Installation on MF28 heaters

—Rear Vent ONLY

1.  Remove Simpson Dura-Vent collar from intake plate 

(8 screws). This piece is no longer required.

2.  Remove entire “L” shaped intake plate and put aside 

for re-use (22 screws). Use care to avoid damaging 

the gasket. Retain the screws for future use.

3.  Remove angled exhaust spigot (8 screws). This piece 

is no longer required. Retain screws for future use.

Exhaust 

collar

NOTE

Co-linear adapter may be installed as a 

rear outlet ONLY.

4.  Install new shorter angled exhaust spigot (

rear vent 

position only

) using 8 screws previously removed. 

Ensure that the gasket is in good condition or re-

place with new gasket.

5.  Re-install intake plate using 11 of the 22 screws 

previously removed on the blank face of the plate. 

Do not screw the face having the inlet hole. Ensure 

that the gasket is in good condition or replace with 

new gasket.

6.  Install new outer co-linear plate over the top of the 

intake plate using remaining 11 screws through both 

plates at the outer perimeter.

You may need to drill 2 small pilot holes or use self-

tapping screws for 2 of the 11 screws.

IMPORTANT:

 Ensure that the round gasket is in 

place between the exhaust spigot 

fl

 ange and the 

outer co-linear plate. Use 6 additional screws pro-

vided to seal the outer plate to the gasketed 

fl

 ange 

of the exhaust spigot.

7.  Connect 3” dia. 

fl

 ex liners directly to their respective 

outer plate collars using hose clamps (included) and 

2 sheet metal screws to prevent the liners to sllip 

from the collars.

8.  Attach the conversion plate “

This 

fi

 replace has been 

converted..

.” label 

to the existing 

fi

 replace

 using 

screws or other mechanical means and store any 

removed parts in back of the existing 

fi

 replace for 

future use.

7

6

5

4

3

2

1

Содержание 556CLA

Страница 1: ...in heater installation manual Notes Venting limitations and restrictors are as per those listed for coaxial venting in the heater installation manual except for the MF24 which uses no restric tors when converted to co linear Existing gaskets can be re used if in good condition If not scrape off old gaskets and glue before install ing new gasket DO NOT double stack gaskets New gaskets can be held in...

Страница 2: ...dditional screws supplied to seal outer plate to gasketed flange of exhaust spigot 6 Re fit the blank plate 7 Connect 3 dia flex liners directly to their respective outer plate collars using hose clamps included and 2 sheet metal screws per liner to prevent the liners to sllip from the collars 8 Attach the conversion plate This fireplace has been converted label to the existing fireplace using scr...

Страница 3: ...ondition or re place with new gasket 5 Re install intake plate using 11 of the 22 screws previously removed on the blank face of the plate Do not screw the face having the inlet hole Ensure that the gasket is in good condition or replace with new gasket 6 Install new outer co linear plate over the top of the intake plate using remaining 11 screws through both plates at the outer perimeter You may ...

Страница 4: ...rs sont les mêmes que celles indiquées aux guides d installation des foyers pour une évacuation coax iale à l exception du foyer MF28 pour lequel les re stricteurs d air ne sont pas requise pour l évacuation colinéaire Les joints d étanchéité existants peuvent être utilisés à nouveau s ils sont en bonne condition Sinon grat tez les résidus de joints et la colle avant de poser de nouveaux joints NE...

Страница 5: ...future 2 Enlevez la plaque d entrée extérieure Conservez le joint s il est en bonne condition 3 Enlevez la buse d évacuation existante le joint devrait être laissé sur le foyer 4 Installez la buse d évacuation colinéaire en réutil isant les vis enlevées à l étape 3 Assurez vous de bien serrer les vis 5 Installez la plaque colinéaire notez l orientation sur le schéma ci contre en réutilisant les jo...

Страница 6: ...s que le joint est en bonne condition ou remplacez le 5 Réinstallez la plaque d évent en L en utilisant 11 des 22 vis retirées précédemment Ne pas vissez le côté ouvert de la plaque Assurez vous que les joints sont en bonne condition ou remplacez les 6 Installez la plaque colinéaire sur le côté ouvert de la plaque en L Vissez la avec la plaque en L sur leur périmètre extérieur à l aide des 11 vis ...

Отзывы: