Installation
Push-on
Connector
Connect Remote Control Receiver
1. Connect the wiring harness to the receiver box,
by pushing the wire connector on to the receiver
circuit board. The plug will only go on one way so
please ensure that the wires are pointing up and the
slot in the board is in line with the tab on the wiring
harness plug.
2. Connect the wires as shown. Please note that the
“L” connectors are diff erent sizes; the smaller one
fi ts to the lower connection and the larger one the
top connection on the top left hand side of the valve.
The other two wire connectors can be fi tted to
either terminal located to the left of the
fl ame control button.
Remote control
receiver
GV34 Valve
Receiver
Push-on Connector
CAUTION
DO NOT USE
a screwdriver or other metallic object to
remove the batteries from the receiver or the handset!
This could cause a short-circuit to the receiver.
CAUTION
DO NOT PUT BATTERIES IN THE REMOTE
CONTROL RECEIVER until the wires are con-
nected to the burner control unit as short-
circuit could result in the destruction of the
electrical components.
3. Remove the remote control receiver lid.
4. Fit four AA 1.5 V
alkaline
batteries. Refi t the lid.
5. Place the remote control
receiver on the base of the
fi replace beside the valve.
6. Fit the 9 V
alkaline
battery to the
handset transmitter.
Remote control operating instructions are on
pages 8–9 of this manual and are supplied with the
remote control kit.
Thermostat Knob
Gas Control Knob
Check ignition spark
The pilot burner and electrode unit are at the left end of
the burner.
Push in the lighting knob and turn it counter-clockwise
through the “IGN” position to “PILOT”. A spark should
fl ash across from the pilot electrode to the pilot burner
shield as shown below.