Valor 722AP Скачать руководство пользователя страница 8

8

7.

APPLIANCE

PRE-INSTALLATION

PREPARATION

7.1

Check ignition spark
Before attempting to install, it is worth checking that
the electronic ignition system performs satisfactorily.

7.1.1

Fit the battery to the ignition block located below
the burner tray at the left side (see figure 5).

7.1.2

Rotate the control pivot bracket clockwise as far as it
will go (see figure 6). This should close the ignition
circuit.

Sparks should be seen tracking from the electrode
pin to the thermocouple tip (see figure 7).
If there are no sparks make the following checks.
a)

Check condition of battery and that it is 
correctly fitted.

b)

Check spark gap between electrode wire  and

thermocouple tip (see figure 7).
c)

If a & b are satisfactory, check the ignition 
circuit and components.

7.2

Detach the gas valve and connector unit from the
regulator inlet pipe (see figure 8). Keep the unit
safe.

7.3

Detach the burner unit from the convection box by
removing three screws (see figure 9). Lift out the
burner unit.

       

 Fig. 5 Battery location

 Fig. 6 Control pivot rotation

                   

 Fig.7. Pilot ignition unit

 Fig. 9 Burner attachment points

   

 Fig. 8 Gas valve unit disconnection

f i r e - p a r t s . c o m

Содержание 722AP

Страница 1: ...ity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your building Immediately call your gas supp...

Страница 2: ...supply line installation 9 Convection box installation 10 Gas supply connection 11 Ceramic walls installation 11 Front control linkage installation 11 Ceramic coals installation 13 Operation checks 1...

Страница 3: ...ity of the appliance after installation e g additional mantle etc make sure that the changes conform to the installation requirements in this manual Never attempt to burn paper or any other material i...

Страница 4: ...d in the open position The appliance can be installed in the following constructions 4 1 Solid fuel Non combustible fireplaces As supplied this appliance can be installed as an inset in an existing so...

Страница 5: ...E FROM BASE VISAGE FRONT 40 43 OF HEATER B ADORN FRONT 53 with appliance as supplied see page 4 for Valor Cast Suite application 43 with kit 721CRB Fig 2 Clearances to combustible materials in front...

Страница 6: ...learance kit enclosure 5 SUPPLY GAS Model 722AN is for use only with natural gas Model 722AP is for use only with propane gas The supply pressure must be between the limits shown in section 3 of this...

Страница 7: ...Canopy shield 3 Thread cutting screws for canopy shield 2 Machine screws for front surround fixing or Pack 2 Visage Fire Front contains 1 Fire front surround with sliding control 1 Fire front casting...

Страница 8: ...e thermocouple tip see figure 7 If there are no sparks make the following checks a Check condition of battery and that it is correctly fitted b Check spark gap between electrode wire and thermocouple...

Страница 9: ...t sulfur compounds 8 3 Unions in gas lines should be of ground joint type 8 4 The gas supply line must be sized and installed to provide a supply of gas sufficient to meet the maximum demand of the ap...

Страница 10: ...few inches clear of the fireplace front to allow you to fix the vent connector to the top of the convection box 9 4 Pull the vent connector towards the front of the fireplace and locate the rear slot...

Страница 11: ...wall surfaces visible Fit the wall stamped B at the right side and the wall stamped A at the left side Find out which arrangement the customer requires Explain that the customer can not alter the wall...

Страница 12: ...y to align the bottom fixing holes with those in the convection box Fix the bottom of the casting surround to the convection box with two screws See figure 19 or 20 12 4 Align the hole near the bottom...

Страница 13: ...cess in the burner plaques and touch the ceramic plaques See figure 22 13 2 Place the ceramic front coal in position in front of the base coal Make sure that the side legs of the front coal are fully...

Страница 14: ...d the rear multiple coal It has a square hole underneath Place it centrally behind the front multiple coals The square hole must locate in the square peg in the base coal See figure 26 13 6 Place a si...

Страница 15: ...justed Lower the casting so that it rests on the floor see figure 29 14 3 Check valve control and slide control for proper operation as described in the lighting instructions section further on in thi...

Страница 16: ...ng the guard back Release the springs so that they locate behind the canopy See figure 30 15 2 Visage front Locate the two wires projecting from each side of the guard into the holes in the inner face...

Страница 17: ...ire off and allow it to cool before attempting any cleaning Note that the fire will retain heat for some time after it has been turned off Metal parts Clean the metal parts with a slightly damp cloth...

Страница 18: ...bel 2 Turn the gas valve control counterclockwise as far as it will go shut 3 Move the control slide knob up to Off 4 Wait five 5 minutes to clear out any gas then smell for gas including near the flo...

Страница 19: ...mber It will be helpful if the appliance serial number can also be quoted This is on the chained rating plate visible when the ashpan cover is removed The repair parts are shown in the separate repair...

Страница 20: ...20 Manufactured by HEATING BIRMINGHAM ENGLAND Because our policy is one of constant development and improvement details may vary slightly from those given in this publication Valor Ltd fire parts com...