4
2.
OPTIONS
#775ZCK Zero Clearance Kit
Allows the appliance to be installed into an enclosure
constructed of combustible material
.
The kit must be used
in this form of enclosure
.
Enclosure framing dimensions
suitable for the kit are shown in section 4 of this manual.
Full installation instructions are included with the kit.
#721CRB Clearance Reduction Baffle
Can be used with “Adorn” front. Allows the clearance to
mantle to be reduced to 43” (see figure 2).
# Cast Suite Options
A cast suite can be made up of the following options,
selecting one from each category.
Category (a):
MANT01 – Mahogany Mantle Surround.
MANT02 – Oak Mantle Surround.
Category (b):
HEAR01 – Black Granite Hearth.
Category (c):
CAST02 – Art Nouveau Cast Back.
Category (d):
TILE01 – Butterfly Tile.
TILE02 – Cascade Tile.
TILE03 – Esprit Tile.
TILE04 – Minerva Tile.
TILE05 – Primrose Tile.
TILE06 – Tulip Tile.
3.
GENERAL DATA
This appliance is certified by International Approval
Services for use in Canada and the USA.
This appliance must be installed in accordance with local
codes, if any; if none, follow the current ANSI Z223.1 or
CAN/CGA B149, installation code. Only qualified
licensed or trained personnel should install the appliance.
This appliance is only for use with the type of gas indicated
on the rating plate.
3.1
Venting
This appliance is for connection to an approved 5” metal
vent..
3.2
Ratings
722AN
722AP
Altitude (Ft)
0-4500
Input Max.
(Btu/h)
23,000
Input Min
(Btu/h)
13,780
Manifold
pressure (in w.c.)
3.0
9.15
Max Supply
pressure (in w.c)
10.5
13
Min. Supply
pressure (in. w.c.)
5
11
4.
LOCATION IN THE ROOM
This appliance must not be connected to a chimney flue
serving a separate solid-fuel burning appliance.
Note: The State of Massachusetts requires that any flue damper
must be removed or permanently welded in the open position.
The appliance can be installed in the following
constructions:
4.1
Solid fuel (Non-combustible) fireplaces
As supplied, this appliance can be installed as an inset
in an existing solid fuel type fireplace with a chimney
and 5" dia liner (see fig.1).
The fireplace must be built in accordance with the
national, state provincial or territorial building code
recognised by the authority having jurisdiction, or in
the absence of such a code, in accordance with the
National Building Code of Canada or the National
Fire Protection Association code in the USA The
size of the fireplace recess must be sufficient to
accommodate the appliance as shown in fig.1.
If previously used with for burning solid-fuel, the
chimney must be swept before installation of the
appliance. Both chimney and fireplace must be
checked for soundness before installation of the
appliance. The liner must be a type approved by the
enforcing authority and installed in accordance with
the manufacturer's instructions.
The appliance must installed on a floor which is
sufficiently flat and level to ensure stability. Some
fireplace constructions have a well in the floor at the
back that may need to be filled in.
Though not mandatory, we recommend that carpet,
soft vinyl or other combustible floor coverings are
kept at least 16” from the front of the appliance since
these types of materials may be affected by the radiant
heat output from this appliance.
Clearances
The minimum clearances from any combustible
constructions at the front of the appliance are shown
in fig.2.
These front clearances apply for all installations
(except where used with approved Valor Cast Suite)
.
4.2
Enclosures constructed with combustible materials
#775ZCK Zero clearance kit must be installed where
the appliance is intended to be in an enclosure made
with wood studding or other combustible materials.
The enclosure framing requirements are shown in
figure 3.