![Valor 739-72ILN Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/valor/739-72iln/739-72iln_installation-and-owners-manual_3479974015.webp)
Thermocouple
probe must be
in flame
Servicing & Maintenance
Checking Pilot and Burner Flames
A periodic check of the pilot and burner fl ames should
be made. Check after the fi re has been on for at least
30 minutes. The pilot fl ame must cover the tip of the
thermocouple probe. The main burner fl ame pattern will
vary from appliance to appliance depending on the type
of installation and climatic conditions.
The appliance area must always be kept clear and
free from combustible materials, gasoline and other
fl ammable vapors and liquids. Inspect the vent terminal
outdoors regularly to make sure that dirt, snow, insects,
leaves, shrubs, trees do not obstruct it. Examine the
whole vent system regularly. We recommend annually.
Pilot Flame can be seen
on the left side between
logs
Correct fl ame appearance
Pilot fl ame
15