8
7.
APPLIANCE
PRE-INSTALLATION
PREPARATION
7.1
Check ignition spark
Before attempting to install, it is worth checking that
the electronic ignition system performs satisfactorily.
7.1.1
Fit the battery to the ignition block located below
the burner tray at the left side (see figure 5).
7.1.2
Rotate the control pivot bracket clockwise as far as it
will go (see figure 6). This should close the ignition
circuit.
Sparks should be seen tracking from the electrode
pin to the thermocouple tip (see figure 7).
If there are no sparks make the following checks.
a)
Check condition of battery and that it is
correctly fitted.
b)
Check spark gap between electrode wire and
thermocouple tip (see figure 7).
c)
If a & b are satisfactory, check the ignition
circuit and components.
7.2
Detach the gas valve and connector unit from the
regulator inlet pipe (see figure 8). Keep the unit
safe.
7.3
Detach the burner unit from the convection box by
removing three screws (see figure 9). Lift out the
burner unit.
Fig. 5 Battery location
Fig. 6 Control pivot rotation
Fig.7. Pilot ignition unit
Fig. 9 Burner attachment points
Fig. 8 Gas valve unit disconnection
f i r e - p a r t s . c o m