Valor Dream Fireslid 9500433 Скачать руководство пользователя страница 9

the “V” shaped brackets near the bottom 
front sides of the convection box (see 
figure 10).

5.7

Place the convection box fully back into 
the fireplace opening so that it is sealed 
against the fireplace front surround.

5.8

Fit a cable retainer over the bottom end of
each cable (see figure 10).

5.9

Pull each cable taut. Push the cable 
retainers hard up against the “V” 
brackets.  
Tighten the screws in the retainers so that
they clamp the cables in position. Apply 
tension to the cables by turning the 
hexagonal adjusters by hand
(see figure 10).

5.10

Inspect the installation of the convection 
box against the fireplace surround. If the 
convection box is aligned squarely and 
the sealing is satisfactory, fully tighten the
cable retainers.

5.11

If the convection box is not correctly 
aligned, release the tension on the cables 
by slackening the screws and turning the 
hexagonal adjusters fully anticlockwise.
The convection box should then 
automatically realign itself. Pull each cable
taut again and push the cable retainers 
back against the “V” brackets. Again, 
tighten the screws in the retainers and 
apply tension to the cables by turning the 
hexagonal adjusters clockwise as far as 
possible.

5.12

Store the free length of the cables in 
convection box. This will allow easy 
removal and refitting of the appliance 
during subsequent service calls.

5.13

Using the floor sealing tape supplied, seal 
the bottom of the convection box to the 
fireplace and hearth floor (see figure 11).

Make sure that the whole length of the 
front edge of the convection box is fully 
sealed.

6.1

Refit the burner unit to the convection box
with two screws. Make sure that the 
tab at the right side of the battery box is 
in front of the “L” shaped bracket which 
projects up from the fire case base. 
See figure 11A.

6.2

Reconnect the slider control linkage firmly
to the burner control pivot with the 
shouldered screw using a screwdriver 
(Not finger tight only).

Page 9

INSTALLER GUIDE

6.BURNER & FASCIA

INSTALLATION

figure 10 

Cable retention arrangement

figure 11

Floor sealing

figure 11A 

Burner fitting

Valor 600B610_01  7/12/00  3:22 PM  Page 9

Содержание Dream Fireslid 9500433

Страница 1: ...31 THIS APPLIANCE IS FOR USE IN THE UNITED KINGDOM GB AND THE REPUBLIC OF IRELAND IE ONLY We trust that these instructions give sufficient details to enable this appliance to be installed and maintain...

Страница 2: ...high standards of safety quality and performance Careful Installation Valor is a Corgi registered company All our gas fires must be installed by a competent Corgi Registered Installer in accordance wi...

Страница 3: ...RATING CHECKS 12 Check the Fireslide control 12 Check For Spillage 13 FINAL REVIEW 14 SERVICING PARTS REPLACEMENT 14 To remove the ignition microswitch 15 To remove the gas shut off microswitch 15 To...

Страница 4: ...tu h Burner Test Pressure Cold 17 3 0 75mbar 35 1 0 75mbar 7 0 0 3in w g 14 1 0 3in w g Gas Connection 8mm pipe 8mm pipe Burner Injector Bray Cat 31 Size 440 Bray Cat 18 Size 190 Pilot Atmosphere Sens...

Страница 5: ...earth to the underside of any shelf made from wood or other combustible materials is as follows For a shelf up to 150mm deep Minimum height 750mm For a shelf deeper than 150mm 750mm 12 5mm for every 2...

Страница 6: ...removal 2 12 The flue must not be used for any other appliance or application 2 13 If the fireplace opening is of underfloor draught type it must be sealed to stop any draughts 2 14 An extractor fan...

Страница 7: ...the actual surround is used as a template to mark the area for combustible cladding removal 3 4 Fireplace Flue Pull After preparing the fireplace carry out the flue flow test as detailed in BS5440 Par...

Страница 8: ...quidistant each side of the centre line of the fireplace to ensure that the appliance finishes centrally in the opening when tension is applied to the cables 5 3 Insert a fibre plug into each hole Use...

Страница 9: ...itself Pull each cable taut again and push the cable retainers back against the V brackets Again tighten the screws in the retainers and apply tension to the cables by turning the hexagonal adjusters...

Страница 10: ...up to four seconds between the pilot lighting and ignition of the gas at the main burner This is normal and is due to the time required to fill the main burner compartment with sufficient gas for igni...

Страница 11: ...burner compartment See figure 15 7 2 Place the rear base coal in the burner compartment behind the front coal It should rest on the ledge at the back of the burner compartment The projections at the s...

Страница 12: ...d the second row of coals See figure 21 8 1 Check the control The control position markings on the front surround are shown in figure 22 When first turned on from cold the flames will appear predomina...

Страница 13: ...casting in position 8 2 1 Close all doors and windows in the room containing the appliance 8 2 2 Light the appliance and set the slide control to the maximum burning position 8 2 3 Leave the appliance...

Страница 14: ...osits that may have formed during previous use If using the appliance for long periods it is beneficial to change between settings This will also help to remove any carbon deposits that may form durin...

Страница 15: ...soundness and spillage after servicing the appliance 10 1 To remove the ignition microswitch Figures 24 25 The ignition microswitch is stamped V4NT9C4YC 10 1 1 Remove the ash pan casting and bottom f...

Страница 16: ...4 Support the inlet isolating elbow to avoid straining the pipework and disconnect the appliance from the elbow 10 4 5 Detach the burner unit from the convection box by removing two screws see figure...

Страница 17: ...the gas shut off tap 10 7 3 Detach the thermocouple from the interrupter block by unscrewing the thermocouple nut 10 7 4 Detach the electrode lead from the underside of the electrode tab 10 7 5 Remov...

Страница 18: ...has actuated the ignition microswitch but before it has pushed the microswitch leaf against the microswitch body When refitting the thermocouple and interrupter block make sure that the microswitch wi...

Страница 19: ...on The left side of the plaque must touch the inside edge of the retaining flange at the left side of the burner well 10 11 6 Place the new right hand plaque in position Make sure that the centre sect...

Страница 20: ...Pilot unit For Propane Gas Appliances 544929 G Injector Bray cat 31 size 440 For Natural Gas Appliances 1 569539 Injector Bray cat 18 size 190 For Propane Gas Appliances 569419 H Igniter unit 1 554949...

Страница 21: ...If you require your fire to be serviced please contact Valor Service on 0121 386 6203 and quote the following details a model name and number b appliance serial no To be found below the burner and be...

Страница 22: ...ner compartment so that it rests on the edges at the sides and front Pull the coal forward so that it is immediately behind the front rim of the burner compartment See figure 3 2 Place the rear base c...

Страница 23: ...with a slightly damp cloth and then dry Do not use abrasive cleaners they could scratch the surface Ceramic Coals This product uses a fuel effect pieces containing Refractory Ceramic Fibres RCF which...

Страница 24: ...d to light the pilot the battery may need replacing Details of battery replacement are given further on in this manual Until you can obtain a replacement battery the fire can be lit with a taper as de...

Страница 25: ...Never put any paper or other material on the fire Never add any extra coals above the number stated in these instructions This could cause a safety hazard 7 It should be appreciated that although thi...

Страница 26: ...ears trouble free service Your owner guide aims to improve your understanding and appreciation of your Valor gas fire by providing simple and informative instructions to ensure that you benefit from t...

Страница 27: ...igh standards of safety quality and performance Careful Installation Valor is a Corgi registered company All our gas fires must be installed by a competent Corgi Registered Installer in accordance wit...

Страница 28: ...e using your gas fire and keep for future reference This Owner manual gives sufficient details to enable your gas fire to be operated and maintained However if further information is required our Valo...

Отзывы: