the proper 

installation of this kit. The installation 

is not proper and complete until the 

operation of the converted appliance is 

checked as specified in the manufacturer’s 

instructions supplied with the kit.

Use this manual in conjunction with the 

installation manual supplied with the 

appliance.
LEAVE THIS MANUAL WITH THE HOMEOWNER.

WARNING

Electrical shock hazard - Do not install 

electrical accessories (fans, lighting, wifi) 

when converting the appliance for use 

outdoors.

General notes regarding conversion

This manual contains instructions for adapting natural 

gas or propane models listed above for use outdoors. 

For the purpose of this manual the term “outdoor” 

means installed outside of the insulated building 

envelope within a weatherproof enclosure or existing 

solid-fuel burning fireplace having a minimum required 

overhang. The outdoor space may be attached or free 

standing to the main/primary structure and may or may 

not include walls. See page 6 for further information 

regarding locating your outdoor fireplace.
Use this manual in conjunction with the installation 

manual supplied with the appliance. The outdoor 

fireplace must be permanently situated and connected 

to a fixed piping system and must not be portable.

Notes

•  No electrical accessories (fans, lighting or wifi) per-

mitted when adapting the appliance for outdoor use.

•  Any of the optional available trims and fronts may 

be used in the outdoor environment including 

optional HeatShift components although please 

note that some fading or corrosion may occur due to 

environmental conditions.

 Cast iron fronts are not 

recommended outdoors.

•  Thermostatic controls are not allowed for outdoor 

fireplaces. Use the wall switch supplied with the 

appliance or when not supplied, order an optional 

RBWSK Remote battery and wall switch kit to control 

the appliance. 

Do not use the thermostatic remote 

controled handset supplied with the appliance!

1265WSK–

Wall Switch

RBWSK–

Remote Batteries & 

Wall Switch Kit

Содержание GV60CKO

Страница 1: ...ard Do not install electrical accessories fans lighting wifi when converting the appliance for use outdoors General notes regarding conversion This manual contains instructions for adapting natural ga...

Страница 2: ...supplied separately to the outdoor receiver see installation instructions supplied with the kit Valve Wire Harness Red Yellow Wall Switch Harness RBWSK Remote Battery Wall Switch kit power connector...

Страница 3: ...er and turning the gas shut off valve to the off position Upon ensuring the fireplace cannot be turned on you can then apply a weather protective cover over the front of the fireplace to help preserve...

Страница 4: ...switch 1 Wait ve 5 minutes to clear out any gas then smell for gas including near the oor If you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the...

Страница 5: ...m as an exterior wall If installed against an exterior wall we recommend the appliance enclosure or chase be constructed completely outside of the insultated building envelope and weather membrane The...

Страница 6: ...fireplace insert 1600 See through Continuous insulated building envelope and weatherproof membrane is NOT interrupted by fireplace installation INSIDE INSIDE OUTSIDE Min weatherproof overhang in front...

Страница 7: ...914 mm of front of appliance Min required weatherproof overhang Combustible Overhang 54 Min to Combustible Overhang non combustible construction permited lower Note Use of the optional HeatShift Syst...

Страница 8: ...30 of the total perimeter wall area surrounding the outdoor space must be openings KEY VENT TERMINAL LOCATIONS MINIMUM DISTANCES Measured from the center of vent MINIMUM CLEARANCE Inches Cm A Clearanc...

Страница 9: ...install repaired or replacement parts f The initial owner of the unit will be responsible for any shipping charges for replacement parts as well as travel time incurred by the dealer to perform the wa...

Страница 10: ...ral fourni avec le foyer ou lorsque non fourni commandez le Porte piles et interrupteur mural RBWSK pour contr ler le foyer NE PAS UTILISER la manette thermostatique de t l commande fournie avec l app...

Страница 11: ...s avoir rebranch toutes les connexions 7 V rifiez le fonctionnement de l interrupteur con sultez le guide du foyer ou de l interrupteur mural pour savoir comment fonctionne l interrupteur Harnais conn...

Страница 12: ...gaz en position off En vous assurant bien que le foyer ne peut se rallumer vous pouvez en couvrir la devanture avec une paroi de protection l preuve des intemp ries afin d en pr server le fini et de...

Страница 13: ...AUTOMATIQUE Bouton MAN ON 2 Assurez vous que le bouton de r glage des ammes 3 est au r glage le plus bas 3 g 1 Rep rez la veilleuse g 3 dans la bo te de foyer Sur l interrupteur mural appuyez le bouto...

Страница 14: ...lure des murs ou non Note Le foyer ne peut tre install titre de mur ext rieur Si le foyer est install contre un mur ext rieur nous conseillons la construction de l encastrement ou de la charpente comp...

Страница 15: ...existant Encastrement l preuve des intemp ries Enveloppe isolante continue de l difice et membrane l preuve des intemp ries NE SONT PAS interrompues par l installation du foyer Taille minimale du surp...

Страница 16: ...du foyer Minimum 54 1372 mm jusqu au surplomb construction incombustible permise plus bas Surplomb minimum l preuve des intemp ries exig Note L utilisation du Syst me Heat Shift optionnel affecte les...

Страница 17: ...l partir de l axe central du compteur r gulateur situ moins de 15 pieds 4 6 m sous la sortie d vacuation 36 90 I D gagement partir de la sortie d air vici du r gulateur 36 90 J D gagement partir d une...

Страница 18: ...euses ou la r installation de pi ces r par es ou remplac es f Le propri taire original de l appareil sera responsable des frais d exp dition pour le remplacement de pi ces de m me que des frais de d p...

Отзывы: