Remote Control Operation
•
- Nighttime Setback
Temperature Mode
(Appliance
must be in standby mode; pilot
ignited)
-
The room temperature
is measured and compared to the
Nighttime Setback temperature.
The
fl
ame height is then automati-
cally adjusted to achieve the Night-
time Setback Temperature.
•
- Timer Mode
(Appliance
must be in standby mode; pilot
ignited)
-
The timers P1 and P2
(Program 1, Program 2) each can
be programmed to go ON and OFF
at speci
fi
c times. For instructions
see Timer Programming Mode.
• Brie
fl
y press SET button to scroll
to (fan) mode. Fan and Level
icons
fl
ash.
• Press (large
fl
ame) button to
switch ON and increase fan speed.
• Press (small
fl
ame) button
to decrease fan speed. To turn
OFF fan, press (small
fl
ame)
button until all 4 speed level bars
disappear.
NOTE:
The display shows the set temperature every
30 seconds.
NOTE:
8 seconds after the fan has been set, the
handset will automatically go into temperature
control mode. The fan starts 4 minutes after
the gas opens (from OFF or from pilot) at
maximum speed and goes to the displayed
level after 10 seconds. The fan stops 10
minutes after the gas is OFF or at pilot.
-
Circulating Fan
-
The circulating fan has 4
speed levels from low (1 bar) to high (4 bars).
CIRCULATING FAN OPERATION
(if equipped)
Tip
Set the different parameters when they are
fl
ashing.
T E M P
TIMER
11
OWNER’S
INFORMATION