3” Liners
3” min.
Bend
Radius
Terminal Cap
Flashing
2 x 3”
fl
ex
liners—see
Venting Table
for length
allowed
Existing
fi
replace
and
chimney
Typical Vent Installation
See list of approved venting accessories on page 36 of this
manual.
NOTE: Flexible co-linear vent pipes may only be installed
into existing non-combustible solid-fuel burning
fi
replaces
and chimneys.
Vent Location
The vent terminal must be located through the roof. This direct
vent appliance is designed to operate when an undisturbed
air
fl
ow hits the outside vent terminal from any direction.
Check local codes for allowable vertical vent termination.
Venting Table
Maximum vertical height 40 ft (measured to bottom of termination)
Minimum vertical height
10 ft (measured to bottom of termination)
Maximum horizontal run
4 ft (measured center to center of pipe)
Maximum offset angle
45
˚
(sweeping bend to allow for obstructions)
Venting Notes
Where possible, avoid joining
fl
ex pipes. If joints are required,
use a approved connector and seal joints with
RTV high temp
sealant
.
Horizontal offset is permissible to allow for routing around
masonry projections. Avoid bending
fl
ex pipe over a 45 degrees
radius where possible.
20
QUALIFIED
INSTALLER
Venting