88
Dimensions, Clearance and Framing
The dimensions, clearances and framing vary with
each applications and with the front trim installed. Refer
to the installation instructions of the front trim chosen
for more information.
Speci
fi
cations
Wall Thickness
The appliance vent is suitable for penetrating a
combustible wall up to 14 inches (36 cm) thick.
A non-combustible wall can be any thickness up to
the maximum horizontal run of vent pipe allowed for
the particular installation—see
Horizontal Termination
Venting Con
fi
gurations
section.
Supply Gas
Heater engine 530ILN/ICN/IRN is used for natural gas
installations.
Heater engine 530ILP/ICP/IRP is used for propane gas
installations.
The supply pressure must be between the limits shown
in the
Ratings
table on the previous page.
The supply connection is 3/8 inch NPT female located
at the left side of the control valve.
The opening for the gas supply line is at the rear left
corner of the appliance.
Controls
The unit is supplied standard with a battery operated,
hand-held remote control and receiver which has the
ability to light the pilot and adjust the gas input of the
unit between the pilot setting and the maximum input.
The pilot light may be left on or turned off with each
use to save energy. The remote control provides full
thermostatic or manual operation with the option of
programming thermostat function between certain
times of the day. Manual operation of the valve is also
possible should the batteries or remote control fail.
Electrical
The unit does not require an electrical power source
unless
fi
tted with an optional circulating fan.
Gas supply connection
3/8” NPT female at valve
Gas line ac-
cess at rear
left corner