9.1

Place the fire front castings in position.

9.2

Visually inspect the appliance. Clean off 
any marks incurred during installation.

9.3

Hand this guide and the owner’s guide to 
the customer.

9.4

Advise the customer how to operate the 
appliance. Point out that lighting 
instruction details are on the metal plate 
attached at the bottom of the appliance 
(Leave the plate visible in front of the 
bottom front cover as a reminder.

9.5

Explain to the customer that the appliance
has a flame failure & spillage monitoring 
system. Point out the explanation of this 
system shown in the owner’s guide under 
“Operating the fire”. Advise that if the fire 
goes out for any reason, wait at least 
three minutes before relighting.
Stress that if the monitoring system 
repeatedly shuts off the fire, the appliance
should be switched off and a specialist 
should be consulted.

9.6

Advise the customer that they should read
their Owner’s guide before operating the 
fire and always follow the advice in the 
section headed “Cleaning”.

9.7

Stress that no extra coals must be added
over and above those supplied with the
appliance and that any replacements 
must only be the authorised spares. 
Warn that ignoring this advice could 
cause incomplete clearance of the 
products of combustion with consequent
health hazards.

9.8

Advise the customer that the appliance 
will operate to its maximum potential if 
the flue is primed during the first 20 - 30 
minutes of use. To do this, simply slide 
the control to its highest setting. This will 
also burn off any carbon deposits that 
may have formed during previous use. 
If using the appliance for long periods it is
beneficial to change between settings. 
This will also help to remove any carbon 
deposits that may form during use.

This is explained in the Owner’s manual 
under the section ‘Operating the Fire’.
Point this out to the customer before 
leaving.

9.9

Recommend that the appliance should be 
serviced and the chimney inspected by a 
competent person (In the UK a CORGI 
registered person) at least annually.
If the appliance is in premises in the 
United Kingdom occupied by a tenant, 
point out that by law a landlord must have
any gas appliance, flue and pipework 
which is situated in a tenant’s premises 
checked for safety at least every 12 
months.

Always turn off the gas supply before 
commencing any servicing (The inlet 
elbow for this appliance incorporates an 
isolating valve).

This product uses fuel effect pieces, 
containing Refractory Ceramic Fibres 
(RCF), 
which are man-made vitreous silicate 
fibres. Excessive exposure to these 
materials may cause temporary 
irritation to eyes, skin and respiratory 
tract. Consequently, it makes sense to 
take care when handling these articles 
to ensure that the release of dust is kept
to a minimum. To ensure that the 
release of fibres from these RCF articles
is kept to a minimum, during installation
and servicing we recommend that you 
use a HEPA filtered vacuum to remove 
any dust and soot accumulated in and 
around the fire before and after working 
on the fire. When replacing these 
articles we recommend that the replaced
items are not broken up, but are sealed 
within a heavy duty polythene bag,

Page 14

INSTALLER GUIDE

9.FINAL REVIEW

10.SERVICING & PARTS

REPLACEMENT

Valor 600B610_01  7/12/00  3:22 PM  Page 14

Содержание Dream Fireslid 9500433

Страница 1: ...31 THIS APPLIANCE IS FOR USE IN THE UNITED KINGDOM GB AND THE REPUBLIC OF IRELAND IE ONLY We trust that these instructions give sufficient details to enable this appliance to be installed and maintain...

Страница 2: ...high standards of safety quality and performance Careful Installation Valor is a Corgi registered company All our gas fires must be installed by a competent Corgi Registered Installer in accordance wi...

Страница 3: ...RATING CHECKS 12 Check the Fireslide control 12 Check For Spillage 13 FINAL REVIEW 14 SERVICING PARTS REPLACEMENT 14 To remove the ignition microswitch 15 To remove the gas shut off microswitch 15 To...

Страница 4: ...tu h Burner Test Pressure Cold 17 3 0 75mbar 35 1 0 75mbar 7 0 0 3in w g 14 1 0 3in w g Gas Connection 8mm pipe 8mm pipe Burner Injector Bray Cat 31 Size 440 Bray Cat 18 Size 190 Pilot Atmosphere Sens...

Страница 5: ...earth to the underside of any shelf made from wood or other combustible materials is as follows For a shelf up to 150mm deep Minimum height 750mm For a shelf deeper than 150mm 750mm 12 5mm for every 2...

Страница 6: ...removal 2 12 The flue must not be used for any other appliance or application 2 13 If the fireplace opening is of underfloor draught type it must be sealed to stop any draughts 2 14 An extractor fan...

Страница 7: ...the actual surround is used as a template to mark the area for combustible cladding removal 3 4 Fireplace Flue Pull After preparing the fireplace carry out the flue flow test as detailed in BS5440 Par...

Страница 8: ...quidistant each side of the centre line of the fireplace to ensure that the appliance finishes centrally in the opening when tension is applied to the cables 5 3 Insert a fibre plug into each hole Use...

Страница 9: ...itself Pull each cable taut again and push the cable retainers back against the V brackets Again tighten the screws in the retainers and apply tension to the cables by turning the hexagonal adjusters...

Страница 10: ...up to four seconds between the pilot lighting and ignition of the gas at the main burner This is normal and is due to the time required to fill the main burner compartment with sufficient gas for igni...

Страница 11: ...burner compartment See figure 15 7 2 Place the rear base coal in the burner compartment behind the front coal It should rest on the ledge at the back of the burner compartment The projections at the s...

Страница 12: ...d the second row of coals See figure 21 8 1 Check the control The control position markings on the front surround are shown in figure 22 When first turned on from cold the flames will appear predomina...

Страница 13: ...casting in position 8 2 1 Close all doors and windows in the room containing the appliance 8 2 2 Light the appliance and set the slide control to the maximum burning position 8 2 3 Leave the appliance...

Страница 14: ...osits that may have formed during previous use If using the appliance for long periods it is beneficial to change between settings This will also help to remove any carbon deposits that may form durin...

Страница 15: ...soundness and spillage after servicing the appliance 10 1 To remove the ignition microswitch Figures 24 25 The ignition microswitch is stamped V4NT9C4YC 10 1 1 Remove the ash pan casting and bottom f...

Страница 16: ...4 Support the inlet isolating elbow to avoid straining the pipework and disconnect the appliance from the elbow 10 4 5 Detach the burner unit from the convection box by removing two screws see figure...

Страница 17: ...the gas shut off tap 10 7 3 Detach the thermocouple from the interrupter block by unscrewing the thermocouple nut 10 7 4 Detach the electrode lead from the underside of the electrode tab 10 7 5 Remov...

Страница 18: ...has actuated the ignition microswitch but before it has pushed the microswitch leaf against the microswitch body When refitting the thermocouple and interrupter block make sure that the microswitch wi...

Страница 19: ...on The left side of the plaque must touch the inside edge of the retaining flange at the left side of the burner well 10 11 6 Place the new right hand plaque in position Make sure that the centre sect...

Страница 20: ...Pilot unit For Propane Gas Appliances 544929 G Injector Bray cat 31 size 440 For Natural Gas Appliances 1 569539 Injector Bray cat 18 size 190 For Propane Gas Appliances 569419 H Igniter unit 1 554949...

Страница 21: ...If you require your fire to be serviced please contact Valor Service on 0121 386 6203 and quote the following details a model name and number b appliance serial no To be found below the burner and be...

Страница 22: ...ner compartment so that it rests on the edges at the sides and front Pull the coal forward so that it is immediately behind the front rim of the burner compartment See figure 3 2 Place the rear base c...

Страница 23: ...with a slightly damp cloth and then dry Do not use abrasive cleaners they could scratch the surface Ceramic Coals This product uses a fuel effect pieces containing Refractory Ceramic Fibres RCF which...

Страница 24: ...d to light the pilot the battery may need replacing Details of battery replacement are given further on in this manual Until you can obtain a replacement battery the fire can be lit with a taper as de...

Страница 25: ...Never put any paper or other material on the fire Never add any extra coals above the number stated in these instructions This could cause a safety hazard 7 It should be appreciated that although thi...

Страница 26: ...ears trouble free service Your owner guide aims to improve your understanding and appreciation of your Valor gas fire by providing simple and informative instructions to ensure that you benefit from t...

Страница 27: ...igh standards of safety quality and performance Careful Installation Valor is a Corgi registered company All our gas fires must be installed by a competent Corgi Registered Installer in accordance wit...

Страница 28: ...e using your gas fire and keep for future reference This Owner manual gives sufficient details to enable your gas fire to be operated and maintained However if further information is required our Valo...

Отзывы: